home *** CD-ROM | disk | FTP | other *** search
/ Boston 2 / boston-2.iso / DOS / HILFEN / MODEM / MDOC41 / MODEMD41.EXE / MDRBETA.TXT < prev    next >
Text File  |  1992-03-01  |  3KB  |  71 lines

  1.  
  2.  Modem Doctor BBS  (410-256-3631)....Beta Release Modem Doctor 4.01
  3.  
  4.  Whats new in 4.01
  5.  
  6. "Letters....we get letters"...and we read them.
  7.  
  8. This is a beta test version of Modem Doctor for those of you out there who
  9. want only the "latest and greatest" of something. There are several
  10. experimental routines in this version, and due to the fact that there seems
  11. to be a new modem released every week these days, I felt that it would be
  12. best to test it among as many people that wish to give it a try.
  13.  
  14. All of the changes in this are minor, some are cosmetic.
  15.  
  16. 1) Experimental tests
  17.       Setup section -
  18.           The speed of the initial modem diagnostics has been improved
  19.           dramatically.
  20.  
  21.       Regs section -
  22.           The DTR/DSR handshaking test has a new timer routine. Some uarts
  23.           were being interperted with false status, especially on lower
  24.           speed computers.  Normally, DSR will stay high on most modems,
  25.           if it stays low, that should indicate a modem that is off, or a
  26.           bad interconnect cable. (Thanks to Roy Zider for his help).
  27.  
  28.           Some Modems are not employing CCITT V.54 protocol in a manner
  29.           that allows testing of the dynamic handshaking features. A patch
  30.           has been made that should correct this (Thanks to Stu Winokur for
  31.           all his help)
  32.  
  33.       Baud Rate -
  34.           56000 was changed to 57600. According to National Semiconductor's
  35.           Uart Handbook, the top speed is supposed to be 56000 + or -
  36.           2.86%. Well, it seems most comm programs go for the highest
  37.           speed, so they factor in the 1600 cps difference. In actuality,
  38.           your speed could also be 54400 too! At lower speeds the rate of
  39.           error is too low to make a difference. In short, since everyone
  40.           calls it 57600, so will Modem Doctor (sorry NSI).
  41.  
  42.       Interactive Mode -
  43.           This module was re-compiled using the latest version of Borland's
  44.           TASM Macro-assembler. One user has reported that the program
  45.           hangs. I believe the problem is related to the length of time
  46.           that interrupts are held off during screen writes. With the
  47.           widespred use of Extended memory and EGA/VGA autoswitching, this
  48.           could pose a problem.
  49.  
  50.        Loopback Mode -
  51.           Option 3, how to build a plug, is now active in the shareware
  52.           version. Sorry guys, I've been meaning to do this for some time,
  53.           but forgot to remove the compiler directive.
  54.  
  55.        Login (Registered Only)
  56.           Some Comm boards are now being manufactured with addresses just
  57.           above the system board of 100H. Earlier versions of Modem Doctor
  58.           would not log these in. Now you can.
  59.  
  60.  The above are minor fixes. Please take the time to beta-test this version
  61.  and leave your comments on the Modem Doctor BBS at 410-256-3631. If you
  62.  wish to upload this to a BBS, you may..but PLEASE make sure to tell
  63.  everyone that this is a BETA TEST VERSION!
  64.  
  65.  Thanks,
  66.  
  67.  Hank Volpe
  68.  
  69.  
  70.  
  71.