- Not that I want to defend Supra or anything, but I do want to
- command on a couple of points in a previous article.
-
- In article <1992Jul25.131356@aminet.uucp>, barrett@aminet.uucp
- (Keith Barrett) writes:
-
- > 1. Performing a ATZ use to drop DTR/DSR on the old Supra 2400,
- > but doesn't on the new one. This made it easier for UNIX
- > and UUCP users because a DTR drop or ATZ would cause a dataset
- > disconnect - it no longer does. Please put this back!
-
- Have you tried checking the value of the &S command? It controls
- whether DSR is nailed high or tracks the offhook condition.
-
- > 3. When the phone is never answered, the modem returns "NO CARRIER".
- > It should return "NO ANSWER".
-
- Hayes modems do not return NO ANSWER if the phone is never answered,
- unless you've used the "@" (Wait for Quiet Answer) dial modifier. I
- imagine that Supra is probably the same. If you simply dial a
- number without using "@", and it never answers, S7 will expire and
- you get NO CARRIER. That's always been the way it is defined to
- work.
-