home *** CD-ROM | disk | FTP | other *** search
/ Soft 19 / Soft19.iso / win95-rc / win95_04.cab / programs.txt < prev    next >
Text File  |  1996-08-01  |  36KB  |  793 lines

  1.        -----------------------------------------------------------
  2.             Microsoft Windows 95 README for Programs Information
  3.                        August l996            
  4.        -----------------------------------------------------------
  5.  
  6.         (c) Copyright Microsoft Corporation, 1996
  7.  
  8. This document provides complementary or late-breaking information to
  9. supplement the Microsoft Windows 95 documentation.
  10.  
  11. ------------------------
  12. How to Use This Document
  13. ------------------------
  14.  
  15. To view Programs.txt on screen in Notepad, maximize the Notepad window.
  16.  
  17. To print Programs.txt, open it in Notepad or another word processor, 
  18. then use the Print command on the File menu.
  19.  
  20. The phone numbers listed in this document are for use in the United 
  21. States and Canada. If you are outside the U.S. or Canada, you can also 
  22. contact your local hardware or software vendor for more information.
  23.  
  24. -------- 
  25. CONTENTS
  26.  
  27. MS-DOS-BASED AND WINDOWS-BASED PROGRAMS
  28. THIRD-PARTY MEMORY MANAGERS
  29. ---------
  30.  
  31.  
  32. MS-DOS-BASED AND WINDOWS-BASED PROGRAMS
  33. =======================================
  34.  
  35. NOTE: All of the following references to software deal with the 
  36. versions that were available at the time Windows 95 shipped. New 
  37. versions may now be available. For updated information about any 
  38. of the issues described here, contact your software vendor.
  39.  
  40. Error Using Data Access from Microsoft
  41. Office Stardard for Windows 95 version 7.0
  42. ------------------------------------------
  43. If you install Microsoft Office Standard for Windows 95 version 7.0 
  44. on a computer running this version of Windows 95, you will see the 
  45. following error message: "Failure to load expression service" when 
  46. using the Access ODBC driver from Office programs such as Excel or 
  47. Word.
  48.  
  49. To correct this problem, you can obtain the free update of Microsoft 
  50. Office for Windows 95 version 7.0b from Microsoft Product Support. 
  51. To obtain a copy, call the Microsoft Order Desk at (800)360-7561. If 
  52. you are outside the United States, contact the Microsoft subsidiary 
  53. in your area. To locate your subsidiary, call the Microsoft 
  54. International Sales Information Center at (206) 936-8661.
  55.  
  56. Animated Icons
  57. --------------
  58. Windows 95 does not support animated icons.
  59.  
  60. Microsoft MS-DOS Utilities Running Under Windows 95
  61. ---------------------------------------------------
  62. The MS-DOS utilities that are installed into the \Windows\Command 
  63. directory have been enhanced to work with Windows 95. The disk repair 
  64. utilities that shipped with older versions of MS-DOS should not be used 
  65. with Windows 95. Most of the other MS-DOS utilities that worked with 
  66. Windows 3.1 should continue to work with Windows 95, but if they were 
  67. bound to an older version of MS-DOS, you may need to use the SETVER 
  68. command to enable them.
  69.  
  70. The following MS-DOS utility files will be deleted after you upgrade 
  71. from an earlier version of Windows:
  72.     Defrag.hlp
  73.     Mwundel.exe
  74.     Mwundel.hlp
  75.     Networks.txt
  76.     OS2.txt
  77.  
  78. The following MS-DOS utility files will be upgraded after you upgrade 
  79. from an earlier version of Windows:
  80.     Ansi.sys
  81.     Attrib.exe
  82.     Chkdsk.exe
  83.     Choice.com
  84.     Country.sys
  85.     Debug.exe
  86.     Deltree.exe
  87.     Diskcopy.com
  88.     Display.sys
  89.     Doskey.com
  90.     Edit.com
  91.     Ega.cpi
  92.     Fc.exe
  93.     Fdisk.exe
  94.     Find.exe
  95.     Format.com
  96.     Keyb.com
  97.     Keyboard.sys
  98.     Label.exe
  99.     Mem.exe
  100.     Mode.com
  101.     More.com
  102.     Move.exe
  103.     Mscdex.exe
  104.     Nlsfunc.exe
  105.     Scandisk.exe
  106.     Scandisk.ini
  107.     Share.exe
  108.     Sort.exe
  109.     Subst.exe
  110.     Sys.com
  111.     Xcopy.exe
  112.     Defrag.exe
  113.     Drvspace.exe
  114.     Emm386.exe
  115.     Ramdrive.sys
  116.     Readme.txt
  117.     Setver.exe
  118.     Smartdrv.exe
  119.  
  120. Re-installing Programs
  121. ----------------------
  122. If you upgrade your existing Windows 3.1 or Windows for Workgroups 
  123. directory to Windows 95, then you do not need to re-install your 
  124. programs. If you install Windows 95 to a new directory, then you must 
  125. re-install all of your Windows-based programs. Copying files from your 
  126. Windows 3.1 directory to Windows 95 is not sufficient.
  127.  
  128. MS-DOS-Based Programs
  129. ---------------------
  130. Your existing MS-DOS-based programs should run from Windows 95. If you 
  131. experience problems with an MS-DOS-based program, you can set it up to 
  132. run in an MS-DOS environment.
  133.  
  134. To run an MS-DOS-based program in an MS-DOS environment (MS-DOS mode):
  135. 1. Create a shortcut to the MS-DOS-based program.
  136. 2. Right click the shortcut icon, and then select Properties.
  137. 3. Click the Program tab, and then click Advanced.
  138. 4. Make sure that the MS-DOS Mode box is checked.
  139.  
  140. When you run a program in MS-DOS mode, it will force Windows 95 to 
  141. shut down and will load the program in an MS-DOS environment. Note 
  142. that you will not have access to devices that require protected-mode 
  143. drivers. 
  144.  
  145. If you find an MS-DOS-based program slowing down or stopping when it is 
  146. in the background:
  147. 1. Right click the MS-DOS Prompt icon on the taskbar, and then click
  148.    Properties.
  149. 2. Click the Misc tab.
  150. 3. Drag the Idle Sensitivity slider toward Low.  
  151. 4. In the Background area, make sure that Suspend Always is not 
  152.    checked.  
  153.  
  154. Anti-Virus Software
  155. -------------------
  156. Existing Anti-Virus software should be able to detect, but not always 
  157. clean, viruses while running on Windows 95. This depends on where the 
  158. virus was found and how the program chose to clean it. Also, virus 
  159. shields may not be able to see all file activity, and therefore 
  160. could miss some virus activity. It is recommended that you update 
  161. your anti-virus software to a version that was designed to run with 
  162. Windows 95.
  163.  
  164. To contact McAfee for information about their new anti-virus software: 
  165. McAfee BBS:(408) 988-4004, McAfee direct line: (408) 988-3832.
  166.  
  167. To contact Symantec Corporation for information about their anti-virus 
  168. software: (800) 441-7234 or (503) 334-6054. 
  169.  
  170. Disk Repair and Optimization Utilities
  171. --------------------------------------
  172. To make it possible to store long filenames on a FAT volume, it was 
  173. necessary to change the file system for Windows 95. Those changes will 
  174. prevent most existing disk repair and optimization programs from
  175. functioning correctly. Depending on how they function, Windows may 
  176. block them from executing in order to protect the data on your disk. 
  177. This is necessary in a multi-tasking environment to prevent disk 
  178. corruption caused by multiple utilities running simultaneously. It is 
  179. strongly recommended that you upgrade to disk repair software that was 
  180. designed for Windows 95. For more information, contact your software 
  181. vendor.
  182.  
  183. Disk-Compression Utilities
  184. --------------------------
  185. Windows 95 works with most major disk-compression products. However, 
  186. since many of these products come with optimization utilities, it is 
  187. recommended that you upgrade to the version designed for Windows 95. 
  188. For more information, contact your software vendor.
  189.  
  190. Windows 3.1 Shell Enhancements
  191. ------------------------------
  192. Most Windows 3.1 shell replacements will still run on Windows 95, but 
  193. with many limitations because of the taskbar, 32-bit components, and 
  194. the new Windows 95 shell. If you want to continue running one of these 
  195. programs, you should upgrade to a version that was designed to run 
  196. with Windows 95.
  197.  
  198. Major Windows 3.1 shell enhancements this may affect: Norton Desktop, 
  199. PC Tools Desktop, Tabworks, Dashboard, and Direct Access Desktop 1.0.
  200.  
  201. Using UNC Network Names with Existing Software
  202. ----------------------------------------------
  203. There are three ways to assign a network resource in Windows 95.
  204.  
  205. 1. Assign a network resource by using its UNC name. UNC names are 
  206.    in the format \\server\share. Windows 95 defaults to this method.
  207. 2. Assign a local name to the network resource; for example, assign 
  208.    one of your LPT ports to a network printer.
  209. 2. Assign a drive letter to a remote disk drive. This was the default 
  210.    behavior in Windows 3.1 and is still supported in Windows 95.
  211.  
  212. Using a UNC name removes much of the ambiguity of the older method that 
  213. Windows 3.1 used. UNC names tend to be longer than their Windows 3.1 
  214. equivalents and this can cause problems for some programs. If you 
  215. experience such problems, you can revert to the Windows 3.1 method 
  216. of addressing network resources. For more information, look up 
  217. "capturing, printer ports" and "mapping, drive letters" in the 
  218. Windows Help index. 
  219.    
  220. This may affect the following programs: Design CAD 2D for Windows, 
  221. CorelDraw for Windows, Corel Photo Paint 5, ccMail, Quickbooks 3.0, 
  222. Lotus Notes, MS Profit 1.0b.
  223.  
  224. Notes on Specific MS-DOS-Based and Windows-Based Programs
  225. ---------------------------------------------------------
  226. Adaptec EZ-SCSI 3.1: When this program is run with Windows 95, 
  227. you may experience the following product limitations:
  228.  
  229. -  Adaptec EZ-SCSI will not modify your Config.sys and/or 
  230.    Autoexec.bat files like it does under Windows 3.1. To use 
  231.    real-mode device drivers with Windows 95, you will need to run 
  232.    EZ-SCSI for DOS. To do this, start Windows 95, and then when you 
  233.    see the message "Starting Windows 95", choose Command Prompt Only. 
  234.    Your Config.sys and and Autoexec.bat files will be modified 
  235.    automatically as needed.
  236. -  The SCSI Power Management device driver included with Adaptec 
  237.    EZ-SCSI 3.1 is not compatible with Windows 95.
  238. -  The SCSI tape backup package does not support backing up long 
  239.     filenames.
  240.  
  241. For information about Adaptec software products designed specifically
  242. for Windows 95, please contact Adaptec direct at (800) 959-7274 or
  243. (408) 945-8600.
  244.  
  245. Adobe Persuasion: You cannot install Adobe Persuasion version 3.0 
  246. if your Config.sys file is empty or has not been created. This is not 
  247. a problem if you are upgrading over an earlier version of Windows or 
  248. MS-DOS.
  249.    
  250. To create a Config.sys file:
  251. 1. Click the Start menu, click Programs, click Accessories, and then 
  252.    click Notepad.
  253. 2. Type "rem This is a temporary config.sys file."
  254. 3. Click File, and then click Save.
  255. 4. Type C:\Config.sys, and then press ENTER.
  256. 5. Continue to install Adobe Persuasion 3.0.
  257.        
  258. For questions about Adobe Persuasion, call Adobe Systems, Inc.
  259. Customer Service at (800) 833-6687. Outside the United States, call
  260. (206) 622-5500 or the number that came with your program.
  261.  
  262. Alacrity E-Quip: If you have Alacrity E-Quip or E-Quip + release 
  263. 1.33D or earlier, you may experience faxing and/or OCR problems. For 
  264. upgrade information, contact Alacrity at: fax (908) 813-2490, 
  265. BBS (908) 813-2495.
  266.  
  267. Ami Pro v3.01: To run the Ami Pro v3.01 tutorial correctly, you must 
  268. set your Windows 95 taskbar to Auto-Hide. To do this:
  269. 1. Click the Start menu, click Settings, and then click Taskbar.
  270. 2. Make sure the Auto hide option is checked.
  271.  
  272. AST Works: If you have problems with the voicemail program that comes 
  273. with AST Works, you will need to obtain updated files. Those files are 
  274. available on the Windows driver library, which can be ordered 
  275. separately. 
  276.  
  277. Astound 2.x: If you experience printing problems, open the properties
  278. for your printer and turn off EMS spooling.
  279.  
  280. ATM fonts: ATM fonts will not show up on the font list when certain
  281. printer drivers for fax programs are selected as the default. You will 
  282. have this problem with WinFax (all versions), FaxWorks, and older 
  283. Quick Link 2 versions. A substitute TrueType font will be used instead.
  284.  
  285. AT&T Mail Access PLUS: If you use AT&T Mail Access PLUS for DOS or
  286. AT&T Mail Access Plus for Windows (earlier than version 2.7), you need
  287. to upgrade to the latest release of Access PLUS for Windows in order
  288. to work well on Windows 95. With the latest release, you'll get AT&T's
  289. new mail engine, Mail Transport, which eliminates the need for the
  290. Background Mailer TSR that was in earlier releases. To order an Access
  291. PLUS upgrade or to get more information about other AT&T messaging
  292. products and services, call (800) 242-6005 and ask for Department 95.
  293.  
  294. Cheyenne ARCSOLO 3.02: Under Windows 95, ARCSOLO 3.02 cannot connect
  295. to the network drives mapped through the Client for NetWare Networks 
  296. (Nwredir.vxd)and Client for Microsoft Networks (VREDIR) when the 
  297. drives are already mapped. To work around this problem, add the 
  298. following line to the [boot] section of your System.ini file: 
  299.     network.drv=commctrl.dll  
  300.  
  301. NOTE: Any DLL will work; this is a 16-bit dll.
  302.  
  303. ClarisWorks for Windows 3.0 v1: To install correctly, you must run the 
  304. SETUPCW program on disk 2. The Setup program on disk 1 will not install
  305. the program under Windows 95. 
  306.  
  307. Conner Tape Backup: Because of enhancements to the Windows 95 file 
  308. system, which supports long filenames, the Conner tape backup 
  309. program does not work with Windows 95. For information about an 
  310. updated version of this utility, call Conner Peripherals at Conner 
  311. Express, (800) 531-0968; ask for the Conner Backup Executive (CBE). 
  312. Or call Conner's FaxBack system at (408) 456-4903.
  313.  
  314. DragonDictate for Windows: For information about the availability of 
  315. an upgrade that may be compatible with Windows 95, call Dragon Systems 
  316. at (800) 825-5897 or (617) 965-5200.
  317.  
  318. Faxworks v3.0: You may experience problems if your default printer 
  319. name is extremely long, which could prevent the Call Center dialog box 
  320. from appearing. If this happens, shorten the printer name or, if you 
  321. are printing to a network printer, capture the printer port. For 
  322. instructions on how to capture a printer port, see Windows Help.
  323.  
  324. FaxWorks version 3.00f.041: The Advanced AGC option (audio gain control) 
  325. is designed to adjust incoming call voice volume. This option does not
  326. work with Windows 95. Using this option creates a .tmp file in your
  327. Temp directory which gradually grows to fill the disk and cause a
  328. system lockup.
  329.  
  330. Finesse: The Finesse program that was written for Windows 3.1 prevents 
  331. Windows 95 from correctly displaying taskbar buttons. If you use this 
  332. program, buttons representing your running programs will not appear 
  333. correctly on the taskbar. To switch between open programs, press 
  334. ALT+TAB. If you are in the United States, call your local Toshiba 
  335. product support organization for more information. Or you can call 
  336. (800) 999-4273. Outside the United States, call the product support 
  337. number that came with this program.
  338.  
  339. Fonts: Only TrueType fonts can be printed with Windows version 1.0 
  340. printer drivers. If a version 1.0 printer driver is selected, only 
  341. TrueType fonts will be displayed in the font list. WinFax Pro 4.0 is 
  342. the only known shipping program with a Windows 1.0 printer driver. 
  343.  
  344. Frye Computer Systems Statistics Display Rack for NetWare (StatRack): 
  345. To run this program with Windows 95:
  346. 1. Locate a copy of the file Wfwnet.drv dated 7/24/93 or later. This 
  347.    file is included with Windows NT version 3.1 or later, or you can
  348.    contact technical support at Frye Computer Systems.
  349. 2. Copy the Wfwnet.drv file into the Windows directory on your 
  350.    Windows 95 computer.
  351. 3. Add the following line to the [boot] section of your System.ini 
  352.    file, located in the Windows directory:
  353.     network.drv = wfwnet.drv
  354.  
  355. 4. Create a file called Fryenet.ini consisting of the following two 
  356.    lines:
  357.     [network]
  358.     protocol = ipx
  359.  
  360. 5. Copy this file into the Windows directory on the Windows 95 
  361.    computer.
  362.  
  363. Gold Disk Astound v2.0: If you experience problems with embedded OLE
  364. objects, obtain the v2.01 patch from Gold Disk.
  365.  
  366. IBM Client Access/400: You will need a patch to run this program with 
  367. Windows 95. For more information, use the SNDPTFORD command through 
  368. Electronic Customer Support (ECS), and then ask for APAR II08704. Or 
  369. you can call 1-800-274-0015, and then:                                    
  370. 1. Press 1 for support line, then enter your customer number.            
  371. 2. Press 1 for new call.                                            
  372. 3. Press 6 for PTF and ask for APAR II08704.                               
  373.   
  374. IronClad: Do not install older versions of IronClad on the same 
  375. computer as Windows 95. The security features of Ironclad are 
  376. incompatible with the Windows 95 file system.
  377.  
  378. Kyrandia 3 Malcolm's Revenge: If you see an EMS memory error when 
  379. running this game:
  380. 1. Right-click the Malcolm.pif file, click Properties, and then click 
  381.    the Memory tab. 
  382. 2. Change the settings for Expanded Memory and Extended Memory to 4096.
  383. 3. Click Apply, and then change the same settings back to Auto.
  384.  
  385. Lotus Notes: To install Lotus Notes from a network computer, you need 
  386. to map a drive letter to the network computer. To do this, carry out 
  387. the following procedure:
  388. 1. Click the Start button, point to Programs, and then click Windows 
  389.    Explorer.
  390. 2. On the Tools menu, click Map Network Drive.
  391. 3. In the Path box, type the path to the network server, and then 
  392.    click OK.
  393. 4. Click the drive you just mapped, and find the Lotus Notes setup 
  394.    program.
  395. 5. Install Lotus Notes.
  396.  
  397. Lotus Notes Windows Client 3.2: If you are using the NetBIOS interface
  398. over IPX and the NetBEUI protocol stacks, then it is necessary to 
  399. configure the port for NetBIOS using the unit number that properly 
  400. corresponds to that protocol. The default number for the first NetBIOS 
  401. protocol is first set to 0, then any additional NetBIOS interface will 
  402. start at port 7 through 1. It is likely that NetBIOS will use 7 or 6 
  403. if NetBEUI is using 0. To make changes, in the Lotus Notes Windows 
  404. client, click the Tools menu, click Setup, and then click Ports. 
  405.  
  406. Managing your Money v2.0a for Windows: This program uses the 
  407. Calendar.exe, Cardfile.exe, and Clock.exe files that shipped with 
  408. Windows 3.x. If you upgrade over Windows 3.x, all of these features 
  409. will be usable. If you did not upgrade over Windows 3.x you will not 
  410. be able to use the Calendar, Cardfile, or Clock. 
  411.  
  412. MaxSoft-Ocron: Business Card Reader 2.0, ColorFax, ImagePhoto, and 
  413. Wordlinx 2.0 were written for Windows 3.1 and may not work correctly 
  414. under Windows 95. For more information inside the United States, call
  415. MaxSoft-Ocron, Inc. at (510) 252-0200. Outside the United States, call 
  416. the product support telephone number that came with your copy of 
  417. Perceive Personal OCR for Hand Scanners. Or write to the company at 
  418. MaxSoft-Ocron, Inc., 4110 Clipper Court, Freemont, CA 94538, USA.
  419.  
  420. MCS Stereo version 1.05: Because of changes in the Windows 95 
  421. operating system, you cannot switch between standard and enhanced 
  422. environments in MCS Stereo version 1.05. If you do, the mixer controls 
  423. will be disabled. To enable them, close the program, and then reopen 
  424. it. If you are in the United States, contact Animotion Development Corp 
  425. for information about obtaining a version of this program designed for 
  426. Windows 95. Inside the United States: call phone (800) 536-4175 or 
  427. (205) 591-5715; fax (205) 591-5716; technical support (205) 591-5715; 
  428. technical support BBS (205) 591-5795. Outside the United States, call 
  429. the product support number that came with your copy of MCS Stereo.
  430.  
  431. Media Blitz 3.0:  After installing Media Blitz 3.0, you must restart 
  432. your computer before you run the program to enable Windows 95 to pick 
  433. up changes made by the setup program. 
  434.  
  435. Menuworks Total Security:  The security features of this product 
  436. are incompatible with the Windows 95 file system. It is strongly 
  437. recommended that you remove this software before installing Windows 95.
  438.  
  439. Microprose 1942 Gold: This program uses the version of Command.com 
  440. located in your \Dos directory. Older versions of Command.com will 
  441. not run with Windows 95. To run 1942 Gold with Windows 95, copy 
  442. Command.com in your \Windows directory over the version in your 
  443. \Dos directory.
  444.  
  445. MicroHelp Compression Plus 4.0: If you have problems installing
  446. Compression Plus on Windows 95, try carryout out the following
  447. procedure.
  448. 1. Add the word progman to the end of the SHELL= line in your
  449.    System.ini file. For example:
  450.  
  451.    shell=explorer.exe progman
  452.  
  453. 2. Restart your computer, and then reinstall MicroHelp Compression.
  454. 3. Change your System.ini file back to its original setting.
  455.  
  456. Microsoft Client for NetWare, running with Dial-Up Networking: This
  457. may cause some problems with Pagemaker 5.0 and Quark Xpress 3.3. 
  458. QuarkXpress 3.3 may not work properly when only the DIAL-UP\IPX 
  459. components are loaded but the computer is not connected to a valid 
  460. network. If you see the message "Unable to access network [116]" when 
  461. starting QuarkXpress 3.3, remove the DIAL-UP\IPX components or connect 
  462. to a valid network. This problem will be fixed in QuarkXPress 3.32.
  463.  
  464. Microsoft FORTRAN 5.1: If you want to create QuickWin applications 
  465. using Microsoft FORTRAN 5.1 running on Windows 95, you need to either 
  466. delete or comment out the following line in the Fl.def file:
  467.  
  468.      APPOADER '___MSLANGLOAD'
  469.  
  470. After you remove this line, you need to recompile any QuickWin programs
  471. that were built with version 5.1 in order for these programs to run
  472. in Windows 95.
  473.  
  474. Microsoft FORTRAN PowerStation: Microsoft FORTRAN PowerStation for
  475. MS-DOS and Windows is designed to work optimally under Windows 3.1.
  476. If you use Microsoft FORTRAN PowerStation with Windows 95, graphics
  477. programs that you compiled using the program will fail when you run
  478. them. A runtime error appears instead of the usual graphics output.
  479.  
  480. A patch is available to solve this problem. If you are still using
  481. version 1.0 instead of version 1.0a, you need to obtain an updated
  482. version of the program. To determine which version you are running,
  483. change to the Bin directory, and then run Link.exe. If you are
  484. running version 1.0a, the text "Version 1.0F" should appear.
  485.  
  486. To obtain the patch, contact Microsoft product support services at 
  487. the number listed in your documentation. Or, if you live in the 
  488. United States or Canada, call (206) 635-7015. You can also download 
  489. the file Fpsfix.exe from the Microsoft Software Library (MSL) on 
  490. CompuServe or on Anonymous FTP.
  491.  
  492. Microsoft Mail 3.2 and Microsoft Schedule+: Microsoft Exchange is
  493. an upgrade to Microsoft Mail v3.2 and replaces many of the older 
  494. components. For this reason, Microsoft Mail v3.2 will not work if you 
  495. have installed Microsoft Exchange. Also, the Windows 3.1 version of 
  496. Microsoft Schedule+ will not be able to use Exchange to send Email. 
  497.  
  498. Microsoft Visual C++ version 1.5: With the Windows 95 interface 
  499. enhancements, dialog boxes in Visual C++ version 1.5x may appear in 
  500. different screen locations than on Windows 3.1 or Windows NT. When 
  501. you are debugging a program under the Visual C++ environment, it is 
  502. recommended that you not minimize the Visual C++ main window. This 
  503. may cause debug dialog boxes to be displayed off-screen, which would
  504. result in your not being able to maximize the Visual C++ main window.
  505.  
  506. Microtek ScanWizard 2.0b7: If you have problems installing this
  507. program, try carrying out the following procedure:
  508. 1. Add the following line to the [Compatibility] section of your
  509.    Win.ini file:
  510.  
  511.    DSHELL=0x00400000
  512.  
  513. 2. Restart your computer, and then re-install Microtek ScanWizard.
  514. 3. Remove this line from your Win.ini file.
  515.  
  516. Nickelodeon Director's Lab: Some messages may display at the end of
  517. the setup program. You will need to close the setup program manually. 
  518. This does no harm, because Director's Lab has already been installed. 
  519. After the setup program has added the new shortcuts, you may see the 
  520. following message: "Setup Message: Script or DLL has been corrupted. 
  521. Unable to load dialog template: 'mscuistf.dll: 2'." If this message 
  522. appears, follow these steps.
  523. 1. Press CTRL+ALT+DEL.
  524. 2. Click the Director's Lab setup program, and then click End Task.
  525.  
  526. Norton Backup: Windows 95 requires new settings for this program. 
  527. Before you run Norton Backup, delete the Nbackup.pif file located in 
  528. the Norton Backup directory.
  529.  
  530. Office Accelerator: Because there is no Print Manager, Office 
  531. Accelerator will not load using the Office Accelerator menus. Instead, 
  532. configure your printers by clicking the Start menu, clicking Settings, 
  533. and then clicking Printers.
  534.  
  535. Paint Shop Pro v2.0: You will not be able to use this program to draw 
  536. capture areas inside 32-bit programs, because 16-bit programs do not 
  537. see mouse movements over 32-bit programs. All other mouse capture 
  538. methods will still work, and this will continue to work with 16-bit 
  539. programs. 
  540.  
  541. PCTools Versions 7 Through 9: Shortcuts will not be created during 
  542. installation of PCTOOLS versions 7 through 9 on Windows 95. To create 
  543. shortcuts after installation:
  544. 1. Click the Start menu, and then click Run.
  545. 2. Type Cpsdos.grp, and then press ENTER.
  546.  
  547. PCTools will be added to your Programs folder. For the shortcuts to 
  548. work, you must add the PCTOOLS directory to the PATH.
  549.  
  550. Because of changes to the Windows 95 file system, these disk utilities 
  551. will not work correctly with long filenames. For information about 
  552. purchasing disk utilities that were designed for Windows 95, contact 
  553. Symantec.
  554.  
  555. Personal Oracle 7.1 for Windows 3.1: This program cannot be installed
  556. on   Windows 95  because it requires a Win32s .dll that is no longer
  557. used. For   information about obtaining an updated version for Windows
  558. 95, call   Oracle Corporation at (415) 506 7000 or contact your local
  559. Oracle office.
  560.  
  561. QuarkXPress 3.3: You may experience the following problems:
  562. - Out-of-memory error. Upgrading to QuarkXPress 3.32 should solve the 
  563.   problem. You can download a patch from CompuServe, or contact Quark 
  564.   directly.
  565. - QuarkXpress 3.3/3.31x library windows may fail to display control box
  566.   and menu items, rendering it impossible to resize or close library
  567.   files. This problem will be corrected in QuarkXpress 3.32
  568. - The QuarkXPress installer may stop at 99% complete when installing on 
  569.   some Windows 95 computers. To properly complete the installation
  570.   process, select the Continue button.
  571.  
  572. Quickbooks 2.0: If you experience problems running Quickbooks 2.0 
  573. with Windows 95, add the following entry to the [Compatibility] 
  574. section of your Win.ini file:
  575.     QBW=0x08000000
  576.  
  577. Quickbooks 3.0: Before you minimize Quickbooks, be sure to register 
  578. the product. If you have already minimized it and are experiencing 
  579. problems running Quickbooks 3.0, delete the Qbw.ini file in your 
  580. Quickbooks directory. 
  581.  
  582. Quicken: If you configured Quicken to use a printer other than the 
  583. system default printer or to use custom fonts, you will lose these 
  584. settings after upgrading to Windows 95. After Windows 95 is installed, 
  585. you can use Quicken to restore these settings.
  586.  
  587. Rumba Office 2.0: The shared folders functionality is not functional
  588. in Windows 95 and will cause installation problems if selected. To 
  589. turn off this feature, when installing Rumba:
  590. 1. Select Custom.
  591. 2. Select AS/400.
  592. 3. Make sure the check box titled Shared Folders And Client API's is 
  593.    not checked.
  594. 4. Continue the installation.
  595.  
  596. Splice 2.0: You may encounter a General Protection Fault if you try 
  597. to create an optimal palette with some video files. This problem has 
  598. been fixed by Asymetrix in the most recent version (now called Digital 
  599. Video Producer). An free upgrade is available from Asymetrix for all 
  600. registered Splice users. For more information, contact Asymetrix 
  601. Technical Support at 206-637-1600.
  602.  
  603. SuperPrint: Because of changes to the Windows operating system, 
  604. Version 2.0 of SuperPrint (which includes SuperQue) does not work 
  605. with Windows 95. For more information about SuperQue 95, call 
  606. (800) 366 7494.
  607.  
  608. Talk-To Plus: For information about the availability of an upgrade 
  609. that may be compatible with Windows 95, call Dragon Systems at 
  610. (800) 825-5897 or (617) 965-5200.
  611.  
  612. The 7th Guest: If you are running The 7th Guest with a Pro Audio 
  613. Spectrum 16 sound card, you will either need to enable and use the 
  614. Sound Blaster compatibility mode, or configure your Pro Audio Spectrum 
  615. card to IRQ 5 and DMA 3.
  616.  
  617. Timeline: You may have problems running existing macros with Timeline. 
  618. Timeline tries to use window handles that it has already freed and may 
  619. cause an error. For information about program updates, contact the 
  620. vendor.
  621.  
  622. Typestry 2.0: If you experience problems running Typestry 2.0, you
  623. need to obtain a patch from Pixar, Inc. Call the product support number
  624. that came with your software. You may also have problems using Typestry
  625. to print to a PostScript printer under Windows 95. The workaround is
  626. to use a non-PostScript or UniDrive printer.
  627.  
  628. Ultima VI/Wing Commander CD: Because Windows 95 does not support the 
  629. JOIN command, you will need to run the Ultima VI/Wing Commander CD 
  630. from your hard drive. The procedure for doing this is outlined below 
  631. and in the documentation for this CD game. You will need to copy all 
  632. programs to your hard drive, and then run Install.exe to configure the 
  633. program. You will need approximately 13 MB of space for Wing Commander 
  634. and 5 MB of space for Ultima VI.
  635.  
  636. To copy all files for either Wing Commander or Ultima VI:
  637. 1. Click the Start menu, click Programs, and then click Explorer.
  638. 2. Double click your CD-ROM drive.
  639. 3. Click the icon for the folder you want to move, and then drag it 
  640.    to the icon for your hard disk.
  641. 4. Run the install program from your hard drive to configure the 
  642.    proper video and sound options.
  643.  
  644.  
  645. XtraDrive: You must load SETVER before the file Xtradrv.sys loads. 
  646.  
  647. YiJaak Graphic Suite: Some problems may occur when running Smuggler.exe 
  648. with Windows 95. To avoid problems:
  649. - Use the screen capture utility for only short periods of time.
  650. - Periodically restart your computer to regain system resources when 
  651.   running Smuggler.exe for long periods of time.
  652.  
  653. For information about obtaining a Windows 95 version of this program, 
  654. in the United States call Inset Systems, Inc., at (800) DR-INSET. 
  655. Outside the United States, call (203) 740-2400.
  656.  
  657. THIRD-PARTY MEMORY MANAGERS
  658. ===========================
  659.  
  660. 386MAX 7.0
  661. ----------
  662. Windows 95 removes the following lines from the Config.sys file during
  663. Setup:
  664.     Device=\386MAX\ExtraDOS.max pro=\386MAX\ExtraDOS.pro
  665.     Install=\386MAX\ExtraDOS.max
  666.  
  667. If Windows 95 fails to start after Setup, try carrying out the
  668. following procedure:
  669. 1. Refer to the \Manual\Readme.txt file (packaged with 386MAX) about
  670.    specific software and hardware incompatibilities with the 386MAX
  671.    software.
  672. 2. Run the MAXIMIZE program, and then follow these steps:
  673.    a. After MAXIMIZE restarts your computer for the first time, press 
  674.       F8 when you see the "Starting Windows 95" message. 
  675.    b. Choose Safe Mode Command Prompt Only. 
  676.    c. Open your Config.sys file by using any text editor, such as 
  677.       MS-DOS Editor, and remove the following lines:
  678.     Device=\386MAX\ExtraDOS.max pro=\386MAX\ExtraDOS.pro
  679.     Install=\386MAX\ExtraDOS.max
  680.  
  681.    d. Open your 386max.pro file, which is located in the directory 
  682.       where 386MAX is installed, and remove the following lines if 
  683.       they exist:
  684.     Line beginning with "PRGREG"
  685.     Line beginning with "HPDAREG"
  686.     Line beginning with "STACKREG"
  687.  
  688.    e. Restart your computer.
  689.    f. When you see the "Starting Windows 95" message, press F8.
  690.    g. Choose Command Prompt Only. MAXIMIZE should continue setting up.
  691.    h. Each time the computer restarts, repeat steps f and g until
  692.       MAXIMIZE has finished.
  693.  
  694. NOTE: If you see the message "ExtraDOS Error," click OK.
  695.  
  696.  
  697. 386MAX v7.02, BLUEMAX v7.02, and later versions
  698. --------------------------------------------
  699. Version 7.02 and later of BLUEMAX and 386MAX were designed to run with
  700. Windows 95, and a free update can be obtained from Qualitas, Inc. at the
  701. following locations:
  702.  
  703. Qualitas BBS - Dial (301) 907-8030
  704. CompuServe - PCVENA, GO QUALITAS
  705. America OnLine - Keyword Qualitas
  706. Qualitas Customer Service - (301) 907-7400
  707.  
  708. If you have version 7.02 or later of these memory managers, you do not need to
  709. follow the work-arounds described in the following sections.  However, if you
  710. install Windows 95 on a system that already has a later version of BLUEMAX or
  711. 386MAX, you should run the MAXIMIZE utility to reinstall the ExtraDOS utility
  712. that Windows 95 removes during setup.
  713.  
  714.  
  715. BLUEMAX 7.0
  716. -----------
  717. Windows 95 removes the following lines from the Config.sys file during
  718. Setup:
  719.     Device=\BlueMAX\ExtraDOS.max pro=\BlueMAX\ExtraDOS.pro
  720.     Install=\BlueMAX\ExtraDOS.max
  721.  
  722. If Windows 95 fails to start after Setup, try the following procedure:
  723. 1. Refer to the \Manual\Readme.txt file (packaged with BlueEMAX) about
  724.    specific software and hardware incompatibilities with the BlueMAX
  725.    software.
  726. 2. Run the MAXIMIZE program, and then follow these steps:
  727.    a. After MAXIMIZE restarts your computer for the first time, press 
  728.       F8  when you see the "Starting Windows 95" message.
  729.    b. Choose Safe Mode Command Prompt Only. 
  730.    c. Open your Config.sys file by using any text editor, such as 
  731.       MS-DOS Editor, and remove the following lines:
  732.     Device=\BlueMAX\ExtraDOS.max pro=\BlueMAX\ExtraDOS.pro
  733.     Install=\BlueMAX\ExtraDOS.max
  734.  
  735.    d. Open your Bluemax.pro file, which is located in the directory 
  736.       where BlueMAX is installed, and remove the following lines if 
  737.       they exist:
  738.     Line beginning with "PRGREG"
  739.     Line beginning with "HPDAREG"
  740.     Line beginning with "STACKREG"
  741.  
  742.    e. Restart your computer.
  743.    f. When you see the "Starting Windows 95" message, press F8.
  744.    g. Choose Command Prompt Only. MAXIMIZE should continue setting up.
  745.    h. Each time the computer restarts, repeat steps f and g until
  746.       MAXIMIZE has finished.
  747.  
  748. NOTE: If you see the message "ExtraDOS Error," click OK.
  749.  
  750. NETROOM version 3
  751. -----------------
  752. Before setting up Windows 95, verify that CACHECLK is not being 
  753. loaded in the Autoexec.bat file. Windows 95 Setup will fail with 
  754. CACHECLK loaded.
  755.  
  756. After Setup, if Windows 95 fails to start:
  757. 1. Refer to the \Manual\Readme.txt file (packaged with Netroom) about 
  758.    specific software and hardware incompatibilities with the NETROOM 
  759.    software.
  760. 2. Run the CUSTOMIZE program.
  761.  
  762. QEMM 7.01 - 7.5
  763. ---------------
  764. Windows 95 removes the following drivers from the Config.sys file 
  765. during Setup:
  766.     Dosdata.sys
  767.     Dos-up.sys
  768.     St-dbl.sys   (7.01-7.04)
  769.     St-dspc.sys  (7.5)
  770.  
  771. After Setup, if Windows 95 fails to start:
  772. 1. Refer to the Manual\Technotes\Readme.txt file (packaged with 
  773.    QEMM) for information about specific software and hardware 
  774.    incompatibilities with QEMM software.
  775. 2. Check Stealthing Options. Try changing ST:M to ST:F on the 
  776.    Qemm386.sys line in the Config.sys file, and then restarting your 
  777.    computer. If that doesn't work, try removing the ST:M or ST:F 
  778.    completely from the Qemm386.sys line in the Config.sys file and 
  779.    then restarting your computer.
  780. 3. Run QSETUP and turn off DOS-UP, Quickboot, and Stealthing Options 
  781.    (see above). QSETUP will recommend running OPTIMIZE.
  782. 4. Run the OPTIMIZE program. (NOTE: If DOS-UP or Stealthing are 
  783.    enabled in QSETUP, then OPTIMIZE will add them to the Config.sys 
  784.    file. Currently, Windows 95 may fail to start with Dosdata.sys and 
  785.    Dos-up.sys installed in the Config.sys file.)
  786.  
  787. Dosdata.sys, a portion of the DOS-UP features of QEMM, causes the 
  788. Windows 95 multi-boot feature to attempt to start Windows 95 even 
  789. after you select the Previous Version Of MS-DOS option. To bypass 
  790. this situation, press F4 during the second appearance of "Starting 
  791. Windows 95." To correct this problem permanently, remove Dosdata.sys 
  792. and Dos-up.sys from the Config.dos file.
  793.