home *** CD-ROM | disk | FTP | other *** search
/ OS/2 Professional / OS2PRO194.ISO / os2 / com / utils / pm2you / pm2you.inf (.txt) < prev    next >
OS/2 Help File  |  1993-10-19  |  19KB  |  451 lines

  1.  
  2. ΓòÉΓòÉΓòÉ 1. Why you should register this product ΓòÉΓòÉΓòÉ
  3.  
  4. This program is released as shareware. This means that you have the software 
  5. for a trial period, and after a reasonable evaluation time, you register the 
  6. product by paying a fee to the author, if you find the program of use.  Some 
  7. limitations on how you can use this program exists (see the section Important 
  8. license information for more about this).  By registering this product you 
  9. support the further development of this program.
  10.  
  11.  You will get the following benefits if you register: 
  12.  
  13. o You will get the most recent versions of PM2You, OS2You and M2Zmodem. 
  14.  
  15. o You will get rid of the introduction screen with the delay, when starting the 
  16.   program. 
  17.  
  18. o You will be sleeping good tonight, without any bad conscience haunting you... 
  19.  
  20.  
  21. ΓòÉΓòÉΓòÉ 2. Introduction ΓòÉΓòÉΓòÉ
  22.  
  23. Introduction 
  24.  
  25.  PM2You is an add-on product for OS2You that allows you to remote control your 
  26. OS/2 Text, OS/2 Presentation Manager, DOS Text and graphics and MS Windows 
  27. programs.  Please also read the OS2YOU.INF help file for help about OS2You.
  28.  
  29.  PM2You will work with OS/2 1.2 or higher (including OS/2 2.x.  When running 
  30. under OS/2 2.x a special 32-bit module will be loaded to enable some special features).
  31.  
  32.  Included in this package are several different programs except the programs 
  33. described in the OS2YOU.INF documentation. 
  34.  
  35. PM*.*               PM2You graphics add-on 
  36.  
  37. WIN*.*              WinTerm Windows graphics terminal emulator with mouse 
  38.                     support 
  39.  
  40. TERM2*.*            Terminal/2 PM graphics terminal emulator with mouse support 
  41.  
  42. LANTERM2.*          LanTerm2 OS/2 Full screen graphics terminal emulator 
  43.  
  44. ZIP.DLL             Compression module used by OS2You, PM2You, LanTerm2 and 
  45.                     Terminal/2 
  46.  
  47. FTP*.*              File transfer modules used by Terminal/2 and OS2FTP 
  48.  
  49. OS2FTP*.*           File transfer utility 
  50.  
  51.  
  52. ΓòÉΓòÉΓòÉ 3. Installation ΓòÉΓòÉΓòÉ
  53.  
  54. Installation 
  55.  
  56.  To install the different program run the INSTALL-program included.  It will 
  57. copy the correct files for you, modify your CONFIG.SYS file and build PM 
  58. icons/objects for the different applications.  PM2You is running on top of 
  59. OS2You, and thus you must have OS2You running to use PM2You.
  60.  
  61.  For more information about use of OS2You, please read the OS2YOU.INF file.
  62.  
  63.  Note that it is extremely important that the *.DLL files are copied into a 
  64. directory specified in your LIBPATH statement.  Even if you have the "." 
  65. included in your LIBPATH statement, it is not sufficient to leave the *.DLL 
  66. files into the current directory.
  67.  
  68.  It is also important that the sub-directory is included in the PATH and DPATH 
  69. statements of your CONFIG.SYS file.  It is not sufficient that these 
  70. environment variables are set in the session just before loading OS2You.
  71.  
  72.  If you let the INSTALL program modify your CONFIG.SYS file the above 
  73. configurations should be made automaticly.
  74.  
  75.  It is important that both OS2You and the modems are set to be completely 
  76. transparent.  This means that they must be communicating with 8 databits and 
  77. that Xon/Xoff handshaking is turned off.
  78.  
  79.  There are some optional configuration parameters in PM2You that you can set. 
  80. This shouldn't be necessary normally, but if you experience problems you can 
  81. either change these settings when running PM2You remotely by selecting 
  82. "Settings" in the PM2You window.  You can also start PM2You in a special 
  83. configuration mode by just issuing the command "PM2You".
  84.  
  85.  Software PAD feature added in Terminal/2.
  86.  
  87.  
  88. ΓòÉΓòÉΓòÉ 4. Performance tuning PM2You ΓòÉΓòÉΓòÉ
  89.  
  90. Performance tuning PM2You 
  91.  
  92.  To increase performance please consider the following options:
  93.  
  94.  Do not use a bitmap (picture) as desktop background.
  95.  
  96.  Ensure that your desktop background (and other large color areas) are drawn 
  97. with solid colors and not dithered.
  98.  
  99.  Run at the lowest acceptable screen resolution (however note that decreasing 
  100. the amount of colors does not improve performance significantly, you can use 
  101. 256 colors without much performance penalty).
  102.  
  103.  Using modems with built in data compression (MNP5 or V.42") will not improve 
  104. performance as the PM2You data stream is very efficient (but error correcting 
  105. modems MNP4 or V.42 should be considered as the PM2You data stream is sensitive 
  106. for transmission errors).
  107.  
  108.  
  109. ΓòÉΓòÉΓòÉ 5. Starting PM2You ΓòÉΓòÉΓòÉ
  110.  
  111. Starting PM2You 
  112.  
  113.  After logging in to OS2You getting an OS/2 Command Prompt, you just issue the 
  114. command PM and press Enter.  After a while your terminal should switch to 
  115. graphics mode and present your PM Desktop.
  116.  
  117.  It is possible to let a user go directly to the PM Desktop by specifying 
  118. PM.EXE as the "Shell command" in the user profile.
  119.  
  120.  PM2You is used exactly as OS2You with the same keyboard mappings. Especially 
  121. note Esc-Tab (or Shift-Esc-Tab if you use LanTerm(2)) for accessing the task 
  122. list. 
  123.  
  124.  
  125. ΓòÉΓòÉΓòÉ 6. Using PM2You with DOS Windowed sessions ΓòÉΓòÉΓòÉ
  126.  
  127. Using PM2You with DOS Windowed sessions 
  128.  
  129.  When using PM2You, you can start and select a DOS Windowed session and use it 
  130. as usual.  Remember that you should ensure that the KBFILTER.COM program 
  131. (included) is loaded (preferable in your AUTOEXEC.BAT).  You can run both DOS 
  132. Text and DOS Graphics applications in a windowed session. Mouse input is not supported.
  133.  
  134.  This is not applicable for OS/2 1.x installations. 
  135.  
  136.  
  137. ΓòÉΓòÉΓòÉ 7. Using PM2You with Seamless Windows sessions ΓòÉΓòÉΓòÉ
  138.  
  139. Using PM2You with Seamless Windows sessions 
  140.  
  141.  When using PM2You, you can start any seamless MS-Windows session and use it as 
  142. usual (Seamless means that it must run on top of the PM Desktop and not Full 
  143. Screen).  You can use it as usual except that keyboard acceleration (shortcuts) 
  144. does not work (use mouse input instead).
  145.  
  146.  This is not applicable for OS/2 1.x installations. 
  147.  
  148.  
  149. ΓòÉΓòÉΓòÉ 8. Using PM2You with OS/2 Windowed sessions ΓòÉΓòÉΓòÉ
  150.  
  151. Using PM2You with OS/2 Windowed sessions 
  152.  
  153.  When using PM2You with OS/2 1.x, you can start any OS/2 Windowed session and 
  154. use it as usual.  Mouse is not supported 
  155.  
  156.  This does not work with OS/2 2.x installations.  In OS/2 2.0 OS/2 Windowed 
  157. sessions can be started, but there is no possibility for any input to the 
  158. session. 
  159.  
  160.  
  161. ΓòÉΓòÉΓòÉ 9. Terminating PM2You ΓòÉΓòÉΓòÉ
  162.  
  163. Terminating PM2You 
  164.  
  165.  To terminate the PM2You session, you bring up the task list and select "PM2You 
  166. Remote Access Facility" in the task list and end it by pressing the right mouse 
  167. button (or Shift-F10) and select "Close".  You can also bring up the PM2You 
  168. status window and double click on the system menu (or press Alt-F4). 
  169.  
  170.  
  171. ΓòÉΓòÉΓòÉ 10. Terminal emulators ΓòÉΓòÉΓòÉ
  172.  
  173. Terminal emulators 
  174.  
  175.  To use PM2You you will need terminal emulators specially written for this 
  176. purpose.  There are currently terminal emulators available for OS/2 Full Screen 
  177. (LanTerm2), OS/2 Presentation Manager (Terminal/2) and Windows 3.x (WinTerm).
  178.  
  179.  LanTerm2 only runs in VGA resolution.  This means that if your host system is 
  180. running at a higher resolution than VGA you will only see the lower left part 
  181. of the display area.  LanTerm2 does not support mouse. LanTerm2 supports 
  182. communication over all available devices (Asynchronous, Named Pipes and NetBIOS)
  183.  
  184.  Terminal/2 can be used with any resolution.  Scaling is done automaticly 
  185. (compressing/stretching) so the whole host systems display area is fitted into 
  186. the terminal window size selected for Terminal/2.  By pulling in the border 
  187. line of Terminal/2 you can resize it to any size you want.  Note that you can 
  188. only resize the Terminal/2 window size in this way when you are running in 
  189. PM2You Graphics mode.  When Terminal/2 is maximized it will select a window 
  190. size so the action bar menues will fit into the display as well. This means 
  191. that the terminal display area is slightly smaller than the host display area. 
  192. By selecting "Maximize hides menues" in the Special->Settings dialog you can 
  193. alter this behaviour so Terminal/2 will select a window size so the active 
  194. display area covers all the screen and the action bar menues are placed 
  195. invisible just above the upper border of the screen.
  196.  
  197.  Terminal/2 have full mouse support.  The shape of the mouse pointer indicates 
  198. different statuses of Terminal/2.  A hour-glass (or clock symbol) indicates 
  199. that an update is in progress.  An exclamation mark symbol indicates that a 
  200. transmission error occured and in addition the speaker will beep.  A stop 
  201. symbol indicates a fatal error.  Regardless of the pointer shape, you can 
  202. always use the mouse to issue mouse commands to the remote host (i.e a 
  203. clock-symbol doesn't mean you must wait to perform your commands).
  204.  
  205.  Terminal/2 supports communication over all available devices (Asynchronous, 
  206. Named Pipes and NetBIOS)
  207.  
  208.  WinTerm currently have a fixed window size calculated by the font size 
  209. selected in the configuration.  Thus by selecting the large font you will also 
  210. get a larger window for the graphics emulation.  It is not possible to change 
  211. the window size dynamically.  This is to be changed in a later release of WinTerm.
  212.  
  213.  WinTerm have full mouse support.  WinTerm currently only supports graphics 
  214. emulation over Asynchronous devices and not pipes or NetBIOS 
  215.  
  216.  
  217. ΓòÉΓòÉΓòÉ 11. Known limitations/errors ΓòÉΓòÉΓòÉ
  218.  
  219. Known limitations/errors
  220.  
  221.  This software is continously being improved.  If you find any errors in this 
  222. software we would appriciate reports about this.  In this release there are 
  223. some known limitations:
  224.  
  225.  Keyboard input does not work in OS/2 Windowed sessions in OS/2 2.0.
  226.  
  227.  LanTerm2 only works with VGA resolutions at 640*480 with 16 colors.  Thus if 
  228. you have a 256 color display on the host, colors will be distorted.
  229.  
  230.  The PM2You data stream is sensitive for transmission errors.  If a 
  231. transmission error occurs incompletely updated horizontal areas will be 
  232. noticed.  You can manually request a repaint of all the screen by pressing 
  233. Shift-Esc Space in LanTerm2 or selecting Screen refresh in the menues in 
  234. Terminal/2 or WinTerm.
  235.  
  236.  The type of mouse cursor is not modified on the terminal.  In Terminal/2 the 
  237. mouse cursor will not reflect the status of the host.  The hourglass (or clock) 
  238. symbol will be showed during screen updates and the Exclamation mark will be 
  239. showed when a transmission error is detected.
  240.  
  241.  WinTerm only works with asynchronous communication for graphics modes. NetBIOS 
  242. and Named Pipes are not supported for graphics in WinTerm.  Terminal/2 and 
  243. LanTerm2 support Asynchronous devices as well as Named Pipes and NetBIOS. 
  244. Mailslot and broadcast (one-to-many slave terminals) communication is not 
  245. tested, but should work.
  246.  
  247.  WinTerm can not handle more than 16 colors currently.  This means that the 
  248. host must not use more than 16 colors, or the output will not be readable.
  249.  
  250.  When running Terminal/2 on a 256 color display with a 16 color host, colors 
  251. will not be mapped correctly.  Output will be readable, but with wrong colors.
  252.  
  253.  
  254. ΓòÉΓòÉΓòÉ 12. Release log ΓòÉΓòÉΓòÉ
  255.  
  256. Release log 
  257.  
  258.  Bugs and improvements not described elsewhere are documented in this section. 
  259.  
  260. 1.0       First release 
  261.  
  262. 1.1       Corrected keyboard input error in system "E"ditor. (REP=1)
  263.  
  264.            OS/2 1.3 compatibility is now working. (WM_NULL)
  265.  
  266.            Color palette fixed in PM2You (256 color mode), Terminal/2 and WinTerm.
  267.  
  268.            NetBIOS operation fixed in OS2You and Terminal/2.
  269.  
  270.            Operation with some third party COM drivers (like SIO.SYS) is improved.
  271.  
  272.            Built in file transfer over Named Pipes restores itself correctly.
  273.  
  274.            Terminal/2 hangup over Named Pipes closes pipe.
  275.  
  276.            Added settings in PM2You for priority and keyboard emulation.
  277.  
  278.            Added settings in OS2You for different authorization features.
  279.  
  280. Interim fixes applied to your version 
  281.  
  282.            Better dithering management.
  283.  
  284.            WinTerm speedup and resizable 
  285.  
  286.            Faster compression routine 
  287.  
  288.  
  289. ΓòÉΓòÉΓòÉ 13. Important license information ΓòÉΓòÉΓòÉ
  290.  
  291. Important license information 
  292.  
  293.  It is illegal (or at least unethical) to patch the program in any way.  Any 
  294. reverse engineering (disassembling or monitoring) is not an approved use of the application.
  295.  
  296.  If you register the software you will get a license file and a copy of the 
  297. most recent version of the program.  By registering you will get the following 
  298. benefits: 
  299.  
  300. o You will get a diskette with the most recent version of 
  301.   PM2You/OS2You/M2Zmodem. 
  302.  
  303. o You will get rid of the introduction/registration screen during logon. 
  304.  
  305. o You will be able to run PM2You/OS2You with 38400, 57600 and 115200 bauds. 
  306.  
  307. o You will be treated as registered user for all future release. 
  308.  
  309. o You can sleep at the night without having your conscience haunt you. 
  310.  
  311. If you use the program on a regular basis, or in commercial use, you must 
  312. register for each machine running the PM2You or Os2You program.  The terminal 
  313. programs (except WinTerm) does not require any further registration, and may be 
  314. used in unlimited instances, but an extra registration per each 20th instance 
  315. of LanTerm or LanTerm2 is appreciated.
  316.  
  317.  Note that the file transfer option requires registration.  Neither the built 
  318. in file transfer function or the Sz/Rz commands will work without this option.
  319.  
  320.  Note that there are both non-commercial and commercial licenses available for 
  321. PM2You.  The non-commercial license is for private persons that want to use 
  322. PM2You for their own non-commercial personal use.  The non-commercial license 
  323. does not have the same high support level as the commercial license and limited 
  324. to the OS2You support BBS.
  325.  
  326.  The sourcecode (in Modula-2) of the program is available, on special terms. 
  327. Please contact me if this is of interest.
  328.  
  329.  You are encouraged to spread this program (without registration file) to 
  330. anyone that might be interested.
  331.  
  332.  If you want to register, send Swedish banknotes, bank check (payable in 
  333. Swedish bank) money order, purchase order or pay with VISA, AmEx or MasterCard 
  334. by completing the order form printable from the file ORDER.DOC.
  335.  
  336.  The address is: 
  337.  
  338. Ridax programutveckling
  339. Att: Mikael Wahlgren
  340. Kransen 4E
  341. S-416 72  GOTHENBURG
  342. Sweden
  343. Fax: +46 31 196417
  344. Phone: +46 31 196074
  345. BBS: +46 31 196406
  346. Fidonet: Mikael Wahlgren 2:203/302.5
  347. Compuserve: 100114,3127
  348. Internet: d9mikael@dtek.chalmers.se
  349.  
  350.  Use the following form to register your copy of PM2You/Os2You and M2Zmodem: 
  351.  
  352.                                      INVOICE
  353.  
  354.                                                      Date: ___________
  355.  
  356.        TO:                                           FROM:
  357.  
  358.        Name: ____________________________________    Ridax programutveckling
  359.                                                      Kransen 4E
  360.        Company: _________________________________    S-416 72  Gothenburg
  361.                                                      Sweden
  362.        Address: _________________________________
  363.  
  364.        City, State; _____________________________
  365.  
  366.  
  367.  
  368.        Diskette format                  5.25" disk ____    3.5" disk ____
  369.  
  370.  
  371.        Specification                             Amount Price Sum
  372.        ========================================= ====== ===== ===========
  373.  
  374.        PM2You/OS2You software (first 1-9)        ______  2000  __________
  375.  
  376.        PM2You/OS2You software (following 10-19)  ______  1800  __________
  377.  
  378.        PM2You/OS2You software (following 20-)    ______  1500  __________
  379.  
  380.        PM2You/OS2You software (non commercial)   ______  1000  __________
  381.  
  382.        OS2You software (first 1-9)               ______   700  __________
  383.  
  384.        OS2You software (following 10-19)         ______   600  __________
  385.  
  386.        OS2You software (following 20-)           ______   400  __________
  387.  
  388.        OS2You for Sysops (for BBS use only)      ______   250  __________
  389.  
  390.        OS2You/M2Zmodem file transfer option      ______   300  __________
  391.  
  392.        WinTerm Windows 3.0 terminal program      ______   300  __________
  393.  
  394.        Upgrade from OS2You to to PM2You          ______ -1000  __________
  395.  
  396.        Upgrade from OS2You to non-commerical     ______  -500  __________
  397.        PM2You
  398.  
  399.  
  400.  
  401.                                Total                      SEK  __________
  402.  
  403.        OS2You is included in all PM2You packages.
  404.  
  405.        All prices are in SEK (Swedish crown).  One USD is about 7.20 SEK.
  406.        The price for PM2You/Os2You is about $275.  The prices are valid
  407.        for orders until August 1993.  For orders after that, please
  408.        request the current prices.  For orders from Sweden 25% Moms (VAT)
  409.        should be added to the above prices.
  410.  
  411.        Note that if you order let's say 20 copies of PM2You/OS2You, this
  412.        requires you to pay the full price for the first 1-9 copies, and
  413.        you get a discount only for the following copies.  The "PM2You/
  414.        OS2You non commercial" license is for non-commercial use only
  415.        (for private persons).  Support for non-commerical licenses are
  416.        only available via our BBS and support questions over FAX or phone
  417.        will not be handled.  It is not legal to use the non-commercial
  418.        license for commercial use, even if you don't expect to use the
  419.        support channels available.
  420.  
  421.        If you pay with VISA, AmEx or MasterCard (MasterCards are
  422.        only accepted before August 1993) please fill in the following:
  423.  
  424.  
  425.        Cardholders name: ________________________________________
  426.  
  427.        Cardholders address: _____________________________________
  428.  
  429.        Card number: _____________________________________________
  430.  
  431.        Card validy until: _______________________________________
  432.  
  433.        Signature: _______________________________________________
  434.  
  435.  
  436.  
  437.        Send or FAX a copy of this invoice to:
  438.  
  439.        Ridax programutveckling
  440.        Kransen 4E
  441.        S-416 72  Gothenburg
  442.        Sweden
  443.        Fax: +46 31 196417
  444.        Phone: +46 31 196074
  445.        Compuserve: 100114,3127
  446.        Internet: d9mikael@dtek.chalmers.se
  447.  
  448.        You can also register via CompuServe in forum SWREG and use
  449.        registration ID 767.  You will be billed by CompuServe.
  450.  
  451.