home *** CD-ROM | disk | FTP | other *** search
-
-
- /-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-\
- ! Bell Telephone Info !
- \-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-/
-
-
- ***************************************
-
- BRIDGING HEADS, RESIDENTIAL AND
- BUSINESS MULTILINE DISTRIBUTION BOXES,
- LINE AND TRUNK SPLITTERS, AND
- OTHER BELL SYSTEM WIRE TERMINATIONS.
-
- - HOW TO USE, AND/OR ABUSE THEM -
-
- (INCLUDING A TUTORIAL ON BASIC TELE-
- PHONE EAVESDROPPING TECHNIQUES.)
-
- ***************************************
-
- WRITTEN BY : PHUCKED
- AGENT
- 04
-
- ***************************************
-
- IN THIS ARTICLE, I WILL FIRST
- BESCRIBE THE TERMINATION, WIRING, AND
- TERMINAL HARDWARE MOST COMMONLY USED
- IN THE BELL SYSTEM, AND I WILL INCLUDE
- A SECTION ON METHODS OF USING THEM.
-
- ***************************************
-
- -------------
- LOCAL NETWORK
- -------------
-
- THE LOCAL TELEPHONE NETWORK
- BETWEEN THE CENTRAL OFFICE/EXCHANGE AND
- THE TELEPHONE SUBSCRIBERS CAN BE
- BREIFLY DESCRIBED AS FOLLOWS:
- FROM THE CENTRAL OFFICE (OR
- LOCAL EXCHANGE) OF A CERTAIN PREFIX
- (ES), UNDERGROUND AREA FEEDER TRUNKS
- GO TO EACH AREA THAT HAS THAT PREFIX.
- (USUALLY MORE THAN ONE PREFIX PER AREA)
- AT EVERY FEW STREETS OR TRACT AREAS,
- THE UNDERGROUND CABLES SURFACE. THEY
- THEN GO TO THE SECONDARY TERMINATION,
- (THE AERIAL TELEPHONE FEEDER CABLE)
- (OR BACK UNDERGROUND, DEPENDING ON THE
- AREA) AND THEN TO THE SUBSRIBERS HOUSE
- (OR IN THE CASE OF AN APARTMENT
- BUILDING OR MUTLILINE BUSINESS, TO
- A SPLITTER OR DISTRIBUTION BOX/PANEL).
-
- ****************************************
- NOW THAT WE HAVE THE BASICS, I'LL TRY
- AND GO IN-DEPTH ON THE SUBJECT.
-
- ------------------
- UNDERGROUND CABLES
- ------------------
-
- THESE ARE SOMETIMES INTER-
- OFFICE TRUNKS, BUT USUALLY IN A RESID-
- ENTIAL AREA THEY ARE FEEDER GROUPS THAT
- GO OTO BRIDGING HEADS OR DISTRIBUTION
- CASES. THE CABLES ARE ABOUT 2-3 INCHES
- THICK (VARIES), AND ARE EITHER IN A
- METAL OR PVC-TYPE PIPE (OR SIMILAR).
- RARELY (MAYBE NOT IN SOME REMOTE RURAL
- AREAS) ARE THE CABLES JUST 'ALONE' IN
- THE GROUND. INSTEAD, THEY ARE USUALLY
- IN AN UNDERGROUND CEMENT TUNNEL
- (RESEMBLES A SMALL SEWER OR STORMDRAIN)
- . THE MANHOLES ARE >HEAVY< AND WILL SAY
- 'BELL SYSTEM' ON THEM. THEY CAN BE OPEN
- ED WITH A 1/2 INCH WIDE CROWBAR (HOOK
- SIDE) INSERTED IN THE TOP RECTANGULAR
- HOLE. IF YOU GET IT OPEN, GO INSIDE!!
- THERE ARE LADDER RUNGS TO HELP YOU
- CLIMB DOWN. YOU WILL SEE THE CABLE
- PIPES ON THE WALL, WITH THE BLUE AND
- WHITE STRIPED ONE BEING THE INTER-
- OFFICE TRUNK GRP (AT LEAST IN MY AREA).
- THE OTHERS ARE LOCAL LINES, AND ARE
- USUALLY MARKED OR COLOR CODED. THERE
- IS ALMOST ALWAYS A POSTED COLOR CODE
- CHART ON THE WALL, NOT TO MENTION
- TELCO MANUALS DESCRIBING THE CABLES
- AND TERMINALS, SO I NEED NOT GET INTO
- DETAIL. AGAIN: >IF YOU CAN GET INTO A
- BELL MANHOLE, DO IT!, IT WILL PAY OFF
- <. ALSO, THERE IS USUALLY SOME KIND
- OF TEST EQUIPMENT, AND OFTEN BELL
- TEST SETS ARE LEFT IN THERE.
- SO GET YOUR CROWBARS!
-
- ****************************************
- --------------
- BRIDGING HEADS - (WE MS2'S)
- --------------
-
- THE INNOCENT-LOOKING GRAYISH-
- GREEN BOXES.
- WHEN IN GROUPS OF TWO OR THREE, THEY
- ARE FOR SECONDAY/TERTIARY TERMINATION
- AND ACCESS POINTS (BRIDGED ACCESS).
- THESE ARE THE WESTERN ELECTRIC SAI
- 55 OR 22/E TERMINAL CASES. THEY HOLD
- ON THE ORDER OF 900-1200 CABLE PAIRS.
- THIS IS USUALLY THE SECOND TERM. POSI
- TION ON THE LOCAL LOOP (AFTER THE MTF
- FRAME AT THE CO/ OR THE UNDERGROUND
- 'FTP' POSITION).
- THESE CAN BE EITHER
- TRUNK BRIDGES OR BRIDGING FOR RESIDEN
- CES. THE AREA FEEDER BRIDGING HEADS
- ARE USUALLY LARGER, AND THEY HAVE THE
- 'WESTERN ELECTRIC' LOGO AT THE BOTTOM,
- WHEREAS THE NORMAL BRIDGING HEADS
- (WHICH MAY BE DIFFERENT IN SOME AREAS-
- DEPENDING ON THE COMPANY YOU ARE
- SERVED BY. GTE B.H'S LOOK SLIGHTLY
- DIFFERENT. ALSO, DO NOT BE FOOLED
- BY SPRINKLER BOXES!)
- CAN BE FOUND IN JUST ABOUT EVERY CITY.
- TO OPEN A BRIDGING HEAD:
- IF IT IS LOCKED (AND YOU'RE FEELING
- DESTRUCTIVE), PUT A HAMMER OR CROWBAR
- (THE SAME ONE YOU USED ON THE MANHOLE
- ) IN THE SLOT ABOVE THE TOP HINGE OF
- THE RIGHT DOOR. PULL HARD, AND THE
- DORR WILL RIP OFF. VERY EFFECTIVE!
- IF IT ISN'T LOCKED (AS USUAL),
- TAKE A 7/16 INCH HEX SOCKET AND
- WITH IT, TURN THE BOLT ABOUT 1/8 OF A
- TURN TO THE LEFT (YOU SHOULD HEAR
- A SPRING RELEASE INSIDE). HOLDING THE
- BOLT, TURN THE HANDLE ALL THE WAY TO
- THE RIGHT AND PULL OUT.
- NOW INSIDE, FIRST CHECK FOR
- A TEST-SET (WHICH ARE OFTEN LEFT BY
- BELL EMPLOYEES). THERE SHOULD BE A
- PANEL OF CABLE PAIRS + SCREW TERMINALS
- (TYPE 45/47IB REGULAR BINDERS) . PUSH
- THE PANEL BACK ABOUT AN INCH OR SO,
- AND ROTATE THE TOP LATCH (ROUND WITH
- A FLAT SECTION) DOWNWARD. RELEASE THE
- PANEL AND IT WILL FALL ALL THE WAY
- FORWARD. THERE IS USUALLY A LARGE AMO-
- UNT OF WIRE AND EXTRA TERMINALS.
- THE TEST-SETS ARE OFTEN HIDDEN HERE,
- SO DONT OVERLOOK IT (400 FOOT ROLLS OF
- #22 SOLID WIRE ARE OFTEN NEAR THE TOP
- IN THE BACK OF THE BOX. 'BORROW THEM')
- . ON THE RIGHT DOOR IS A METAL BOX OF
- INSULATORS, BINDERS, CLIPS, ETC. TAKE
- A FEW (COMPLIMENTS OF BELL...). ON EACH
- DOOR IS A USEFUL ROUND METAL DEVICE.
- (SAYS 'INSERT GENTLY' OR 'CLAMP GENTLY
- - DO NOT OVERTIGHTEN' ETC..) ON THE
- FRONT OF THE DISC, YOU SHOULD FIND TWO
- TERMINALS. THESE ARE FOR YOUR TEST SET.
- (IF YOU DONT HAVE ONE, DONT DEPAIR -
- I'LL SHOW YOU WAYS TO MAKE BASIC TEST
- SETS LATER IN THIS ARTICLE).
- HOOKING THE RING (-) WIRE TO THE
- 'R' TERMINAL; AND THE TIP (+) WIRE
- TO THE OTHER. (BY THE WAY, AN EASY WAY
- TO DETERMINE THE CORRECT POLARITY IS
- WITH A 1.5V LED. TAP IT TO THE TERM.
- PAIR, IF I DOESNT LIGHT, SWITCH THE
- POLES UNTIL IT DOES. WHEN IT LIGHTS,
- FIND THE LONGER OF THE TWO LED POLES.
- THIS ONE WILL BE ON THE TIP WIRE (+))
- BEHIND THE DISC IS A COILED UP CORD.
- THIS SHOULD HAVE A SPECIALIZED CONNECT-
- OR. ITS VERY USEFUL, BECAUSE YOU
- DONT HAVE TO KEEP CONNECTING AND
- DISCONNECTING THE FONE (TEST SET)
- ITSELF, AND THE CLIP IS DESIGNED TO AID
- IN LOCATING THE PAIR AND ASSURING THE
- CORRECT POLARITY.
- ON THE TERMINAL BOARD, THERE
- SHOULD BE ABOUT 20 PAIRS (RED/WHITE)
- PER ROW PER SIDE.
- HOOK THE CLIP TO ANY TERMINAL PAIR
- , AND YOU'RE SET! DIAL OUT IF YOU WANT,
- OR JUST LISTEN (IF SOMEONE'S ON THE
- LINE). LATER, I'LL SHOW YOU A WAY TO
- SET UP A TRUE 'TAP' THAT YOU CAN SET
- UP, AND WILL LET THE PERSON DIAL OUT
- ON HIS LINE AND RECEIVE CALLS AS
- NORMAL, AND YOU CAN LISTEN IN THE
- WHOLE TIME. MORE ABOUT THIS LATER...
- ON MAJOR PREFIX-AREA BRIDGING
- HEADS ('SAI' FOR AREA C.O. FEEDER CABLE
- ) YOU CAN SEE TEMPORARY 'LOCAL LOOPS',
- WHICH ARE TWO CABLE PAIRS (CABLE
- PAIR = RING+TIP, A FONE LINE) THAT
- ARE DIRECTLY CONNECTED TO EACH OTHER
- ON THE TERMINAL BOARD. THESE 'CHEAP
- LOOPS' AS THEY ARE CALLED, DO NOT
- WORK NEARLY AS WELL AS THE EXISTING
- ONES SET UP IN THE SWITCHING HARDWARE
- AT THE EXCHANGE OFFICE. (TRY SCANNING
- YOUR PREFIXES' 00XX OR 99XX #'S.
- THE TONE SIDES WILL ANNOUNCE THEMSELVES
- WITH THE 1000 HZ LOOP TONE, AND THE
- HANG SIDE WILL GIVE NO RESPONSE. THE
- FIRST PERSON SHOULD DIAL THE 'HANG'
- SIDE, AND THE OTHER PERSON DIAL THE,
- TONE SIDE, AND THE TONE SHOULD STOP
- IF YOU HAVE GOT THE RIGHT LOOP).
- THE LOOPS ARE USED IN FRAME TERMINATI
- ON AND IN SONIC/600 OHM TERM. TESTING
- AND LINE/CABLE/FEEDER LOCATION.
- IF YOU WANT TO FIND THE NUMBER
- OF THE LINE THAT YOU'RE ON, YOU CAN
- EITHER TRY TO DECIPHER THE 'BRIDGING
- LOG' (OR WHATEVER), WHICH IS ON THE
- LEFT DOOR. IF THAT DOESNT WORK, YOU
- CAN USE THE FOLLWING:
-
- ---
- ANI # (AUTOMATIC NUMBER INDENTICATION)
- ---
- THIS IS A TELCO TEST NUMBER
- THAT REPORTS TO YOU THE NUMBER THAT
- YOURE CALLING FROM (IT'S THE SAME,
- CHOPPY 'BELL BITCH' VOICE THAT YOU
- GET WHEN YOU REACH A DISCONNECTED #)
- (PIP OR ONE OF THE 11X SERIES ANNOUNCE
- MENT FRAME MACHINES.)
-
- FOR THE 213 NPA - DIAL 1223
- 213 NPA - (GTE AREAS) DIAL 114
- 408 NPA - DIAL 760
- 914 NPA - DIAL 990
-
- THESE ARE EXTREMELY USEFUL WHEN MESSING
- WITH ANY KIND OF LINE TERMINALS,
- FEEDER BOXES, ETC.
-
- ----------
-
- WHEN FINISHED, BE SURE TO CUT
- OFF THE CONNECTOR AND TAKE IT WITH YOU
- (THEY ARE VERY HANDY), AND CLOSE/LATCH
- THE BOX TO AVOID SUSPICION.
-
- ***************************************
-
- ------
- "CANS" - AERIAL-MOUNTED (TELEPHONE POLE
- ------ TERMINAL) BRANCH FEEDER CABLE
- SPLITTER.
-
- BASICALLY, TWO TYPES:
-
- 1> MS3A SERVICE AREA INTERFACE.
- (LARGE, RECTANGULAR SILVER BOX AT
- THE END OF EACH STREET.)
-
- 2> SERIES 600 LOADING COIL, INCLUDES
- THE MSX AERIAL DROP SPLITTER.
- (BLACK, ROUND OR RECTANGULAR THING
- AT EVERY TELEPHONE POLE.)
-
- --------
-
- TYPE 1 - THIS IS THE CASE THAT TAKES
- THE UNDERGROUND CABLE FROM THE BRIDGER
- AND RUNS IT TO THE AERIAL BRANCH FEEDER
- CABLE (THE LOWEST, LARGEST WIRE ON THE
- TELEPHONE POLE). THE BOX IS ALWAYS ON
- THE POLE NEAREST THE BRIGING HEAD,
- WHERE THE LINE COMES UP. LOOK FOR THE
- 'CALL BEFORE YOU DIG - UNDERGROUND
- CABLE' STICKERS..
- THE CASE BOX IS HINGED, SO IF
- YOU WANT TO CLIMB THE POLE, YOU CAN
- OPEN IT WITH NO PROBLEMS. THESE USUALLY
- HAVE 2 ROWS OF TERMINAL SETS.
- (TOTAL APPROX. 200-600 PAIRS, DEPENDING
- ON THE AREA.) THESE ARE ALL THE CABLE
- PAIRS FOR YOUR STREET.
- . (ITS SIMILAR TO A MINIATURE BRIDGING
- HEAD). USE/ABUSE IT IN THE SAME MANNER
- AS WE DID BEFORE. (NOTE: ALL THE ACTIVE
- LINES CARRY FROM 15 TO 48 VDC, AND
- EVEN 90VAC (WHEN RINGING), SO BE
- CAREFUL - IT'S NOT GOING TO HURT YOU,
- BUT IT CAN SURPRISE YOU (AND IF
- YOU'RE HANGING BY ONE HAND FROM A TEL.
- POLE, IT >CAN< BE HARMFUL!))
- OH, BY THE WAY, IF YOU USE
- ANI ON EVERY PAIR AND YOU FIND ONE
- THAT ISNT IN USE ON YOUR STREET, YOU
- CAN HOOK IT UP FOR YOURSELF (ALMOST).
- ALSO, YOU HAVE TO BE ABLE TO IMPER-
- SONATE A TELCO TECHNICIAN AND REPORT
- THE NUMBER AS 'NEW ACTIVE' (GIVING
- A FAKE NAME AND FAKE REPORT, ETC)
- I DONT RECOMMEND THIS AND IT PROBABLY
- WONT (ALMOST POSITIVELY WONT) WORK,
- BUT THIS IS BASICALLY WHAT TELCO
- LINEMEN DO).*
-
-
- * THE USE OF THE 'TEST BOARD'
- (A 7D# FOR LINEMEN TESTS, OFTEN FOUND
- NXX-0003 OR NXX-0004) IS BEYOND THE
- SCOPE OF THIS ARTICLE, BUT WILL BE
- COVERED IN A FUTURE ARTICLE.
-
- ----
-
- TYPE 2 - THIS IS THE SPLITTER BOX FOR
- THE AERIAL DROP WIRES FOR THE GROUP OF
- HOUSES AROUND THE POLE.
- (USUALLY 4 OR 5 HOUSES). USE IT
- LIKE I MENTIONED BEFORE. THE TERMINALS
- (20 OR SO) WILL BE IN 2 HORIZONTAL
- ROWS OF SETS. THE EXTRA WIRES THAT ARE
- JUST 'HANGING THERE' ARE PROVISIONS
- FOR EXTRA LINES TO RESIDENCES (1 EXTRA
- LINE PER HOUSE, THATS WHY THE INSANE
- CHARGE FOR LINE #3). IF ITS THE BOX FOR
- YOUR HOUSE ALSO, HAVE FUN AND SWAP
- LINES WITH YOUR NEIGHBOR! 'PIGGYBACK'
- THEM OR USE A CHEESEBOX FOR A LOOP-ARO
- UND, ETC.
- AGAIN, I DONT RECOMMEND THIS, AND ITS
- DIFFICULT TO DO IT CORRECTLY. (ALTHOUGH
- USEFUL)
-
- ***************************************
- ---------------------------------------
-
-
- DOWNLOADED FROM P-80 SYSTEMS.
-
-