  1.                              TECHNICAL BULLETIN
  2.                                Bulletin 1-274
  3.                              September 10, 1990
  4.  
  5.            Patches and Enhancements Relating to IBM PS/2 Hardware
  6.  
  7. Several NetWare patches and enhancements have been released on NetWire
  8. relating to IBM PS/2 hardware.  The following list identifies the problem
  9. area, describes the patch and/or enhancement, and provides, in parentheses,
  10. the filename on NetWire to download.
  11.  
  12. PS/2 SCSI driver.  IBMSCSI.OBJ (dated 7-31-90) supports both caching and non
  13.       caching PS/2 SCSI controllers.  This driver is for Advanced and SFT
  14.       NetWare 286 v2.15 Rev. C.  (PS2286.ZIP)
  15.  
  16. PS/2 SCSI driver for ELS II.  This archive file includes several operating
  17.       system and utility files that have the PS/2 SCSI driver linked in. 
  18.       IBMSCSI.OBJ v1.02 (dated 7-31-90) supports both caching and non-caching
  19.       PS/2 SCSI controllers.  This driver is for ELS NetWare Level II v2.15
  20.       Rev. C.  (ESCI.ZIP)
  21.  
  22. 32-bit memory board and cold boot loader.  The IBM PS/2 80386 memory board
  23.       software destroys the NetWare cold boot loader stored at Track 0 on a
  24.       file server.  Previous to this patch, NetWare had to be booted from
  25.       diskette when using the memory board on a file server (see Technical
  26.       Bulletin 1-263). This patch allows a netware operating system to be 
  27.       cold-booted when the IBM memory board is installed in the server. This 
  28.       patch applies to Advanced and SFT NetWare 286 v2.15 Rev C. (IBMMEM.ZIP)
  29.  
  30.       Note:    This patch is implemented using the patch applicator ZAPOBJ. 
  31.                However, this patch cannot be used in conjunction with other
  32.                patches applied with ZAPOBJ. 
  33.  
  34. UPS monitoring on Model 70.  This patch modifies the NetWare operating system
  35.       to allow IBM PS/2 Model 70 computers with Type II keyboard controllers 
  36.       to work properly with a UPS.  This patch applies to Dedicated versions
  37.       of Advanced, SFT, TTS, and ELS Level II NetWare v2.15 Rev C. 
  38.       (UPSM70.ZIP)
  39.  
  40.       Note:    This patch cannot be implemented on the same system as the 
  41.                80386 PS/2 memory board patch.  (IBMMEM.ZIP)
  42.  
  43. Model 30-286 driver.  This file includes fixes to the problem of running
  44.       NetWare on PS/2 Model 30-286 machines on Seagate drives.  These drives
  45.       operate somewhat differently from other drives shipped with the 
  46.       machine.  The result of these differences is the error message 
  47.       Abend: Unable to reset PS/2 internal disk controller.  This message, 
  48.       or a similar disk-access message, is displayed whenever the disk is 
  49.       accessed by the operating system or utilities.  These patches apply to 
  50.       the PS/2 Model 30-286 driver for ELS I v2.12, ELS II v2.15, and 
  51.       Advanced and SFT NetWare 286 v2.15.  (M30PAT.ZIP)
  52.  
  53. Model 70 A21 anomaly.  Some problems have arisen running NetWare on a Model 
  54.       70 A21 with the 121 Mb ESDI drive.  Intermittent errors and server 
  55.       "hangs" have been experienced primarily with ARCnet NICs, but sometimes
  56.       with other topologies.  The problems stem from a controller-setting 
  57.       routine that is not given enough time to perform its function.  This 
  58.       problem can be avoided by using the Reference diskette to set the 
  59.       Preempt parameter to "Disabled."