  1.                        TECHNICAL BULLETIN
  2.                          Bulletin #1-269
  3.  
  4. Date:  April 27, 1990
  5.  
  6.               Error in 3Com Installation Supplement
  7.  
  8. The addendum to the NetWare Installation Supplement for 3Com
  9. Etherlink and Etherlink Plus (revision 1.00, P/N 101-385-001)
  10. contains erroneous information.  Specifically, the configuration
  11. option table (Figure 2) is incorrect for every option.  The correct
  12. configuration option information for DOS is listed below. 
  13.  
  14.      3Com 3C503 EtherLink II 
  15.  
  16.      0.   I/O = 300h, INT = 3, DMA = 1, BNC 
  17.      1.   I/O = 310h, INT = 2, DMA = 3, BNC 
  18.      2.   I/O = 330h, INT = 4, RAM = C8000, BNC 
  19.      3.   I/O = 350h, INT = 5, RAM = CC000, BNC 
  20.      4.   I/O = 250h, INT = 3, RAM = D8000, BNC 
  21.      5.   I/O = 280h, INT = 2, RAM = DC000, BNC 
  22.      6.   I/O = 2A0h, INT = 4, DMA = 1, BNC 
  23.      7.   I/O = 2E0h, INT = 5, DMA = 3, BNC 
  24.      8.   I/O = 300h, INT = 3, RAM = C8000, BNC 
  25.      9.   I/O = 310h, INT = 2, RAM = CC000, BNC 
  26.      10.  I/O = 330h, INT = 4, RAM = D8000, BNC 
  27.      11.  I/O = 350h, INT = 5, RAM = DC000, BNC 
  28.      12.  I/O = 250h, INT = 3, DMA = 1, BNC 
  29.      13.  I/O = 280h, INT = 2, DMA = 3, BNC 
  30.      14.  I/O = 2A0h, INT = 4, RAM = C8000, BNC 
  31.      15.  I/O = 2E0h, INT = 5, RAM = CC000, BNC 
  32.      16.  I/O = 300h, INT = 3, DMA = 1, DIX 
  33.      17.  I/O = 310h, INT = 2, DMA = 3, DIX 
  34.      18.  I/O = 330h, INT = 4, RAM = C8000, DIX 
  35.      19.  I/O = 350h, INT = 5, RAM = CC000, DIX 
  36.      20.  I/O = 250h, INT = 3, RAM = D8000, DIX 
  37.      21.  I/O = 280h, INT = 2, RAM = DC000, DIX 
  38.      22.  I/O = 2A0h, INT = 4, DMA = 1, DIX 
  39.      23.  I/O = 2E0h, INT = 5, DMA = 3, DIX 
  40.      24.  I/O = 300h, INT = 3, RAM = C8000, DIX 
  41.      25.  I/O = 310h, INT = 2, RAM = CC000, DIX 
  42.      26.  I/O = 330h, INT = 4, RAM = D8000, DIX 
  43.      27.  I/O = 350h, INT = 5, RAM = DC000, DIX 
  44.      28.  I/O = 250h, INT = 3, DMA = 1, DIX 
  45.      29.  I/O = 280h, INT = 2, DMA = 3, DIX 
  46.      30.  I/O = 2A0h, INT = 4, RAM = C8000, DIX 
  47.      31.  I/O = 2E0h, INT = 5, RAM = CC000, DIX 
  48.  
  49. Although the supplement is incorrect, the correct options are
  50. displayed when choosing the configuration in SHGEN under DOS. 
  51. However, when the Multiple Link Interface Drivers (MLID) are
  52. installed as device drivers under OS/2, the configuration options
  53. are not displayed.  The default configuration for OS/2 is:
  54.  
  55.      I/O = 300h, INT = 3, RAM = C8000, BNC 
  56.  
  57. Note that the Base Memory Address may not be set to "Disabled" when
  58. running the 3C503 board with the NetWare Requester for OS/2.  See
  59. the NetWare Requester for OS/2 Supplement for additional
  60. information on reconfiguring the NetWare Requester.