- Good day all netters
-
- We'd _really_ appreciate any help.
-
- We are experiencing a problem with our VAXstation 3100 Model 76
- workstations running DECwindows Motif V1.0 and VMS V5.5-1. Sometimes,
- when we resize a window, the window dissappears and the underlying
- process dies. We have managed to recreate the problem ( virtually
- without fail ) by inverting a DECterm window, ie resizing the window
- to a negative size by moving the bottom horizontal edge past the top of
- the top horizontal edge. This impossible resizing does not work ( to be
- expected ), but the DECterm process dies with the exact same message
- that we get _sometimes_ when the window dissapppears after doing only a
- normal valid resizing of the window. The DECTERM_ERROR.LOG file contains
- the following message:
-
- DECterm version V3.0 error occurred on Tue Nov 3 11:04:42 1992
-
- Text of error message:
-
- %XLIB-ERROREVENT
-
- Mapped Images...
-
- BASE START END LENGTH IMAGE NAME
- ---- ----- --- ------ ----------
- 200 200 11fff 11dff DECW$TERMINAL
- 253c00 253c00 2835ff 2f9ff DECW$TERMINALSHR
- 1db400 1db400 24b3ff 6ffff DECW$DXMLIBSHR
- 24b400 24b400 253bff 87ff LBRSHR
- d7000 d7000 1a59ff ce9ff DECW$XMLIBSHR
- 1ada00 1ada00 1db3ff 2d9ff DECW$XTSHR
- 1a5a00 1a5a00 1ad9ff 7fff DECW$DWTLIBSHR
- 7e000 7e000 d29ff 549ff DECW$XLIBSHR
- d2a00 d2a00 d6fff 45ff DECW$TRANSPORT_COMMON
- 3c400 3c400 53fff 17bff VAXCRTL
- 54000 54000 7dfff 29fff MTHRTL
- 3ba00 3ba00 3c3ff 9ff PTD$SERVICES_SHR
- 1c400 1c400 223ff 5fff SECURESHR
- 22400 22400 3b9ff 195ff LIBRTL
- 12000 12000 1c3ff a3ff SECURESHRP
- 2c4600 2c4600 2c63ff 1dff DECW$TRANSPORT_LOCAL
- 371000 371000 3717ff 7ff DECW$TERMINALMSG
- 371800 371800 3725ff dff VAXCMSG
- 372600 372600 372bff 5ff DECW$XLIBMSG
- 372c00 372c00 3739ff dff DECW$TRANSPORTMSG
-
- IMAGE+offset of call
- --------------------
- DECW$XLIBSHR+26bb4 2bb290, 7ff7d991
- DECW$XLIBSHR+26c39 2bb290, 7ff7d9dc
- DECW$XLIBSHR+2847b 2bb290, 7ff7da98
- DECW$XLIBSHR+278f3 2bb290, 7ff7db04, 0, 1
- DECW$XLIBSHR+16bc8 2bb290, 258051, 0
- DECW$TERMINALSHR+206d5 30d020
- DECW$TERMINALSHR+1b5db 30d020
- DECW$XTSHR+2032b 30d020, 0, 7d, 7c, ffe2, 0
- DECW$XMLIBSHR+a3ad9 30d020, 0, 7d, 7c, ffe2, 0
- DECW$XMLIBSHR+84ce5 2c3b18
- DECW$XMLIBSHR+858e8 2c3b18
- DECW$XMLIBSHR+7325b 2c3b18
- DECW$XTSHR+20226 2c3b18, 7c, 5f, 0
- DECW$XMLIBSHR+9e523 2e41d0
- DECW$XMLIBSHR+3477a 2e41d0, 2e5c08, 7ff7e34c, 7ff7def3
- DECW$XTSHR+186fe 7ff7e34c, 2e41d0, a0000, 2bc944
- DECW$XTSHR+18d3b 7ff7e34c
- DECW$XTSHR+18ef3 7ff7e34c
- DECW$XTSHR+19ea3 2ba008, 7
- DECW$TERMINAL+81fc 1, 284e40, 284e10
- 802630ce 7ffe5ebc, 0, 3000b0, 580044, a80000, 35303230, 102,
- ffffffff, ffffffff
-
- End of DECTERM_ERROR.LOG message.
-
- The DECW$TERMINAL and DECW$TERMINALSHR images were linked on 17-JUL-1991,
- all other DECW$ images were linked on 01-JUL-1991. The images are all
- version DW V1.0-910630 (from the image file).
-
- Hardware version info: VS3100-M76 VS43A-BD
-
- sho ver> KA43A V1.20C-185-V1.6-26A
- PST: 185
- CON: 20c
- VMB: V1.6
- ROM: 26A
- when booting sys .... KA43A V1.2
- KA43A firmware = 2.3-134E8
- 2.3-135E8
-
- If this is a known bug, please let me know. Also if there are patches
- available or any workarounds.
-
- Thanks
-
- J.A.Nel