- dkw@wolferts.ka.sub.org (Klaus Wolferts) writes:
- : I have a modem (Digicom Scout Plus) with all the trimmings (V.32bis, V.42,
- : V.42bis, ...) too and I still get some errors during Zmodem downloads.
- :
- : Even on pure local connections I regularly get CRC errors, timeouts
- : or bad subpacket errors every other second so that the data rate on
- : downloads seldom climbs over 900 cps at 14400 EC, often 700..800 cps.
- : The line dont seem noisy, signal strength shows -27...-24 dBm and
- : signal quality shows mostly 7 or 6 on a scale of 0...7 (nice feature
- : on the Scout Plus).
- :
- : That means most file transfers need about twice the time to download,
- : a factor of 3 is no great improvement over my earlier 2400 (no EC) modem
- : when I hoped for a 6 fold improvement.
- :
- : Or can that be a weakness of my datacom software (Telix 3.12)?
- :
- : Or the missing 16550? (DTE rate 57600 or 38400, 12 MHz Compaq 286).
- :
- : Any ideas, what could be wrong?
-
- I use an 8250 UART with a Scout+ just to see how it works. I dont get
- many errors at all, but can use only 38,400 baud as the highest DTE
- speed. Most important, though, is that all the toggles in Qmodem 4.31
- are set correctly. 'DTE when writing' must be set to OFF, otherwise I
- experience overrun errors whenever data gets written to disk. 'Hi-speed
- transmit' must be set ON, etc. In general I find a setup with a 8250
- requires more fine-tuning, in particular at speeds of 38,400 or
- 57,600 baud DTE. If you still get errors after checking your settings,
- I recommend to install a 16550AFN UART on your serial port.
-
- With a 16550AFN 16 byte buffer and a 57,600 baud DTE rate I can set the
- toggles in the wrong positions and still dont get errors. Its more fault
- tolerant, including operator error.
-
-
- --
- _________________________________________________________________________
- Wolfgang Henke wolfgang@henke.sf-bay.org wolfgang@netcom.com
-
-