home *** CD-ROM | disk | FTP | other *** search
- Newsgroups: comp.dcom.sys.cisco
- Path: sparky!uunet!boulder!recnews
- From: Omar Barazanji <barzanji@cisco.com>
- Subject: [bjripp@watson.ibm.com: token-ring reset failed]
- Message-ID: <9209021805.AA19437@last-call.cisco.com>
- Sender: news@colorado.edu
- Date: 2 Sep 92 11:05:02 -0700
- Lines: 64
-
-
-
- Dear Bill,
-
- With regards to the TR-3-RESETFAIL error message, we have identified
- and fixed this bug approximately three months ago. I am very sorry
- that you have not been notified acordingly. In the future, please
- use our escalation procedure should one of our engineers fails to
- respond to your reported trouble ticket in a timely manner. I have
- left you my direct number on your voice mail. Please call me as soon
- as possible so that we can resolve this issue immediately.
-
- If I can be of any further service, please do not hesitate to call
- me.
-
- Yours Sincerely
-
- Omar Barzanji
- Customer Engineering
-
-
-
- >The problem (see attached) may be related to the level of
- >Token-ring microcode you are running. I have a case opened
- >with cisco dating back to February, case number 15766. They
- >have not come up with a resolution yet. When I tried to
- >upgrade from SBEMON 2.0(112) to 3.0(1) I had trouble on
- >the 4Mb rings that were highly utilized to the point where
- >the cisco would crash on a bus error. Prior to the crash I
- >received reset failed messages for the interface. I am
- >currently running my 16Mb rings on the 3.0 code and my
- >4Mb rings on the 2.0 code. I just hope the problem doesnt
- >surface on the 16Mb ring when my users are able to push
- >it to 90+ %.
-
- >Bill Rippon Phone: 914-784-7479
- >IBM Watson Research Center Email: bjripp@watson.ibm.com
-
- ------- Forwarded Message
-
- Date: Mon, 31 Aug 92 20:11:08 +0700
- From: Peter Hakanson <peter@cyklop.volvo.se>
- To: cisco@spot.colorado.edu
- Subject: TR-3-RESETFAIL: Unit 0, reset failed, error code 00007F32.
-
- since you guys out there so rapidly answers my questions,
- we have an acute problem with an AGS+ and t/r 16 Mbit board.
- (AGS+ 8.3(3), CSC-R16 in 4Mbit mode, 5 4E4T boards in box)
-
- After power on we get :
- %TR-3-RESETFAIL: Unit 0, reset failed, error code 00007F32.
- - -Traceback= 97F98 97D0E 970B6 96FD2 9C5FC 12766 37F8 1D1E
-
- and the manual states : 'if message recurs, contacr Cisco Systems.'
-
- I did this, now i've waited the hour they said and noone has called me yet.
-
- Does anyone out there knows what to do ?
- - --
- Peter Hakanson VolvoData Dep 2230 phone +46 31 66 74 27
-
- ------- End of Forwarded Message
-
-
-