home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #19 / NN_1992_19.iso / spool / comp / dcom / modems / 12944 < prev    next >
Encoding:
Text File  |  1992-09-03  |  3.9 KB  |  190 lines

  1. Newsgroups: comp.dcom.modems
  2. Path: sparky!uunet!decwrl!csus.edu!netcom.com!wolfgang
  3. From: wolfgang@netcom.com (Wolfgang Henke)
  4. Subject: Re: Digicom Scout Plus Bug, Feature or Operator Error??
  5. Message-ID: <zbmnq7.wolfgang@netcom.com>
  6. Date: Fri, 04 Sep 92 07:01:35 GMT
  7. Organization: Netcom
  8. References: <1992Sep3.172920.1670@aw2.fsl.ca.boeing.com>
  9. X-Newsreader: Tin 1.1 PL4
  10. Lines: 178
  11.  
  12. vds7789@aw2.fsl.ca.boeing.com (Vincent D. Skahan) writes:
  13. : >Note also that the documentation doesn't necessarily reflect what
  14. : >the modem will actually do and there was no addenda with mine.
  15. : They have a lot of nerve calling it a "users' manual".  It's neither
  16. : a manual nor for users.  Worst piece of useless junk I ever read.
  17.  
  18.  
  19. The Scout+ has online help. Thats what I use. Turn it around, look at
  20. the bottom label. The top command listed is ATI7. Lets try it:
  21.  
  22. ati7
  23. AT COMMAND ECHOING:
  24.  E0: Disable
  25.  E1: Enable
  26.  
  27. HOOK ON/OFF CONTROL:
  28.  H0: On  hook
  29.  H1: Off hook
  30.  
  31. MISCELLANEOUS COMMANDS:
  32.  I0: Firmware version
  33.  I1: Firmware date code
  34.  I2: Firmware checksum
  35.  I3: OK
  36.  I4: CPU RAM content
  37.  I5: Power-on test results
  38.  I6: Last disconnect reason
  39.  I7: AT commands summary
  40.  I8: EE-PROM content
  41.  
  42. BREAK DETECTION IN MNP/V42 MODE:
  43.  K0: Disable
  44.  K1: Enable
  45. SPEAKER CONTROL:
  46.  M0: Always OFF
  47.  M1: On for handshake
  48.  M2: Always ON
  49.  
  50. MODEM MESSAGE ON/OFF OPTION:
  51.  Q0: On
  52.  Q1: Off
  53.  
  54. DISPLAY SIGNAL QUALITY ON COMMAND MODE:
  55.  SQ
  56.  
  57. MODEM MESSAGE LONG/SHORT FORM OPTION:
  58.  V0: Short
  59.  V1: Long
  60.  
  61. CONNECTION MESSAGE AND DT/BT DETECTION OPTION:
  62.  X0: DT/no   BT/no    CONNECT
  63.  X1: DT/no   BT/no    CONNECT xxxx
  64.  X2: DT/yes  BT/no    CONNECT xxxx
  65.  X3: DT/no   BT/yes   CONNECT xxxx
  66.  X4: DT/yes  BT/yes   CONNECT xxxx
  67.  X5: DT/yes  BT/yes   CONNECT
  68.  
  69. DIALING MODE:
  70.  T: Tone
  71.  P: Pulse
  72.  
  73. DSR SIGNAL OPTION:
  74.  &B0: Always on
  75.  &B1: Follows DTR
  76.  &B2: Normal RS232
  77.  
  78. DCD SIGNAL OPTION:
  79.  &C0: Always on
  80.  &C1: Normal RS232
  81.  &C2: Wink 1sec after disconnection
  82.  
  83. MODEM REACTION ON LOSS OF DTR SIGNAL:
  84.  &D0: None
  85.  &D1: Enter command mode
  86.  &D2: Disconnect
  87.  &D3: Reload pre-stored options
  88.  
  89. LOAD FACTORY DEFAULT:
  90.  &F
  91.  
  92. CTS SIGNAL OPTION:
  93.  &R0: Follows RTS
  94.  &R1: Normal RS232
  95.  &R2: Always on
  96.  
  97. LIST STORED PHONE NUMBERS:
  98.  &S
  99.  
  100. TEST MODE COMMANDS:
  101.  &T0: Stop test
  102.  &T1: ALB
  103.  &T3: LDLB
  104.  &T4: Enable  response to RDLB
  105.  &T5: Disable response to RDLB
  106.  &T6: RDLB
  107.  &T7: RDLB selftest
  108.  &T8: ALB  selftest
  109.  
  110. PERMANENTLY STORE OPTIONS:
  111.  &W
  112.  
  113. STORE PHONE NUMBERS TO LOCATION n:
  114.  &Zn:
  115.  
  116. MNP/V42 OPTIONS:
  117.  *E0: Plain mode/No error correction
  118.  *E1: MNP5
  119.  *E2: Relibale MNP5
  120.  *E3: MNP4
  121.  *E4: Reliable MNP4
  122.  *E5: V42 w/ det phase
  123.  *E6: Reliable V42 w/ det phase
  124.  *E7: V42 w/o det phase
  125.  *E8: Reliable V42 w/o det phase
  126.  *E9: V42bis w/ det phase
  127.  *E10: Reliable V42bis w/ det phase
  128.  
  129. FLOW CONTROL OPTIONS:
  130.  *F0: None
  131.  *F1: XON/XOFF pass through mode
  132.  *F2: XON/XOFF
  133.  *F3: RTS/CTS
  134.  
  135. ADAPTIVE HANDSHAKE OPTION:
  136.  *G0: Disable
  137.  *G1: Enable
  138.  
  139. RESULT CODE OPTION:
  140.  *M0: Display DTE speed on result code
  141.  *M1: Display DCE speed and "EC" on result code
  142.  *M2: Display DCE speed and "EC/xxxx" on result code
  143.  
  144. DISPLAY CURRENT OPERATION PARAMETERS:
  145.  *O
  146.  
  147. USER ABORT ON HANDSHAKING
  148.  *P0: Enable
  149.  *P1: Disable
  150.  
  151. MODEM ACTION ON BAD SIGNAL QUALITY:
  152.  *Q0: None
  153.  *Q1: Retrain
  154.  *Q2: Adaptive retrain
  155.  *Q3: Disconnect
  156.  
  157. SPEED CONVERSION OPTION:
  158.  *S0: Disable
  159.  *S1: Enable
  160.  
  161. TRELLIS OPTION OF 9600 BPS:
  162.  *T0: Off
  163.  *T1: On
  164.  
  165. S-REGISTERS:
  166. S0:  Number of rings until answer
  167. S1:  Number of rings received
  168. S2:  ESC
  169. S3:  CR
  170. S4:  LF
  171. S5:  BS
  172. S6:  DT wait period
  173. S7:  Handshake abort timer
  174. S8:  Dialing pause time of "," 
  175. S9:  Delayed DCD response of energy recovery
  176. S10: Delayed disconnection response on loss of energy
  177. S12: ESC code guard time
  178. S15: MNP/V42 negotiation abort character
  179. S18: Test mode duration
  180. S25: Delayed response of DTR on to off change
  181. S26: Delayed response of RTS off to on change
  182.  
  183. OK
  184.  
  185. -- 
  186.    _________________________________________________________________________
  187.    Wolfgang Henke        wolfgang@henke.sf-bay.org       wolfgang@netcom.com
  188.  
  189.