home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #18 / NN_1992_18.iso / spool / comp / sys / sun / admin / 5711 < prev    next >
Encoding:
Text File  |  1992-08-20  |  2.3 KB  |  61 lines

  1. Newsgroups: comp.sys.sun.admin
  2. Path: sparky!uunet!charon.amdahl.com!pacbell.com!mips!sdd.hp.com!usc!rpi!newsserver.pixel.kodak.com!laidbak!tellab5!balr!clrcom!lbr
  3. From: lbr@clear.com (Lon Ricker)
  4. Subject: SP/C - silo overflow
  5. Message-ID: <Bt8zzF.E50@clear.com>
  6. Organization: Clear Communications, Inc.
  7. Date: Wed, 19 Aug 1992 20:38:02 GMT
  8. Lines: 51
  9.  
  10. The following messages are appearing in /var/adm/messages on
  11. one (two?) of our customer's machines.
  12.  
  13. From the time stamps, it appears as though software controlling
  14. these ports may be seeing what it thinks is a "Ring Indication"
  15. (DCD going high) at the same time this occurs.
  16.  
  17. The messages are:
  18.  
  19.  
  20. Aug 18 07:14:52 iscclr vmunix: PUTSILO: unit 0 line 1 soft silo overflow
  21. Aug 18 09:02:53 iscclr vmunix: PUTSILO: unit 0 line 6 soft silo overflow
  22. Aug 18 09:33:19 iscclr vmunix: stc_drainsilo: unit 0 line 6 punting after 10 put retries
  23. Aug 18 11:18:22 iscclr vmunix: stc_drainsilo: unit 0 line 4 punting after 10 put retries
  24. Aug 18 11:53:37 iscclr vmunix: stc_drainsilo: unit 0 line 4 punting after 10 put retries
  25. Aug 18 12:11:34 iscclr vmunix: PUTSILO: unit 0 line 2 soft silo overflow
  26. Aug 18 12:13:19 iscclr vmunix: PUTSILO: unit 0 line 2 soft silo overflow
  27. Aug 18 12:44:30 iscclr vmunix: PUTSILO: unit 0 line 6 soft silo overflow
  28. Aug 18 12:44:45 iscclr last message repeated 3 times
  29.  
  30.  
  31. Unit 0 is the SP/C card (Sun SBus port expander) and the "line" numbers
  32. are the serial port numbers.
  33.  
  34. We see only the stc_drainsilo messages at one of the customer sites.
  35.  
  36. The configuration is:
  37.  
  38. Sparc1+ clone (CompuAdd) and IPC
  39. Sbus Port Card, running Version 1.1 with patch 100464_01
  40. Ports are attached to a TS1000 (NET's StatMux, now called SPX5)
  41.     running at 9600 baud.
  42.  
  43. The SBus cards attached to modems running at 2400 baud do NOT seem to 
  44. experience the same problems, so could it be that the TS1000 is 
  45. sending garbage to the SP/C card, or the SP/C card can't handle the
  46. speed of the TS1000?  As you can see, these messages are sporadic, as 
  47. we "talk" thru these ports multiple times (10-20) every hour.
  48.  
  49. I've used the new SunSolve CD to search bugs/patches and common problems,
  50. as well as looked at the Patch List recently posted.  Due to various
  51. hardware/software vendors involved, we not sure who should be called in.
  52.  
  53. Any insight, suggestions, (or even fixes???) would be greatly
  54. appreciated.
  55.  
  56. Lon Ricker
  57. lbr@clear.com
  58. Clear Communications Corp.
  59. (708) 317-2500
  60.  
  61.