home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1993 #1 / NN_1993_1.iso / spool / sci / physics / fusion / 3183 < prev    next >
Encoding:
Internet Message Format  |  1993-01-07  |  1.4 KB

  1. Path: sparky!uunet!dtix!darwin.sura.net!gatech!usenet.ins.cwru.edu!agate!rsoft!mindlink!a752
  2. From: Bruce_Dunn@mindlink.bc.ca (Bruce Dunn)
  3. Newsgroups: sci.physics.fusion
  4. Subject: Re: Status #7 Cell 4A3
  5. Message-ID: <19336@mindlink.bc.ca>
  6. Date: 7 Jan 93 16:11:37 GMT
  7. Sender: news@deep.rsoft.bc.ca (Usenet)
  8. Organization: MIND LINK! - British Columbia, Canada
  9. Lines: 25
  10.  
  11. > DROEGE@fnald.fnal.gov writes:
  12. >
  13. > ...
  14. > temperature range we are operating with the shell servo off and floating.
  15. > A
  16. > curious observation is that we are more sensitive to the outside air
  17. > temperature than to the room temperature.  So while the room temperature is
  18. > relatively constant, the calorimeter "sees" the outside through the dewar,
  19. > 1
  20. > 1/2" of foam, a (now) floating aluminum radiation shield, 1 1/2" foam, 10'
  21. > of
  22. > air, and an R19 house wall or R30 roof.
  23.  
  24.  
  25.         Is is possible that your apparatus is not directly "seeing" the
  26. outside temperature, but seeing the effect of cold weather on the power
  27. supply to your house.  Cold outside temperatures will result in greater power
  28. draws by people using electrical heating, and may give altered line voltages
  29. and possibly increased line transients as kilowatt sized units in neighboring
  30. houses switch on and off under thermostatic control.  Is there any part of
  31. the apparatus which is not operated of highly regulated, filtered power?
  32.  
  33.  
  34. --
  35. Bruce Dunn    Vancouver, Canada   Bruce_Dunn@mindlink.bc.ca
  36.