  1. Newsgroups: comp.sys.palmtops
  2. Path: sparky!uunet!psinntp!newsserver.pixel.kodak.com!laidbak!tellab5!vpnet!cgordon
  3. From: cgordon@vpnet.chi.il.us (gordon hlavenka)
  4. Subject: Re: external power on 95
  5. Message-ID: <1993Jan8.185922.26895@vpnet.chi.il.us>
  6. Organization: Vpnet Public Access
  7. References: <61849@aurs01.UUCP> <1ii9pbINNlgn@uwm.edu> <1993Jan7.232406.13117@noose.ecn.purdue.edu>
  8. Distribution: comp
  9. Date: Fri, 8 Jan 1993 18:59:22 GMT
  10. Lines: 38
  11.  
  12.  fritzj@gauss.ecn.purdue.edu (Fritz Friedlaender) writes:
  13. >There has been much duscussion on power supply voltages for the HP95LX,
  14. >... the HP95LX, with
  15. >1MB, draws about 4.5mA when off (measured on my unit - what are your
  16. >values?) from the external power supply.
  17. >I am looking for a number of responses, to help settle this question.
  18. >After you measure the open-circuit voltage, tell us whether disaster
  19. >ensued if you now discover that it is well over 12V.
  20.  
  21. I did some tests using the power supply from a Practical Peripherals
  22. 2400bps modem.  This supply is rated 9vac, 800mA.  Open circuit
  23. voltage was measured at 10.2vac, and did not drop significantly during
  24. my tests.
  25.  
  26. Power on, displaying TOPCARD:        20 mA
  27. Power off:                6.2 mA
  28. Running IR95 (EXM):            26 mA*
  29. Running IR95 (EXE):            24 mA*
  30. Transmitting a code with IR95:        80 mA
  31. Sitting at a DOS prompt:        76 mA
  32.  
  33. * There was a definite, repeatable 2mA difference between the EXM and
  34. EXE versions of IR95.  Go figger.
  35.  
  36. Also, typing 'serctl /o' at the DOS prompt did not decrease power
  37. consumption.
  38.  
  39. I tried to take some readings on internal power, but my cheapo ammeter
  40. apparently drops the voltage too much.  I had "Main battery low"
  41. readings, spontaneous shutdowns, "Exiting backup mode" messages,
  42. reboots, etc galore.  Probably dozens of each.  And didn't lose any
  43. data from anything.  I'll get a small, precision resistor and try
  44. again.
  45.  
  46. -- 
  47. ----------------------------------------------------
  48. Gordon S. Hlavenka           cgordon@vpnet.chi.il.us
  49. Vote straight ticket Procrastination party Dec. 3rd!
  50.