home *** CD-ROM | disk | FTP | other *** search
- Newsgroups: comp.dcom.modems
- Path: sparky!uunet!gatech!darwin.sura.net!wupost!csus.edu!netcom.com!wolfgang
- From: wolfgang@netcom.com (Wolfgang Henke)
- Subject: Re: HELP: Digicom Scout+ and kermit
- Message-ID: <1993Jan6.175128.1246@netcom.com>
- Organization: Netcom
- X-Newsreader: Tin 1.1 PL5
- References: <24625@hacgate.SCG.HAC.COM>
- Date: Wed, 6 Jan 1993 17:51:28 GMT
- Lines: 66
-
- Bill Neisius (bill@solaria) wrote:
- : : at*o
- : : MODEL:SCOUT PLUS
- : : DTE: 57600 N81
- : : DCE: 14400 V42b
- : : RECEIVE LEVEL= -36 DBM
- : :
- : : E1 K1 M1 Q0 V1 X4 TONE
- : : &B0 &C1 &D3 &R2 &T5
- : : *E1 *F3 *G1 *M2 *N2 *P0 *Q3 *S1 *T1
- : :
- : : S00=001 S04=010 S08=002 S15=255
- : : S01=000 S05=008 S09=000 S18=000
- : : S02=043 S06=002 S10=003 S25=000
- : : S03=013 S07=090 S12=050 S26=000
- : : OK
- :
- : That's strange... I thought *E1 was 'Auto reliable MNP5', yet the DCE shows
- : a V42b connection. And isn't *N2 'Modem connect rate=4800'? How did it
- : connect at 14400?
-
- You are right. I took the at*o from the Scout.txt file since it was the
- only place I had it handy. Then I corrected some settings in the output.
- Here is the original from Scout.txt:
-
- --------- begin inclusion -----------
-
- How does one call under severly impaired line conditions? Here
- is an an example calling to JV Dialogue in Moskow via direct
- dialing from Palo Alto, CA.
-
- SysOp: Pete Kvitek <kvitekp@jvd.msk.su>
-
- Online to JV Dialogue, Moskow:
- at*o
- MODEL:SCOUT PLUS
- DTE: 57600 N81
- DCE: 4800 MNP4 <-- V.32 at 4800 bps requires 16 db S/N only
- RECEIVE LEVEL= -36 DBM
-
- E1 K1 M1 Q0 V1 X4 TONE
- &B0 &C1 &D3 &R2 &T5
- *E1 *F3 *G1 *M2 *N2 *P0 *Q3 *S1 *T1 <-- *Q3 allows the modem full line
- quality control
- S00=001 S04=010 S08=002 S15=255
- S01=000 S05=008 S09=000 S18=000
- S02=043 S06=002 S10=003 S25=000
- S03=013 S07=090 S12=050 S26=000 <-- S07 is doubled to 90 seconds to
- OK allow for the long dial completion
- ato delay
- CONNECT 4800
- EC/MNP4 <-- with ato I go back from local modem
- to online JV Dialogue
- Created : 05-12-1992
-
- I use V.32 with fallback to 4800 bps, because this protocol
- requires only 16 dbm signal-to-noise. It is not often that one
- can get through to Moskow, and when I do I want to be sure to
- connect.
-
- -------- end of inclusion -------------
-
- --
- _________________________________________________________________________
- Wolfgang Henke Data lanes not car pool lanes wolfgang@netcom.com
-
-