- Newsgroups: comp.unix.aix
- Path: sparky!uunet!ornl!zhang
- From: zhang@dmnds.ms.ornl.gov (Xiaoguang Zhang)
- Subject: Re: LEDs flash 223 and 229 when installing new disk. Any advise?
- In-Reply-To: <1992Nov20.213438.11785@ncar.ucar.edu>
- Message-ID: <1992Nov22.192730.16039@ornl.gov>
- Sender: usenet@ornl.gov (News poster)
- Reply-To: zhang@dmnds.ms.ornl.gov (Xiaoguang Zhang)
- Organization: Oak Ridge National Laboratory
- Distribution: usa
- Date: Sun, 22 Nov 1992 19:27:30 GMT
- Lines: 7
-
- I tried to send e-mail twice and was unsuccessful. So I have to post this.
-
- I have seen the alternating 223 and 229 on LED when I tried to add
- an external disk whose SCSI id was not changed and was 0 which conflicted
- with one of the internal drives. How did you connect the new drive? I
- would not try to connect a new SCSI device while the machine is on. You
- never know what will happen. Hope my info helps.
-