home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #27 / NN_1992_27.iso / spool / comp / sys / sun / hardware / 5786 < prev    next >
Encoding:
Internet Message Format  |  1992-11-20  |  1.9 KB

  1. Xref: sparky comp.sys.sun.hardware:5786 comp.periphs.scsi:5569
  2. Newsgroups: comp.sys.sun.hardware,comp.periphs.scsi
  3. Path: sparky!uunet!usc!zaphod.mps.ohio-state.edu!darwin.sura.net!mlb.semi.harris.com!controls.ccd.harris.com!cone
  4. From: cone@controls.ccd.harris.com (Tom Cone)
  5. Subject: Re: Problems with Fast SCSI-II on Sun Sparc 10 (long)
  6. Message-ID: <1992Nov20.132944.7720@ccd.harris.com>
  7. Sender: usenet@ccd.harris.com
  8. Organization: Harris Controls and Composition
  9. References: <MRD.92Nov13160506@morsel.stdavids.picker.com> <1992Nov15.121008.12717@pt.com> <1992Nov17.100038.27178@panix.com>
  10. Date: Fri, 20 Nov 1992 13:29:44 GMT
  11. Lines: 28
  12.  
  13. In article <1992Nov17.100038.27178@panix.com> alexis@panix.com (Alexis Rosen) writes:
  14. >I remember some discussion of FPT when IBM first introduced it. I seem to
  15. >recall that there was mention of some potential problems with FPT too.
  16. >
  17. >However... Assuming FPT is the solution we seek, where do we go about
  18. >terminating a Sparcstation 2? Obviously, the external end of the chain, but
  19. >what about inside the box? I have yet to get a straight answer as to where
  20. >(if anywhere) the internal part of the SCSI bus is terminated (I suspect that
  21. >it isn't but have no real basis on which to judge).
  22. >
  23.  
  24. 1. The internal drive is terminated at the drive. SUN does it like IBM's
  25.    internal/external controller. Terminate the external on the last device.
  26. 2. Aeronics sells the FPT's. Depending on quanity around $40.
  27. 3. Aeronics is working on an all line FPT. Should work even better than
  28.    the three line.
  29. 4. Yes FPT works on SCSI-1 and SCSI-2.
  30. 5. In answer to someone elses question. The thru-put on the SCSI bus drops
  31.    off after the fourth device. This is what we have seen in our tests
  32.    on SCSI-1 and SCSI-2.
  33. 6. For FPT to work best it needs to installed at both ends of the bus.
  34.    We have seen much better results than passive termination by just
  35.    putting a FPT at the end though.