home *** CD-ROM | disk | FTP | other *** search
- Newsgroups: comp.sys.novell
- Path: sparky!uunet!s5!is1.is.morgan.com!is.morgan.com!mpiet
- From: mpiet@is.morgan.com (Mark Pietrasanta)
- Subject: Re: Workstation Error w/SysCon & FConsole
- Message-ID: <1992Nov19.120442@is.morgan.com>
- Sender: news@is.morgan.com
- Nntp-Posting-Host: is11
- Organization: Morgan Stanley - IS
- References: <1992Nov19.002112.20070@photon.com>
- Date: Thu, 19 Nov 1992 17:04:42 GMT
- Lines: 45
-
- In article <1992Nov19.002112.20070@photon.com>, juanman@photon.com (Juan Castaneda) writes:
- |>
- |> Question: I am getting the following error when trying to run
- |> SysCon & FConsole from one specific workstation under ver. 3.11:
- |>
- |> "run-time error R6002
- |> - floating point not loaded"
- |>
- |> The PC is a 386-25MHZ and I have already tried replacing the NIC.
- |> I've been able to run these two utilities a couple of times, but
- |> this is only about 5% of the time.
- |>
- |> Any tips or insight would be greatly appreciated.
- |>
- |> Thanks in advance,
- |>
- |>
- |> Juan Manuel Castaneda
- |> Photon Research Associates, Inc.
- |> La Jolla, California
-
- Virus! Virus!
-
- Maybe not. Is this some fourth party clone? It may be
- a bum machine (the NIC shouldn't cause this).
-
- If you have time, try low-level formatting the hard disk,
- and don't install any TSR's or anything else - just the
- NetWare shells. Then, if it doesn't happen anymore, add
- the TSR's one by one and see what happens.
-
- Basically, it's either a Virus, and bum machine, or a conflict
- with one of the TSR's (including memory manager) that you have
- loaded.
- --
- Mark Pietrasanta - mpiet@is.morgan.com
- * * * * * * * * *
-
- "Great spirits have always encountered violent opposition from
- mediocre minds." - Albert Einstein
-
- ----------------------------------------------------------------
- Disclaimer: These responses are my own and in no way reflect the