  1. Newsgroups: comp.sys.sgi
  2. Path: sparky!uunet!zaphod.mps.ohio-state.edu!mips!odin!fido!zola!zuni!anchor!olson
  3. From: olson@anchor.esd.sgi.com (Dave Olson)
  4. Subject: Re: SCSI cable length
  5. Message-ID: <nm711j4@zuni.esd.sgi.com>
  6. Sender: news@zuni.esd.sgi.com (Net News)
  7. Organization:  Silicon Graphics, Inc.  Mountain View, CA
  8. References: <31493@adm.brl.mil> <nkf86oc@zuni.esd.sgi.com> <2817@contex.contex.com>
  9. Date: Fri, 24 Jul 92 02:58:10 GMT
  10. Lines: 31
  11.  
  12. In <2817@contex.contex.com> brian@garbo.contex.com (Brian Love) writes:
  13. ...
  14. | We push the limit on SCSI cable lengths and consequently see a fair number
  15. | of SCSI errors.  We've been trying to nail down as accurately as possible
  16. | what the usable SCSI bus length is.  The January/February issue of Pipeline
  17. | says "On a Personal IRIS or Magnum system, the internal SCSI cables are
  18. | approximately 8 feet long, ..."  (Adding a SCSI Peripheral to an IRIS
  19. | System, pg.  12).  Is this a correct figure?  How long is the SCSI cabling
  20. | inside other boxes, such as an Expansion Cabinet, an Indigo, and a Crimson?
  21.  
  22. 8 feet is worst case, or it may be the sum of a PI and a Personal File
  23. (PI chassis, but just for up to 4 drive modules).  The worst case length
  24. was some of the early PI's at just over 5 feet of cable internally.
  25.  
  26. | We've also seen bad SCSI cables.  On one of our systems, swapping SCSI
  27. | cables of the same length but different vendor completely solved a
  28. | not-so-intermittent parity error on the SCSI bus.  A cable-tester showed no
  29. | connectivity problems in the bad cable.  Are there any reliable ways to
  30. | tell a good SCSI cable from a bad SCSI cable?
  31.  
  32. You could use a TDR to do some checking.  Also watch out for the
  33. wrong gauge wires, or not bothering to connect all the ground wires.
  34.  
  35. Finally, for cables that are twisted pair, the folks doing the SCSI
  36. specs did some testing, and found that certain cable designs (certain
  37. pairs in the center) would work better than others, for reasons that
  38. escape me at the moment.