home *** CD-ROM | disk | FTP | other *** search
- Path: sparky!uunet!cis.ohio-state.edu!ucbvax!agate!rsoft!mindlink!a302
- From: Richard_Parson@mindlink.bc.ca (Richard Parson)
- Newsgroups: comp.dcom.modems
- Subject: Re: Supra V.32bis/Maximus
- Message-ID: <13901@mindlink.bc.ca>
- Date: 31 Jul 92 05:20:18 GMT
- Organization: MIND LINK! - British Columbia, Canada
- Lines: 42
-
- > Michael J. Farquharson writes:
- >
- > Msg-ID: <1992Jul26.23551, 26 Jul 1992 23:55:1
- >
- > Well, I got my new modem... it's a SupraFaxModem... it arrived in
- > less than 2 weeks (and I'm in Canada) straight from Supra... not bad.
- >
- > However, I've got a few problems with it... I run a BBS under
- > Maximus 2.01 and things are not working 100%. It started out so that no
- > one could even connect to the thing unless they had another 'faster than
- > 2400 baud' modem, which amounts to about 1 person here on P.E.I., but I
- > fixed that. Now, the major problem I have is this... when users call up
- > my board... they are losing some of the characters... namely the ones at
- > the beginning of the transmission... Like they lose the top two lines of
- > a Menu but pick up half way through.... I guess anything that starts at
- > the top of a screen just doesn't all come through.
- >
- > Now, I know that I'm connected at 2400 with them, I know that from
- > the cute little display that flashes '24' at me. So.... what am I doing
- > wrong. Here's my Init String, I made it up generally by myself with some
- > assistance from the very adequate manuals that accompanied the modem:
- >
- > AT&F2&Y0E0M0V1S0=0 (Right? Wrong? I'm no expert, but it answers!)
- >
- > Also, I have my Baud Maximum set to 19200baud.... but the modem will
- > actually only do 14.4k with max throughput of 57.6k... should I set it to
- > one of these instead? Oh yeah, I have CTS/DSR enabled, I don't REALLY know
- > what those are either... but Maximus suggests that for faster than 9600 you
- > really should enable them.
- >
- > Finally, when a call comes in, Maximus says that it's connected at
- > 19200.... even though it's only at 2400? Any idea why? Any help would be
- > greatly appreciated. The sooner the better as I'd like to get this puppy
- > working ASAP. Thanks a lot
- >
- >
- > ===============================================================================
- > stmfarqu@upei.ca | Sysop: Starbase 1 BBS, Sherwood, P.E.I., Canada
- > Michael Farquharson | Phone: (902)-628-1230
- > UPEI Engineering | Running Maximus with Supra V.32bis modem!!!
- >
- > ===============================================================================
-