  1. Newsgroups: comp.dcom.modems
  2. Path: sparky!uunet!protocol.com!farzin
  3. From: farzin@protocol.com (Farzin Guilak)
  4. Subject: Problems with T1600 - T2500 communication
  5. Message-ID: <1992Jul23.190102.766@protocol.com>
  6. Sender: usenet@protocol.com
  7. Nntp-Posting-Host: happy
  8. Organization: Protocol Systems, Incorporated
  9. Date: Thu, 23 Jul 1992 19:01:02 GMT
  10. Lines: 40
  11.  
  12.     I have had a lot of problems and only limited success in 
  13.     getting a T1600 to communicate with a T2500.  The T2500
  14.     is configured in its default mode.
  15.  
  16.     The T1600 differs from default in the following settings
  17.     and registers (I'm including all differences for 
  18.     completeness):
  19.  
  20.     &C2 - DCD Control. DCD always on except at disconnect.
  21.     &D3 - DTR Interpretation. Reset when DTR switched off.
  22.     
  23.     S0=1    - Auto Answer.  Number of rings.
  24.     S25=15  - DTR Delay Timing.  150 msec.
  25.     S26=0   - RTS to CTS Delay Interval.
  26.     S50=6   - Modulation Speed.  9600 Baud, V.32.
  27.     S51=5   - DTE Interface Speed.  19200 bps.
  28.     S58=2   - DTE Flow Control.  Full duplex RTS/CTS.
  29.     S61=0   - Local Action on Break.  Go to command mode.
  30.     S68=2   - DCE Flow Control.  Full duplex hardware flow control.
  31.     S111=30 - File Transfer Protocol.  UUCP 'g' protocol.
  32.     S180=3  - Error Control Request.  MNP
  33.  
  34.     
  35.     I originally had S50=0 (for automatic speed determination),
  36.     but this did not seem to work at all.  After changing it to
  37.     S50=6 (9600, V.32), it works on one out four or five attempts.
  38.     I talked with tech support at Telebit, and they suggested 
  39.     setting error control for the T2500 (S95=2, S97=1, S106=1).
  40.     However, these settings caused problems on the T2500 and were
  41.     abandoned.
  42.  
  43.     Any help or suggestions would be greatly appreciated.
  44.  
  45.     Please email responses to:  farzin@protocol.com
  46.  
  47.  
  48. --
  49. farzin@protocol.com
  50. (503) 526-4389
  51.  
  52.