  1. -------------------------------------------------------------------------------
  2.                              Gateway Operations
  3. -------------------------------------------------------------------------------
  4.  
  5.  
  6. Setup for Incoming Gateway (user calling into the LAN)
  7.  
  8. Only the Norton pcANYWHERE LAN supports Gateway Operations. To set-up an
  9. incoming gateway for callers to call INTO the Network, set-up the gateway
  10. machine as follows:
  11.  
  12. 1.    From the DOS prompt, load the appropriate network drivers ( IPX
  13.     or NETBIOS).
  14.  
  15. 2.    From the Norton pcANYWHERE LAN Main Menu,
  16.  
  17.      a. Select "Gateway Operation".
  18.      b. Select "Incoming Configuration" and select the Hardware Configuration
  19.         that matches the gateway machine's modem.
  20.      c. Press ESC when you've chosen the correct configuration and save any
  21.         changes that were made.
  22.      d. From the Gateway Main Menu, select "Outgoing Configuration" and select
  23.         the Hardware Configuration that matches your network protocol (IPX or
  24.         NETBIOS).
  25.      e. Confirm that the "Use Gateway" field is set to No.
  26.      f. Press ESC when you've chosen the correct configuration and save any
  27.         changes that were made.  
  28.      g. From the Gateway Main Menu, select "Activate Gateway"
  29.  
  30. The Gateway is now active.  Any Remote user can now call into the Gateway
  31. modem (Incoming Configuration) and attach to any Host that is available on
  32. the Network via the Network protocol (Outgoing Configuration).
  33.  
  34.  
  35. Setup pcANYWHERE Hosts for access through the Gateway
  36.  
  37. To set up Host workstations that callers may attach to through the Gateway,
  38. set-up the Host machine as follows:
  39.  
  40. 1.    From the DOS prompt, load the appropriate network drivers ( IPX or
  41.     NETBIOS).
  42.  
  43. 2.    From the Norton pcANYWHERE LAN Main Menu
  44.     
  45.      a. Select "Host Operation"
  46.      b. Select "Active Configuration" and select the Hardware Configuration
  47.         that matches the network protocol (IPX or NETBIOS).  
  48.      c. Confirm that the "Use Gateway" field is set to No.
  49.      d. Press ESC when you've chosen the correct configuration and save any
  50.         changes that were made.  
  51.      e. From the Host Main Menu, select "Begin Host Operation" then select
  52.         "Wait for a connection".
  53.  
  54. Remote users can now call into the Gateway machine and attach to this
  55. Host workstation.
  56.  
  57. Setup for Outgoing Gateway (call into the LAN)
  58.  
  59. To set-up an outgoing gateway for callers to call OUT OF the Network, set-up
  60. the gateway machine as follows:
  61.  
  62. 1.    From the DOS prompt, load the appropriate network drivers ( IPX or
  63.     NETBIOS).
  64.  
  65. 2.    From the Norton pcANYWHERE LAN Main Menu
  66.     
  67.      a. Select "Gateway Operation".
  68.      b. Select "Incoming Configuration" and select the Hardware
  69.         Configuration that matches the network protocol (IPX or
  70.         NETBIOS).  
  71.      c. Confirm that the "Use Gateway" field is set to No.    
  72.      d. Press ESC when you've chosen the correct configuration and
  73.         save any changes that were made.  
  74.      e. From the Gateway Main Menu, select "Outgoing Configuration"
  75.         and select the Hardware Configuration that matches the gateway
  76.         machine's modem.
  77.      f. Press ESC when you've chosen the correct configuration and save
  78.         any changes that were made.  
  79.      g. From the Gateway Main Menu, select "Activate Gateway".
  80.  
  81. The Gateway is now active.  Any Remote on the Network can now attach to the
  82. Gateway machine through the network protocol (Incoming Configuration) and
  83. attach to any external Host that is available (Outgoing Configuration).
  84.  
  85. To set up Remote workstations for outbound calls through the Gateway, set-up
  86. the Remote machine as follows...
  87.  
  88. 1.    From the DOS prompt, load the appropriate network drivers ( IPX or
  89.     NETBIOS).
  90.  
  91. 2.    From the Norton pcANYWHERE LAN Main Menu,
  92.  
  93.      a. Select "Remote Operation".
  94.      b. Select "Connect Via List of Hosts" and choose "ANYWHERE host via
  95.         IPX/NetBIOS", depending on your network protocol.
  96.      c. Select "View/Modify Host Entry" and press  ENTER twice.  
  97.      d. At the Configuration screen for that particular setup.  Set the
  98.         "Device/Port" field to "Netware IPX" or "NetBIOS" and set the "Use
  99.          gateway" field to "Yes".
  100.      e. Press ESC when you've chosen the correct configuration and save any
  101.         changes that were made.  
  102.      f. Press ESC once more.  You should now be back to the Connect Options
  103.         Menu.
  104.      g. Select "Call" and select the Gateway you wish to attach to.
  105.  
  106. You are now attached to the Gateway's modem.  At this point, the Norton
  107. pcANYWHERE will prompt you for the phone number you wish to call.  Once
  108. that number is entered, the Gateway's modem will dial the number specified.