home *** CD-ROM | disk | FTP | other *** search
/ The World of Computer Software / World_Of_Computer_Software-02-385-Vol-1of3.iso / s / stac0193.zip / TEC043.DOC < prev   
Text File  |  1993-01-20  |  3KB  |  55 lines

  1. ___________________________________________________________________________
  2. STACKER NOTE                                                   STACKER NOTE
  3. Subject:  Stacker 3.0 Compatibility with Microsoft Access
  4. STACKER NOTE #043 - 01/20/93                           STAC FAX Index #3004
  5. ___________________________________________________________________________
  6.  
  7. Background.
  8.  
  9. Through  recent message threads on CompuServe Information  System (CIS) 
  10. between the Microsoft Access Test Group and a user, it  was reported that 
  11. Stac  Electronics' Stacker 3.0 product had incompatibilities  with  
  12. Microsoft's  Access  database program.  These message threads were the 
  13. result of a mis-interpretation  of an error message generated by Stacker's 
  14. CHECK program when  run with  an  undocumented  engineering  switch. The use  
  15. of the engineering  switch and it's mis-interpreted output  are  further 
  16. explained in STACKER NOTE #s 041 and 042 (STAC FAX Index #s 3002 and 3003.)   
  17. The engineering switch was recommended for use by Stac  Technical  Support 
  18. only as a temporary  work-around  for  a condition unrelated to compatibility 
  19. with Microsoft Access, while Stac addressed a more permanent solution.
  20.  
  21. Result.
  22.  
  23. After further discussions between Microsoft and Stac Electronics, a follow-up 
  24. clarification message was posted on CompuServe by the Microsoft Access Test 
  25. Group which states: 
  26.  
  27.     "It  turns out that there was a misunderstanding  on  my
  28.     part  regarding the severity of the problem.  The  'lost
  29.     sector  groups' errors being reported by 'CHECK /=D  /F'
  30.     are  100%  benign.  The Access files are not corrupt  in
  31.     any  way.   My  understanding is that these undocumented
  32.     CHECK  switches  are low level internal debugging  tools
  33.     for  use  by their developers.  When used with  /=D  /F,
  34.     CHECK  is  very  zealous about reporting *all*  possible
  35.     problems,  no  matter  how benign.   It  will  sometimes
  36.     return  messages  that imply that  files  are  corrupted
  37.     when  they  really  aren't.  This is what  is  happening
  38.     with  Access  files.  I really want to put the  question
  39.     of  Access/Stacker 3.0 'incompatibility' to rest.  'Lost
  40.     sector  group' error messages from 'CHECK  /=D  /F'  are
  41.     not real errors, and should be completely ignored."
  42.  
  43. As  a result of the discussions between Stac  Electronics  and Microsoft,  
  44. it  was  confirmed that there  are  NO  compatibility problems between 
  45. Stacker 3.0 and Microsoft Access.
  46.  
  47.  
  48.  
  49.  
  50.  
  51.  
  52.  
  53. ___________________________________________________________________________
  54. Copyright 1993, Stac Electronics
  55.