home *** CD-ROM | disk | FTP | other *** search
/ ftp.msan.hr / ftp.msan.hr.tar / ftp.msan.hr / Drivers / HP / Server / ml150g2supportCD.nrg / Utility / Tools / ml150winasm-2.12.00build811-1.exe / data1.cab / _B33FB6E5337748E99EC925565101EF6A < prev    next >
Text File  |  2004-07-16  |  2KB  |  62 lines

  1. <!doctype html public "-//w3c//dtd html 4.0 transitional//en">
  2. <html>
  3. <head>
  4. <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
  5. <title>Message background and recovery options</title>
  6. <base target="_top">
  7. <link rel="stylesheet" href="basicpg.css">
  8. </head>
  9. <body text="#000000" bgcolor="#FFFFFF" link="#0000FF" vlink="#333399" alink="#0000FF">
  10. <h1>Set drive to failed: controller [number], <<em>device location</em>></h1>
  11. <h2>Explanation:</h2>
  12.  
  13. <p>One of the following occurred:</p>
  14. <ul>
  15.   <li>The user has removed or rearranged the specified physical drive.</li>
  16.   <li>A controller might be configured with unattended mode. Changes to the RAID
  17.     configuration are accepted automatically in unattended mode.</li>
  18.   <li>There was an error in communication between the physical drive and the controller.</li>
  19. </ul>
  20. <p><b><img src="images/note.gif" width="15" height="17"> Note:</b> (Clustering
  21.   and failover environments only) If you move a logical device to another
  22.   controller, these entries might be normal.</p>
  23.  
  24. <h2>Action:</h2>
  25.  
  26. <ol>
  27.   <li>Verify that there is power to external enclosures and connections. </li>
  28.   <li>Verify that cables are properly seated.</li>
  29.   <li>Check for damaged, bent, or pushed pins on the following:
  30.     <ul>
  31.       <li>Termination (for non-backplane systems)</li>
  32.       <li>Backplanes</li>
  33.       <li>Physical drives</li>
  34.       <li>Controller</li>
  35.     </ul>
  36.   </li>
  37. </ol>
  38. <p>If you cannot identify a connection problem, the replacement order for parts
  39.   is the following:
  40. <ol>
  41.   <li>Termination (for non-backplane systems)</li>
  42.   <li> Cables</li>
  43.   <li>Physical drives</li>
  44.   <li>Backplanes</li>
  45.   <li>Controller</li>
  46. </ol>
  47. <p>Before replacing a physical drive or controller, verify that it is updated
  48.   with the latest firmware (microcode) and that they still fail. <br>
  49.   <br>
  50.   <b><img src="images/note.gif" width="15" height="17"> Note:</b> If multiple
  51.   physical drives are marked failed within the same time period, check the cables
  52.   and backplanes.
  53.  
  54. <div align="center">
  55.   <hr>
  56.   <a href="gportal.htm">Glossary</a> | <a href="menutoc.htm">Contents</a></div>
  57. <p> </p>
  58. <p align="right">x-0189-ASM-00-06-EN </p>
  59.  
  60. </body>
  61. </html>
  62.