home *** CD-ROM | disk | FTP | other *** search
/ ftp.msan.hr / ftp.msan.hr.tar / ftp.msan.hr / Drivers / HP / Server / ml150g2supportCD.nrg / Utility / Tools / ml150winasm-2.12.00build811-1.exe / data1.cab / _362A6CBD19D141BD83158EB110579531 < prev    next >
Text File  |  2004-07-16  |  4KB  |  98 lines

  1. <!doctype html public "-//w3c//dtd html 4.0 transitional//en">
  2. <html>
  3. <head>
  4.  
  5. <meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
  6.  
  7.  <title>Setting a drive state to failed</title>
  8.  
  9. <base target="_top">
  10. <link rel="stylesheet" href="basicpg.css">
  11. </head>
  12. <body text="#000000" bgcolor="#FFFFFF" link="#0000FF" vlink="#333399" alink="#0000FF">
  13.  
  14.  <h1><img src="images/l_pdalrt.gif" alt="failed physical drive" width="40" height="28" align="absmiddle"><img src="images/l_pdfull.gif" width="28" height="28" align="absbottom">
  15.   Setting a drive state to failed</h1>
  16.  
  17. <p>You can use this action only on a physical drive that is part of a disk group.
  18.   If a physical drive is part of a disk group, you must change the drive state to
  19.   failed before removing the drive from the %SERVER% or enclosure. Doing so eliminates
  20.   the risk of losing data. After you replace the physical drive, you can rebuild
  21.   the affected disk group. </p>
  22. <p>This action is useful in situations such as the following: </p>
  23. <ul>
  24.   <li>You want to replace a physical drive that is marked with a <a href="gpfa.htm">S.M.A.R.T.</a>.
  25.     <br>
  26.     <br>
  27.   </li>
  28.   <li>You want to replace a physical drive that is unwarranted.<br>
  29.     <br>
  30.   </li>
  31. </ul>
  32. <dl>
  33.   <dt><b><img src="images/attentio.gif" width="22" height="15">Attention</b>:</dt>
  34.   <dd>
  35.     <ol>
  36.       <li>
  37.          <p>If you do <b>not</b> change an optimal physical drive state to failed
  38.           before removing the drive from the %SERVER% or enclosure, you risk losing
  39.           data or damaging the physical drive.</p>
  40.       <li>You cannot use this action on a physical drive undergoing a rebuild
  41.         operation.<br>
  42.         <br>
  43.       <li>(For <b>non</b>-RAID level-x0 logical drives) If you choose to use this
  44.         action and a logical drive is:
  45.         <ul>
  46.           <li>In a <a href="gcrt.htm">degraded</a> state, the logical drive state
  47.             <b>will</b> change to <a href="gofl.htm">failed</a>. </li>
  48.           <li>RAID level-0 and in an optimal state, the logical drive <b>will</b>
  49.             change to failed.</li>
  50.           <li>Not RAID level-0 and in an optimal state, the logical drive state <b>will</b>
  51.             change to degraded.<br>
  52.           </li>
  53.         </ul>
  54.       <li>(For RAID level-x0 logical drives) If you choose to use this action
  55.         and a logical drive is in a degraded state, <a href="ccrtx0.htm">the logical
  56.         drive state <b>might</b> change to failed</a>. </li>
  57.     </ol>
  58.   </dd>
  59. </dl>
  60. <ol>
  61.   <li>In the <a href="cusegui4.htm">Physical devices view</a>, click <img src="images/s_pdalrt.gif" alt="failed physical drive" width="20" height="15" align="absbottom">
  62.     (physical drive) or<img src="images/drive_fl.gif" width="28" height="20" align="absbottom">(physical
  63.     drive).<br>
  64.     <br>
  65.   </li>
  66.   <li> Right-click <b>Set drive state to failed</b>. A confirmation window opens
  67.     to warn that this action might corrupt data.<br>
  68.     <br>
  69.     <b><img src="images/note.gif" width="15" height="17"> Note:</b> If the logical
  70.     drive that contains this physical drive is already failed, the Adaptec Storage Manager
  71.     does not display this warning because the data is already corrupt.
  72.     Continue to step 4. <br>
  73.     <br>
  74.   </li>
  75.   <li>Click <b>Yes</b>. The Adaptec Storage Manager sets the drive status to <a href="gddd.htm">failed</a>.
  76.     <br>
  77.     <br>
  78.   </li>
  79.   <li>Replace the selected physical drive. If the logical drive is not failed,
  80.     <a href=arbddd.htm>manually rebuild</a> the logical device.</li>
  81. </ol>
  82. <h2>More information</h2>
  83.  
  84. <ul>
  85.   <li><a href="cpdarray.htm">Replacing physical drives in a disk group</a></li>
  86.   <li><a href="ccrtx0.htm">Understanding when RAID level-x0 logical drives change
  87.     state</a></li>
  88. </ul>
  89.  
  90. <div align="center">
  91.   <hr>
  92.   <a href="gportal.htm">Glossary</a> | <a href="menutoc.htm">Contents</a></div>
  93. <p> </p>
  94. <p align="right">x-0343-ASM-00-08-EN </p>
  95.  
  96. </body>
  97. </html>
  98.