home *** CD-ROM | disk | FTP | other *** search
/ Network Support Encyclopedia 96-1 / novell-nsepro-1996-1-cd2.iso / download / netware / ptf415.exe / 4X.TXT < prev    next >
Text File  |  1993-09-27  |  22KB  |  502 lines

  1.  
  2.               NOVELL TECHNICAL INFORMATION DOCUMENT
  3.  
  4. TITLE:              Installation of PTF 41X series on a 4.0X server
  5. DOCUMENT ID:        TID250012
  6. DOCUMENT REVISION:  A
  7. DATE:               23SEP93
  8. ALERT STATUS:       Yellow
  9. INFORMATION TYPE:   Issue
  10. README FOR:         NA
  11.  
  12. NOVELL PRODUCT and VERSION:
  13. NetWare for SAA 1.3
  14.  
  15. ABSTRACT:
  16. The installation instructions for PTF 410, PTF 411, PTF 414, and PTF 415 in
  17. a NetWare 4.0 or 4.01 server.
  18. _________________________________________________________________
  19.  
  20. DISCLAIMER
  21. THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL. 
  22. NOVELL MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION. 
  23. HOWEVER, THE INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION
  24. ONLY.  NOVELL MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS
  25. INFORMATION.
  26. _________________________________________________________________
  27.  
  28. ISSUE
  29.  
  30.   To Install on a NetWare 4.0 or 4.01 server.
  31.  
  32.   1. If you have not yet read PTF41X.TXT it is very importand that you do
  33. so.
  34.  
  35.   2. Bindery Emulation must be enabled on the NetWare 4.0x server on which
  36. NetWare for SAA 1.3 installed.  The SET BINDERY CONTEXT command in
  37. AUTOEXEC.NCF or STARTUP.NCF enables bindery emulation.  In addition, the
  38. NetWare 4.0x server must have a READ/WRITE, or master replica of its
  39. partition, in order for bindery emulation to be enabled.  Please refer to
  40. the NetWare 4 System Administration Guide.
  41.  
  42.   CAUTION: Do not change the Bindery Context (Bindery Emulation) once
  43. NetWare for SAA 1.3 is installed.  Doing so will require you to reinstall
  44. NetWare for SAA 1.3 again.
  45.  
  46.   3. Do not install SNMP on a NetWare 4.X server since it is already
  47. present on the system.
  48.  
  49.   4. To install the Communication Executive update, issue the following
  50. commands at the NetWare console:
  51.     a.  Type LOAD INSTALL <Enter>.
  52.     b.  Select Maintenance/Selective Install <Enter>.
  53.     c.  Select Product Options <Enter>.
  54.     d.  Press <Insert>.
  55.     e.  Enter the full pathname of the CEUPDATE directory.
  56.         Include \DISK1 at the end of the pathname, as shown in the example
  57. below:
  58.             volume:\SAA13\CEUPDATE\DISK1
  59.  
  60.   5. Perform a similar operation to install NetWare for SAA:
  61.     a.  Type LOAD INSTALL <Enter>.
  62.     b.  Select Maintenance/Selective Install <Enter>.
  63.     c.  Select Product Options <Enter>.
  64.     d.  Press <Insert>.
  65.     e.  Enter the full pathname of the NWSAAUPD directory.
  66.         Include \DISK1 at the end of the pathname, as shown in the example
  67. below:
  68.  
  69.             volume:\SAA13\NWSAAUPD\DISK1
  70.  
  71.   6.  After you have installed the Communication Executive and NetWare for
  72. SAA, check to make certain that your AUTOEXEC.NCF conforms to sample
  73. AUTOEXEC.NCF below.
  74.  
  75.   7. Down the server and restart it (with the SERVER command).  You must do
  76. this to ensure proper operation of the Communications Server after you have
  77. installed NetWare for SAA.
  78.  
  79.   Sample AUTOEXEC.NCF for NetWare 4.0
  80.   -----------------------------------
  81.   In this sample file, the same adapter card is used for both LAN and host
  82. access.  The lower-case entries indicate items that you must fill in with
  83. your own values (for the bindery context and the file server name and the
  84. IPX internal network number.)
  85.     SET BINDERY CONTEXT = bindery_context
  86.     FILE SERVER NAME file_server_name
  87.     IPX INTERNAL NET internal_network_number
  88.     LOAD CLIB
  89.     LOAD BTRIEVE -U=1 -P=4096 -F=20 -H=60 -L=20 -C
  90.     SET MAXIMUM PACKET RECEIVE BUFFERS=2000
  91.     ; LAN CONNECTION:
  92.     LOAD NE2000 INT=3 PORT=300 FRAME=ETHERNET_802.3
  93.     ; HOST CONNECTION:
  94.     LOAD NE2000 INT=3 PORT=300 FRAME=ETHERNET_802.2 NAME= xxxx
  95.     ; where xxxx is the Logical Adapter Name from CSCON
  96.  
  97.   INSTALLATION NOTES
  98.  
  99.   1. Remote Installation from a local server's diskette drive may cause
  100. problems.  If you attempt to do a remote installation and use the local
  101. server's diskette drives to install NWSAA 1.3 expect the following error
  102. message to appear in certain situations:
  103.  
  104.         "Error, BuildCDProductsList returned -1
  105.               Press Any Key To Continue."
  106.  
  107.      At this point installation of NWSAA will fail.  The problem is due to
  108. the fact that the diskette drive access is slow enough that the SPX
  109. connection established to the remote server will timeout, in which case the
  110. install process can't write to the PRODUCTS.DAT file thus causing this
  111. error message and install to fail.  This also depends on network traffic. 
  112. In some situations this remote install procedure from diskette will work
  113. with no problems.
  114.  
  115.      There are two possible solutions.
  116.      a. Remote installs should be done from DOS hard drive or NetWare
  117. volume if possible.
  118.      OR
  119.      b. Increase both the remote and local server's SPX timeout values,
  120. "SPX   WATCHDOG ABORT TIMEOUT" and "SPX ACK WAIT TIMEOUT", using
  121. SPXCONFG.NLM.  NMA for NetView (NetView Ready) experiences the same
  122. problems as above for remote installs from diskette drive.
  123.  
  124.   2. CSADMIN User for CSCON
  125.  
  126.      A user called CSADMIN is created automatically during the SAA
  127. installation.  This user has supervisor equivalent in the NW 3.11 sense, to
  128. the SAA server and may be used to configure the SAA server and run CSCON. 
  129. The password for CSADMIN is "NWSAA", you should use NWADMIN and change the
  130. password  after the SAA installation to maintain security.
  131.  
  132.      Creating a User Other than CSADMIN for CSCON
  133.      In order for a user to be able to log in to CSCON and configure the CS
  134. under NetWare 4.0, you must create a user under the Organizational Unit
  135. (context) where SAA has been installed.  The user must then be given
  136. 'Supervisor-Equivalent' rights (in the NetWare 3.11 sense).  This can be
  137. accomplished by making the user's security equivalent to the File Server 
  138. object.  The procedure below outlines how to do this, using the NWADMIN
  139. utility running on a workstation:
  140.     a. Log in as NetWork Administrator (Admin) to the NetWare 4.0 server.
  141.     b. Load NWADMIN from Windows.
  142.     c. Select the Organizational Unit (context) where SAA is installed.
  143.     d. Click on OBJECT from the NetWare Administrator screen.
  144.     e. Click on CREATE.
  145.     f. Select USER from the NEW OBJECT LIST, and click OK.
  146.     G. Fill in the user information, login name, and last name; then select
  147. the ADDITIONAL PROPERTIES box and click OK.
  148.     h. Click on the PASSWORD RESTRICTIONS box on the right of the screen;
  149. check the REQUIRE PASSWORD box and click on the CHANGE PASSWORD bar.  Type
  150. the password in both boxes, and click OK.
  151.     i. From the same screen, click on the SECURITY EQUIVALENCIES box in the
  152. right lower corner of the screen.
  153.     j. Click on the ADD box, and select the FILE SERVER OBJECT where SAA is
  154. installed from the OBJECTS LIST.  Click OK.
  155.     The file server object will now be shown in the SECURITY EQUAL TO window. 
  156. Click OK to exit.
  157.     k. The user just generated will now be able to log in to the server and
  158. run CSCON to configure SAA service profiles.
  159.  
  160.   3. Load Information
  161.     a. OS Ring Protection
  162.     NetWare for SAA 1.3 can only be loaded and executed in the OS Domain at
  163. Ring 0 under NetWare 4.0.  NetWare for SAA 1.3 cannot exist in the OS
  164. Protected Domain at rings 1, 2, or 3.
  165.  
  166.     b. Load the protocol stacks that will be required by Communication
  167. Executive prior to loading COMMEXEC.NLM.  If you do load COMMEXEC.NLM, and
  168. it has been configured to require other protocol stacks (SPXS, Appletalk,
  169. or TCP/IP), and the protocol stack has not been loaded, the following error
  170. message would display:
  171.  
  172.         "CE: unable to build stream driver <XXX>..."
  173.  
  174.     c. The CSSTATUS statement should not appear immediately after the LOAD
  175. COMMEXEC statement in an AUTOEXEC.NCF file.  You may either issue the
  176. CSSTATUS statement manually, or insert another statement between the
  177. CSSTATUS and the LOAD COMMEXEC.
  178.  
  179.     d. STREAMS NLM - The 4.0X installation for NWSAA copies a new STREAMS.NLM
  180. module to the server.  If this module does not get loaded into memory, you
  181. may experience an ABEND while performing a DOWN operation.  To avoid this
  182. problem, make certain that you down the server after installation to ensure
  183. that the new STREAMS.NLM gets loaded.
  184.  
  185.     e. The Eicon driver takes up to 15 seconds to load and initialize.  This
  186. means that it may be necessary to insert a command or procedure in
  187. AUTOEXEC.NCF to delay the execution of subsequent CSLOAD commands for
  188. profiles that use the EICON driver in AUTOEXEC.NCF.  The Eicon driver must
  189. be loaded after loading the Communication Executive.  The public domain NLM
  190. called DELAY.NLM is one example of a method you could use to delay
  191. execution of the CSLOAD command.
  192.  
  193.         Another alternative is to issue the CSLOAD command manually from
  194. the NetWare console.
  195.  
  196.     f. On any Micro Channel server that uses the IBM MPA SDLC board, add the
  197. following command to AUTOEXEC.NCF:
  198.  
  199.         SET AUTOREGISTER MEMORY ABOVE 16MB = OFF
  200.  
  201.         The IBM MPA SDLC board will not work properly on a machine that
  202. addresses memory above 16MB.
  203.  
  204.     g. The LOAD command for EtherNet LAN drivers that are to be bound to IPX
  205. must include the following parameter (as shown in the sample AUTOEXEC.NCF
  206. above):
  207.  
  208.             FRAME=ETHERNET_802.3
  209.  
  210.         This FRAME= statement is necessary to match the workstation
  211. configuration (as well as file server configurations).  The previous
  212. default was ETHERNET_802.3. The new default is ETHERNET_802.2.
  213.  
  214.         If your system uses the PU concentrator feature with WEEAS.EXE, IPX
  215. is bound to both ETHERNET_802.2 and ETHERNET_802.3.
  216.  
  217.     h. Make sure you have the LSLENH and SPXFIX2 load statements before
  218. loading any LAN adapters.
  219.  
  220.   4. Binding and Unbinding a Transport Protocol
  221.  
  222.      To bind a transport protocol manually, issue the following command at
  223. the NetWare console:
  224.  
  225.         CSBIND [spx|appletalk|tcp-ip]
  226.  
  227.      To unbind a transport protocol manually, issue the following command
  228. at the NetWare console:
  229.  
  230.         CSUNBIND [spx|appletalk|tcp-ip]
  231.  
  232.      Under NetWare 4.0, CSUNBIND is the only method of unloading a
  233. transport protocol while workstations are connected to NetWare for SAA.
  234.     If you need to remove Directory Services from the server that has NetWare
  235. for SAA installed on it, first backup the profiles (using SAACOPY), then
  236. remove NWSAA and COMMEXEC from the server.  After reinstalling the
  237. Directory Services, you should reinstall the COMMEXEC and NWSAA.  Then,
  238. copy the profiles back to the server, using SAACOPY.
  239.  
  240.   5. NetWare for SAA 1.3 supports only two host connections.  You may only
  241. install two licensed copies of NetWare for SAA on a single server.  If you
  242. try to install a third copy on the server, one of the following things will
  243. happen:
  244.     a. If the third copy is a newer version number than the copies already
  245. installed, the server will be updated with the new software.
  246.  
  247.     b. If the third copy is the same, or a lesser version, the installation
  248. will fail.
  249.  
  250.         To increase the number of sessions, first remove at least one of
  251. the copies of NetWare for SAA from the server and reinstall with the copy
  252. containing the number of licenses you want.  Note that any profile
  253. information will be lost unless you backup the profile using SAACOPY to
  254. copy it to another server.
  255.  
  256.   6. Installing NWSAA while CSL.NLM is loaded will cause problems. 
  257. Problems have been encountered if NWSAA is installed and you are
  258. implementing a QLLC connection to a host with the Newport X.25 driver, or
  259. SNALinks has been installed while the CSL.NLM is loaded.  The symptom is
  260. that the Newport X.25 driver will not be able to read its configuration
  261. database.  We have observed that Netware 4.01 may generate a spurious
  262. server-down events when objects are created in the directory services. 
  263. These events may cause the CSL.NLM to enter a state where it will no longer
  264. allow drivers to get their configuration and load.
  265.  
  266.      To avoid this problem, make certain that CSL is unloaded and reloaded
  267. again after performing any operations such as loading the Newport X.25
  268. driver, running CSCON to configure profiles, groups or ACL's.
  269.  
  270.      There is a patch for Directory Services, that will eliminate the
  271. problem described above.  The name of the patch is DSPAT.ZIP and it is on
  272. NETWIRE.  This directory services patch corrects several other problems
  273. related to directory services.  If you are using the CSL.NLM you should
  274. obtain this directory services patch and follow the DSPAT.TXT file to
  275. install the patch.
  276.  
  277.   7. NetWare for SAA 1.3 supports only two host connections.  You may only
  278. install two licensed copies of NetWare for SAA on a single server.  If you
  279. try to install a third copy on the server, one of the following things will
  280. happen:
  281.     a. If the third copy is a newer version number than the copies already
  282. installed, the server will be updated with the new software.
  283.  
  284.     b. If the third copy is the same, or a lesser version, the installation
  285. will fail.
  286.  
  287.         To increase the number of sessions, first remove at least one of
  288. the copies of NetWare for SAA from the server and reinstall with the copy
  289. containing the number of licenses you want.  Note that any profile
  290. information will be lost unless you backup the profile using SAACOPY to
  291. copy it to another server.
  292.  
  293.   8. Novell recommends the use of ODI drivers, for both the host connection
  294. and the LAN connection.
  295.  
  296.   9. Token Ring Drivers Node Address message
  297.  
  298.      With the ODI Token Ring drivers, specifying a node address in the LOAD
  299. statement causes the following message to appear on the system console at
  300. load time:
  301.  
  302.         "WARNING: Token-NU-127:  The local bit in the node address override was
  303. set"
  304.  
  305.      This message is informational, to let you know that a locally
  306. administered node address has been specified.
  307.  
  308.   10. Novell recommends the use of the latest X.25 drivers for your X.25
  309. adapter.  Both Novell and Newport Systems have new drivers that support
  310. NetWare for SAA 1.3.  At the present time, only the Newport driver is
  311. available for operation in a NetWare 4.0 environment.
  312.  
  313.   11. Disaster Recovery Tips
  314.  
  315.       Once you have installed the PTFs, we recommend that you backup
  316. CSMASTER.DBA to a diskette.  If CSMASTER.DBA should become corrupted
  317. because of a server crash, you may then copy CSMASTER.DBA to the SYSTEM
  318. subdirectory and restart the system.  The following symptoms may indicate
  319. corruption of  CSMASTER.DBA:
  320.  
  321.     * Unable to load a service profile
  322.     * Unable to attach to a Communication Server through CSCON
  323.     * Receive an error message after loading the Communication Executive
  324.     * Cannot access the audit trail or event log
  325.  
  326.   12. Mainframe and AS/400 Concurrent Access
  327.  
  328.       To access a 3270 session and a PC Support session concurrently from
  329. the same workstation, use RUMBA/400 offered by WallData, Inc. and IBM
  330. Corp., or use ATTACHMATE.  At the present time, NetWare 3270 LAN
  331. Workstation for DOS does not support this configuration.
  332.  
  333.   13. QLLC Support
  334.  
  335.       To support PVC links on a VM/CMS 9370, the host must be configured to
  336. retry QSM(SNRM) and QXID(XID) indefinitely.
  337.  
  338.   14. OS/2 Software for NWSAA Access Support
  339.  
  340.       This release has modules needed for OS/2 NWSAA Access Support.  These
  341. files are copied to the volume:SYSTEM\NWSAA subdirectory during
  342. installation.
  343.       WEEAS.EXE
  344.       WCM.DLL
  345.       WEEAS.ICO
  346.       WEEAS.HLP
  347.  
  348.       To install OS/2 NetWare for SAA Access Support software, create a
  349. subdirectory on the OS/2 machine, and copy these files to it.  Then create
  350. a new program item with the Presentation Manager.  Use WEEAS.EXE as the
  351. program filename when creating the new program item.  After loading this
  352. program, use Connect, Disconnect, etc. to log in, disconnect, etc.
  353.  
  354.   15. PU 2.1  and PU 2.0 Profile Information
  355. NWSAA 1.3 will support any combination of PU 2.0 or PU 2.1 profiles.  The
  356. maximum amount of profiles is two per server.  You can have a server
  357. configured for two PU 2.0 profiles, or two PU 2.1 profiles, or one PU 2.1
  358. and one PU 2.0 profile.
  359.  
  360.       The variation from this is when PCSUPPORT is one of the PU 2.1
  361. profiles; when this is the case you cannot have the other profile be
  362. another PCSUPPORT PU 2.1.  You can have a SNALINKS PU 2.1 profile and a
  363. PCSUPPORT PU2.1 profile on the same server.
  364.  
  365.   16. When upgrading from NetWare for SAA v1.2 to 1.3, the upgrade
  366. automatically creates a default adapter name.  Execute CSCON and change the
  367. Logical Adapter Name entry so that it matches the NAME = parameter in the
  368. AUTOEXEC.NCF.
  369.  
  370.   17. If you are using a NE2-32 LAN adapter, the correct Logical Adapter
  371. Name is NE2_32.  Modify the Logical Adapter Name entry in CSCON and NAME =
  372. parameter in the AUTOEXEC.NCF accordingly.
  373.  
  374.   18. NetWare Update Considerations
  375.  
  376.       If NetWare for SAA 1.3 is installed on a NetWare 3.11 server that is
  377. later upgraded to NetWare 4.0, the first invocation of COMMEXEC.NLM (in the
  378. upgraded NetWare 4.0 system) will automatically perform the necessary
  379. conversion to enable COMMEXEC.NLM to run in the NetWare 4.0 environment.
  380.  
  381.       If you plan to upgrade more than one NetWare for SAA server from
  382. NetWare 3.11 to NetWare 4.0 to the same Organizational Unit (context) in a
  383. NetWare 4.0 directory tree, after each upgrade issue the following command
  384. on the server console to upgrade each NetWare for SAA server:
  385.  
  386.         LOAD CSUPDT40
  387.  
  388.      NOTE: Only users defined in the same organizational unit in which
  389. NetWare for SAA has been installed can access NetWare for SAA services. 
  390. Login control and ACL checking are done in the same context in which
  391. NetWare for SAA is installed.
  392.  
  393. OTHER NOTES
  394.  
  395.   1. If NetWare for SAA is unloaded (with CSUNLOAD) and then reloaded
  396. immediately (with CSLOAD) while a large number (i.e., approximately 100) of
  397. downstream PUs are connected to it, NetWare for SAA may abend with the
  398. following error:
  399.  
  400.         "FSM_XID3_NEG_PROTO."
  401.  
  402.       This error occurs only if the downstream PUs are also running NetWare
  403. for SAA on a server.
  404.  
  405.       To avoid this problem, wait for about two minutes between unloading
  406. and reloading NetWare for SAA.
  407.  
  408.   2. Do not unload DLM while NetWare for SAA is loaded.
  409.  
  410.   3. Unexplained host disconnections have occurred when using the NetWare
  411. for SAA Synchronous Adapter with a Zilog chip at board location U4. 
  412. Adapters with an AMD chip at location U4 do not experience this problem.
  413.  
  414.   4. The following message at the console lets you know that the system had
  415. to allocate additional ECBs for the SDLC adapter:
  416.  
  417.         "R3SDLC: Please increase minimum packet receive buffers in STARTUP.NCF 
  418. file and increase maximum packet receive buffers in AUTOEXEC.NCF."
  419.  
  420.      The message occurs more frequently when the minimum packet receive
  421. buffers parameter has been set to less than the recommended number of 500. 
  422. Operation will continue normally if memory is available for this ECB to be
  423. allocated.
  424.  
  425.   5. On a PS/2 Model 95 server, running two NetWare for SAA Synchronous
  426. Adapters causes the following messages to be displayed more than once at
  427. the NetWare console: "Spurious Hardware Interrupt 3 Detected" and "Spurious
  428. Hardware Interrupt 4 Detected."  The following NetWare command will stop
  429. these messages from being displayed:
  430.  
  431.         SET DISPLAY SPURIOUS INTERRUPT ALERTS = OFF
  432.  
  433.   6. Do not unload DLM while NetWare for SAA is loaded.
  434.  
  435.   7. If NetWare for SAA is unloaded (with CSUNLOAD) and then reloaded
  436. immediately (with CSLOAD) while a large number (i.e., approximately 100) of
  437. downstream PUs are connected to it, NetWare for SAA may abend with the
  438. following error:
  439.          FSM_XID3_NEG_PROTO.
  440.  
  441. This error occurs only if the downstream PUs are also running NetWare for
  442. SAA on a server.
  443.  
  444. To avoid this problem, wait for about two minutes between unloading and
  445. reloading NetWare for SAA.
  446.  
  447.   8. When using the Newport Driver and X.25 (QLLC), occasionally, calls
  448. will not get made from the X.25 driver.
  449.   The workaround for this is:
  450.        >CSUNLOAD <profile>
  451.        >UNLOAD <newport driver>
  452.        >LOAD <newport driver>
  453.        >CSLOAD <profile>
  454.  
  455.   9. Running SDLC on servers faster than 50 Mhz can cause problems when
  456. loading the R3SDLC.LAN driver.  This will cause the following message to
  457. display when the SAA profile is loaded:
  458.  
  459.           DLCI ERROR: Adapter requested by NWSAA was not found.
  460.  
  461.      To recover, reload R3SDLC.LAN before you load the SAA profile.
  462.  
  463.   10. Unexplained host disconnections have occurred when using the NetWare
  464. for SAA Synchronous Adapter with a Zilog chip at board location U4. 
  465. Adapters with an AMD chip at location U4 do not experience this problem.
  466.  
  467. 11.  The following message at the console lets you know that the system had
  468. to allocate additional ECBs for the SDLC adapter:
  469.  
  470.         R3SDLC: Please increase minimum packet receive buffers in STARTUP.NCF 
  471. file and increase maximum packet receive buffers in AUTOEXEC.NCF.
  472.  
  473.       The message occurs more frequently when the minimum packet receive
  474. buffers parameter has been set to less than the recommended number of 500. 
  475. Operation will continue normally if memory is available for this ECB to be
  476. allocated.
  477.  
  478.   12. On a PS/2 Model 95 server, running two NetWare for SAA Synchronous
  479. Adapters causes the following messages to be displayed more than once at
  480. the NetWare console: 'Spurious Hardware Interrupt 3 Detected' and 'Spurious
  481. Hardware Interrupt 4 Detected.'  The following NetWare command will stop
  482. these messages from being displayed:
  483.  
  484.          SET DISPLAY SPURIOUS INTERRUPT ALERTS = OFF
  485.  
  486.   13. Using the RUNCMD Query Server
  487.  
  488.       Using the RUNCMD 'Query Server' without any attributes will return
  489. the maximum number of connections supported as the number of NetWare OS
  490. licenses (max. number of NCP users) plus 100.  The additional 100
  491. connections reflect the capability of NetWare modules to use these
  492. connections.  For an accurate number, subtract 100 from the value
  493. returned.
  494.  
  495.      The response from 'Query file or directory' may be incomplete if the
  496. 'Maximum Frame Size to Transmit Inbound' defined in the host connection of
  497. the service profile used to send RUNCMDs is less than 521 (that is, 256). 
  498. The ideal size is 1033, but 521 does work.
  499.  
  500.      The user name in RUNCMD does not support a group name.
  501.  
  502.