home *** CD-ROM | disk | FTP | other *** search
/ Network Support Encyclopedia 96-1 / novell-nsepro-1996-1-cd2.iso / download / netware / nwc003.exe / NWC003.TXT < prev    next >
Text File  |  1995-05-02  |  7KB  |  159 lines

  1. NOVELL TECHNICAL INFORMATION DOCUMENT
  2.  
  3. TITLE:  NWC003.EXE; NetWare Connect Maintenance
  4. README FOR:  NWC003.EXE
  5.  
  6. NOVELL PRODUCTS and VERSIONS:
  7. NetWare Connect 1.0
  8.  
  9. ABSTRACT:
  10.  
  11. NWC003 is the latest maintenance patch for NetWare Connect 1.0.34 and 1.0.41.  It contains several fixes and enhanced features.
  12.  
  13.  
  14. -----------------------------------------------------------------
  15. DISCLAIMER
  16. THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL.  NOVELL
  17. MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION.  HOWEVER, THE
  18. INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION ONLY.  NOVELL
  19. MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS INFORMATION.
  20. -----------------------------------------------------------------
  21.  
  22.  
  23. SYMPTOM:
  24.  
  25. 1. Spurious "Network Error" messages where received when NCS was used with PCAnywhere.
  26.  
  27. 2. File transfer errors, while using Procomm Plus, with the ZMODEM file transfer protocol.
  28.  
  29. 3. "Primary Interrupt Controller" error messages on the server, when used with some non standard serial ports.
  30.  
  31. 4. Use of the remote license feature, could add the port licenses to the wrong Netware Connect 1.0 machine.
  32.  
  33. 5. Some applications could not find the NCS ports while using Netware Connect's INT14 redirector.
  34.  
  35. 6. The "Lease Line" option within Dialcon did not properly initialize.
  36.  
  37. 7. If Netware Connect was loaded in the same server as Novell's MultiProtocol Router v2.11, the use of the ALT ESC keys to switch console screens resulted in a poorly formatted screen.
  38.  
  39. 8. REACHOUT 4.02 users could not see NCS ports after rebooting a NCS workstation set up for host mode.
  40.  
  41. 9. Intermittent failure to connect via X.25.
  42.  
  43. Enhanced Features:
  44. 1. RNS.LAN has been modified to increase the performance for remote node users by increasing the number of buffers used in the server.
  45. (Formerly in the patch NWCRNS.EXE) 
  46.  
  47. 2. VNRN.386 has been changed so that a Windows user with a serial mouse will no longer have to put the modem on COM1, and the mouse on COM2.  Now, the mouse can be on either COM port.
  48.  
  49. 3. NWCNCF.NLM and NWCNCFRM.NLM have been modified, so that all printable characters, can now be used in AppleTalk "ZONE" names.
  50.  
  51. 4. NWCTRAP.MIB and NWCTRAP.HLP have been changed so that the error messages referenced by Netware Global Messaging users are more specific about the exact error occurring.
  52.  
  53. 5. RNS.LAN changed to increased speed for multiple connections through Remote Node.
  54.  
  55. SOLUTION: 
  56.  
  57. Apply NWC003
  58.  
  59. Self-Extracting File Name: nwc003.exe
  60.  
  61. Files Included     Size     Date      Time
  62.  
  63. ..\
  64.       NWC003.TXT     (This file)
  65.          AIO.NLM           83033         7-28-94     10:24:50 am
  66.      AIOCOMX.NLM           17500         1-13-95     11:36:58 am
  67.       AIOPAD.NLM           39494         1-13-95     10:41:58 am
  68.      CONNECT.001             664          5-1-95      1:25:08 pm
  69.      CONNECT.RMV            3541         12-2-94     12:14:22 am
  70.     CSINSTAL.HLP            2336          3-9-93      6:44:30 pm
  71.      DIALCON.EXE          203023         1-20-95     12:24:26 pm
  72.         NASI.EXE           33286         1-20-95     12:21:08 pm
  73.         NASU.NLM           75420         10-3-94      4:11:18 pm
  74.          NCS.NLM           67708          2-9-95      2:39:06 pm
  75.       NINT14.COM            2948         10-3-94     10:01:56 am
  76.       NWCLIC.NLM           14082        11-21-94      2:19:32 pm
  77.       NWCNCF.NLM           41008          9-7-94      5:15:10 pm
  78.     NWCNCFRM.NLM           63076          9-7-94      5:15:56 pm
  79.      NWCTRAP.HLP           20374        10-10-94     12:24:42 pm
  80.      NWCTRAP.MIB           23769         11-9-94      6:06:18 pm
  81.     PINSTALL.NLM           87440        11-16-94      6:09:34 pm
  82.      PRODUCT.DEF             701         2-21-95     11:09:50 am
  83.          RNS.LAN           23132        12-15-94     10:48:50 am
  84.         VNRN.386           14587         1-31-95      3:48:52 pm
  85. ..\NW4X\
  86.          AIO.NLM           90350         7-28-94     10:24:58 am
  87.         NASU.NLM           89721        12-19-94      4:12:24 pm
  88.     NWCNCFRM.NLM           76359          9-7-94      5:16:34 pm
  89.  
  90.  
  91. Installation Instructions:
  92.  
  93. 1. Make certain the existing PRODUCTS.DAT and PRODUCT.DEF files are flagged "Read Write".
  94. 2. Load INSTALL at the Netware Connect server.
  95. 3. Select "Product Options".
  96. 4. If it shows rev 1.0.33 or lower, you MUST FIRST install NWC001 and NWC002.  AFTER you have done that, continue with the installation of NWC003.
  97. 5. If it shows rev 1.0.34 or 1.0.41, install NWC003 only.  You do not need to install NWC001 and NWC002.
  98. 6. XCOPY (with the /S parameter) to a high density floppy, the files in NWC003.  NOTE: the /s parameter is required to duplicate the directory structure created of NWC003.
  99. 7. From the console of the Netware Connect server, type <NWCSTOP>.
  100. 8. Unload all AIO drivers i.e.; AIOCOMX, AIODGXI, AIOWNIM etc.
  101. 9. Unload AIO.NLM
  102. 10. Load INSTALL.
  103. 11. Select "Product Options".
  104. 12. Press <INSERT>
  105. 13. Place the floppy disk from step #5 into the drive of the Netware Connect server and press <ENTER>.
  106. 14. The program will ask you if you wish to "Install on This Server". Press  <ENTER>.
  107. If the program  gives you an error message here, you need to install NWC001 AND NWC002 first.  Then install NWC003.
  108. The message is listed as a "Note" at the end of this document.
  109. 15. If you did not receive the error message, the files will be copied automatically to the fileserver.
  110. 16. A screen should appear which shows rev 1.0.42.  If it does NWC003 has been successfully installed.
  111. 17. Exit the Netware INSTALL menu.
  112. 18. Reload AIO.NLM and all AIO port drivers.
  113. 19. At the console prompt, type <NWCSTART>
  114. 20. Copy the new versions of the following files over the existing copies on all client workstations.
  115. ----- NASI.EXE
  116. ----- VRN.386
  117. ----- NINT14.COM
  118. ----- DIALCON.EXE
  119.  
  120. Solution Specifics:
  121. Symptoms #1. & #2. NASI.EXE changed.
  122.  
  123. Symptom #3. AIOCOMX.NLM changed.
  124.  
  125. Symptom #4. NWCLIC.NLM changed.
  126.  
  127. Symptom #5. NINT14.COM changed.
  128.  
  129. Symptom #6. DIALCON.EXE changed.
  130.  
  131. Symptom #7. AIO.NLM changed.
  132.  
  133. Symptom #8. NCS.NLM changed.
  134.  
  135. Symptom #9. AIOPAD.NLM to increase buffer parameters.
  136.  
  137.  
  138. NOTE: The Error Message mentioned in #13 above is:
  139.  
  140.  
  141. DESCRIPTION
  142. The product you are trying to install, Netware Connect, cannot be installed because it is incompatible with the product CONNECT which is already installed on this server.
  143.  
  144. (On a Red Screen)
  145. SEVERITY-
  146.       FATAL - Program execution cannot continue normally.
  147.  
  148.                    <Press ESCAPE to Continue>
  149.  
  150. This message really means - You should install NWC001 and NWC002 before installing NWC003.
  151.  
  152.  
  153. -----------------------------------------------------------------
  154. Any trademarks referenced in this document are the property of their
  155. respective owners.  Consult your product manuals for complete trademark
  156. information.
  157. -----------------------------------------------------------------
  158.  