home *** CD-ROM | disk | FTP | other *** search
/ Handbook of Infosec Terms 2.0 / Handbook_of_Infosec_Terms_Version_2.0_ISSO.iso / text / rfcs / rfc0804.txt < prev    next >
Text File  |  1996-05-07  |  17KB  |  142 lines

  1.  
  2.  
  3.  
  4.  
  5. RFC 804 
  6.  
  7.                 CCITT Draft Recommendation T.4 
  8.  
  9.    As Defined In: CCITT STUDY GROUP XIV, CONTRIBUTION No.25-E 
  10.  
  11. SOURCE: DRAFTING GROUP ON DRAFT RECOMMENDATION T.4 TITLE: DRAFT RECOMMENDATION T.4 - STANDARDIZATION OF GROUP 3     FACSIMILE   APPARATUS   FOR  DOCUMENT  TRANSMISSION  (as     amended and agreed by Working Party XIV/2) 
  12.  
  13. Draft Recommendation T.4 
  14.  
  15. STANDARDIZATION OF GROUP 3 FACSIMILE APPARATUS FOR  DOCUMENT TRANSMISSION 
  16.  
  17. The CCITT, considering 
  18.  
  19. a.  that Recommendation T.2 refers to Group 1 type apparatus     for  ISO  A4 document transmission over a telephone-type     circuit in approximately six minutes; b.  that Recommendation T.3 refers to Group 2 type apparatus     for  ISO  A4 document transmission over a telephone-type     circuit in approximately three minutes: c.  that there is a  demand  for  Group  3  apparatus  which     enables  an  ISO  A4  document  to be transmitted over a     telephone-type circuit in approximately one minute; d.  that for a large number of applications black and  white     reproduction is sufficient; e.  that  such   a   service   may   be   requested   either     alternatively   with  telephone  conversation,  or  when     either or both stations are not attended; in both cases,     the facsimile operation will follow Recommendation T.30, 
  20.  
  21. (unanimously) declares  the  view  that  Group  3  facsimile apparatus  for use on the general switched telephone network and international leased circuits  should  be  designed  and operated according to the following standards: 
  22.  
  23.  1.  Scanning track 
  24.  
  25.      The  message  area  should  be  scanned  in  the   same direction  in  the  transmitter  and  receiver.  Viewing the message area in a vertical  plane,  the  scanning  direction should  be from left to right and subsequent scans should be adjacent and below the previous scan. 
  26.  
  27.  2.  Dimensions of apparatus 
  28.  CCITT Draft Recommendation T.4                      PAGE   2 
  29.  
  30.  
  31.  
  32.      The following dimensions should be used: 
  33.  
  34. a.  A normal definition  standard  and  an  optional  higher     definition standard of 3.85 and 7.7 line/mm respectively     in vertical direction; b.  1728 black and white picture elements along the  scanned     line; c.  A scanning line length of 215 mm.  Other  scanning  line     lengths  may  be  employed  in  which  case the scanning     density  should  be  changed  to  maintain  the  correct     picture proportions; d.  Input documents up to a minimum of ISO A4 size should be     accepted. 
  35.  
  36. 3.  Transmission time per scanning line 
  37.  
  38.      A total scanning line is defined as  the  sum  of  DATA bits  plus  any  required  FILL bits plus the EOL bits.  The minimum transmission times of the total scanning line should conform to the following: 
  39.  
  40. a.  20 milliseconds recommended standard  with  an  optional     fall-back to the 40 milliseconds option; b.  10  milliseconds  recognized  option  with  a  mandatory     fall-back to the 20 milliseconds standard; c.  5  milliseconds  recognized  option  with  a   mandatory     fall-back  to  the  10  milliseconds  option  and the 20     milliseconds standard; d.  40 milliseconds recognized option. 
  41.  
  42.      The  identification  and   choice   of   this   minimum transmission time is to be made in the pre-message (Phase B) portion  of  the  T.30  control  procedure.    The   maximum transmission  time of any total scanning line should be less than 5 seconds. 
  43.  
  44. 4.  Coding scheme 
  45.  
  46.      The  one-dimensional   run   length   encoding   scheme recommended for Group 3 apparatus is as follows: 
  47.  
  48. a.  DATA     A line of data is  composed  of  a  series  of  variable     length  code  words.   Each  code  word represents a run     length of either all white or all black.  White runs and     black  runs alternate.  A total of 1728 picture elements     represent one horizontal scanning line of  the  document     of  standard  A4  size.   In  order  to  insure that the     receiver maintains color synchronization, all DATA lines     will  begin  with  a white run length code word.  If the     actual scanning line begins with a black  run,  a  white     run  length  of  zero  will be sent.  Black or white run     lengths, up to a maximum length  of  one  scanning  line 
  49.  CCITT Draft Recommendation T.4                      PAGE   3 
  50.  
  51.  
  52.  
  53.     (1728  picture elements or pels) are defined by the code     words in Tables 1 and 2.  The  code  words  are  of  two     types:  Terminating  Code  words and Make Up Code words.     Each run length is represented by either one Terminating     Code  word  or  one  Make  Up  Code  word  followed by a     Terminating Code word. 
  54.  
  55.     Run lengths in the range of 0 to  63  pels  are  encoded     with their appropriate Terminating Code word.  Note that     there is a different list of code words  for  black  and     white run lengths. 
  56.  
  57.     Run lengths in the range of 64 to 1728 pels are  encoded     first  by  the  Make  Up  Code word representing the run     length which is equal to or shorter than that  required.     This  is  then  followed  by  the  Terminating Code word     representing the difference  between  the  required  run     length  and  the  run  length represented by the Make Up     Code. 
  58.  
  59. b.  END OF LINE (EOL) 
  60.  
  61.     This code word follows each  line  of  DATA.   It  is  a     unique  code word that can never be found within a valid     line of  DATA;  therefore,  resynchronization  after  an     error burst is possible. 
  62.  
  63.     In addition, this signal will occur prior to  the  first     DATA line of a page. 
  64.  
  65.                     Format: 000000000001 
  66.  
  67. c.  FILL 
  68.  
  69.     A  pause  may  be  placed  in  the   message   flow   by     transmitting  FILL.  FILL may be inserted between a line     of DATA and an EOL, but never within  a  line  of  DATA.     Fill  must  be  added  to insure that each line of DATA,     FILL, and EOL exceeds the minimum transmission time of a     total   scanning  line  established  in  the  premessage     control procedure.  The maximum length for a single line     of  FILL  is  5  seconds,  after  which the receiver may     disconnect. 
  70.  
  71.         Format: variable length string of 0's.       
  72.  
  73. d.  RETURN TO CONTROL (RTC) 
  74.  
  75.     The end of  a  document  transmission  is  indicated  by     sending   six  consecutive  EOL's.   Following  the  RTC     signal, the  transmitter  will  send  the  post  message     commands in the standard T.30 blocked format at the data     rate. 
  76.  CCITT Draft Recommendation T.4                      PAGE   4 
  77.  
  78.  
  79.  
  80.      Format: 000000000001 ... ... ... ... 000000000001                      (total of 6 times) 
  81.  CCITT Draft Recommendation T.4                      PAGE   5 
  82.  
  83.  
  84.  
  85.          Table 1a. Terminating White Codes          Code            Lng     Run          ---------------------------          00110101        8       0          000111          6       1          0111            4       2          1000            4       3          1011            4       4          1100            4       5          1110            4       6          1111            4       7          10011           5       8          10100           5       9          00111           5       10          01000           5       11          001000          6       12          000011          6       13          110100          6       14          110101          6       15          101010          6       16          101011          6       17          0100111         7       18          0001100         7       19          0001000         7       20          0010111         7       21          0000011         7       22          0000100         7       23          0101000         7       24          0101011         7       25          0010011         7       26          0100100         7       27          0011000         7       28          00000010        8       29          00000011        8       30          00011010        8       31          00011011        8       32          00010010        8       33          00010011        8       34          00010100        8       35          00010101        8       36          00010110        8       37          00010111        8       38          00101000        8       39          00101001        8       40          00101010        8       41          00101011        8       42          00101100        8       43          00101101        8       44          00000100        8       45          00000101        8       46          00001010        8       47          00001011        8       48          01010010        8       49 
  86.  CCITT Draft Recommendation T.4                      PAGE   6 
  87.  
  88.  
  89.  
  90.          01010011        8       50          01010100        8       51          01010101        8       52          00100100        8       53          00100101        8       54          01011000        8       55          01011001        8       56          01011010        8       57          01011011        8       58          01001010        8       59          01001011        8       60          00110010        8       61          00110011        8       62          00110100        8       63 
  91.  CCITT Draft Recommendation T.4                      PAGE   7 
  92.  
  93.  
  94.  
  95.          Table 1b. Make Up White Codes          Code            Lng     Run          ---------------------------          11011           5       64          10010           5       128          010111          6       192          0110111         7       256          00110110        8       320          00110111        8       384          01100100        8       448          01100101        8       512          01101000        8       576          01100111        8       640          011001100       9       704          011001101       9       768          011010010       9       832          011010011       9       896          011010100       9       960          011010101       9       1024          011010110       9       1088          011010111       9       1152          011011000       9       1216          011011001       9       1280          011011010       9       1344          011011011       9       1408          010011000       9       1472          010011001       9       1536          010011010       9       1600          011000          6       1664          010011011       9       1728 
  96.  CCITT Draft Recommendation T.4                      PAGE   8 
  97.  
  98.  
  99.  
  100.          Table 2a. Terminating Black Codes          Code            Lng     Run          ---------------------------          0000110111      10      0          010             3       1          11              2       2          10              2       3          011             3       4          0011            4       5          0010            4       6          00011           5       7          000101          6       8          000100          6       9          0000100         7       10          0000101         7       11          0000111         7       12          00000100        8       13          00000111        8       14          000011000       9       15          0000010111      10      16          0000011000      10      17          0000001000      10      18          00001100111     11      19          00001101000     11      20          00001101100     11      21          00000110111     11      22          00000101000     11      23          00000010111     11      24          00000011000     11      25          000011001010    12      26          000011001011    12      27          000011001100    12      28          000011001101    12      29          000001101000    12      30          000001101001    12      31          000001101010    12      32          000001101011    12      33          000011010010    12      34          000011010011    12      35          000011010100    12      36          000011010101    12      37          000011010110    12      38          000011010111    12      39          000001101100    12      40          000001101101    12      41          000011011010    12      42          000011011011    12      43          000001010100    12      44          000001010101    12      45          000001010110    12      46          000001010111    12      47          000001100100    12      48          000001100101    12      49 
  101.  CCITT Draft Recommendation T.4                      PAGE   9 
  102.  
  103.  
  104.  
  105.          000001010010    12      50          000001010011    12      51          000000100100    12      52          000000110111    12      53          000000111000    12      54          000000100111    12      55          000000101000    12      56          000001011000    12      57          000001011001    12      58          000000101011    12      59          000000101100    12      60          000001011010    12      61          000001100110    12      62          000001100111    12      63 
  106.  CCITT Draft Recommendation T.4                      PAGE  10 
  107.  
  108.  
  109.  
  110.          Table 2b. Make Up Black Codes          Code            Lng     Run          ---------------------------          0000001111      10      64          000011001000    12      128          000011001001    12      192          000001011011    12      256          000000110011    12      320          000000110100    12      384          000000110101    12      448          0000001101100   13      512          0000001101101   13      576          0000001001010   13      640          0000001001011   13      704          0000001001100   13      768          0000001001101   13      832          0000001110010   13      896          0000001110011   13      960          0000001110100   13      1024          0000001110101   13      1088          0000001110110   13      1152          0000001110111   13      1216          0000001010010   13      1280          0000001010011   13      1344          0000001010100   13      1408          0000001010101   13      1472          0000001011010   13      1536          0000001011011   13      1600          0000001100100   13      1664          0000001100101   13      1728 
  111.  CCITT Draft Recommendation T.4                      PAGE  11 
  112.  
  113.  
  114.  
  115. Note: It is recognized that machines exist which accommodate larger   paper   widths   whilst  maintaining  the  standard horizontal resolution.  This option has been provided for by the addition of the Make Up Code Set defined as follows: 
  116.  
  117.                      Table 3. Extended Make Up Codes (Black and White)          Code            Lng     Run          ---------------------------          00000001000     11      1792          00000001100     11      1856          00000001101     11      1920          000000010010    12      1984          000000010011    12      2048          000000010100    12      2112          000000010101    12      2176          000000010110    12      2240          000000010111    12      2304          000000011100    12      2368          000000011101    12      2432          000000011110    12      2496          000000011111    12      2560 
  118.  
  119.      The identification and choice of  either  the  standard code  table  or the extended code table is to be made in the pre-message  (Phase  B)  portion   of   the   T.30   control procedures. 
  120.  
  121. 4.2 Two dimensional coding scheme 
  122.  
  123.      The one-dimensional coding scheme defined in 4.1 may be extended  as an option to a two-dimensional scheme.  This is the subject of further study. 
  124.  
  125. 5.  Modulation and demodulation method 
  126.  
  127.      It is  provisionally  agreed  that  Group  3  apparatus operating  on  the  general switched telephone network shall utilize the modulation scrambler,  equalization  and  timing signals  defined  in Recommendation V.27ter, specifically in the preamble and 2, 3, 6, 7, 9 and 10. 
  128.  
  129.      The  data  signalling  rates  to  be  used  are   those recommended  in  Recommendation V.27ter, i.e.  4800 and 2400 bit/s. 
  130.  
  131. Note 1: Some administrations pointed out that it  would  not be  possible  to  guarantee the service at a data signalling rate higher than 2400 bit/s. 
  132.  
  133. Note 2: It should be noted  that  there  are  equipments  in service  using,  inter  alia, other modulation methods.  The 
  134.  CCITT Draft Recommendation T.4                      PAGE  12 
  135.  
  136.  
  137.  
  138. arrangement of interworking between equipment conforming  to Recommendation  T.4 and these existing equipments is subject to further study. 
  139.  
  140. Note 3: For higher speed operation, such as may be  possible on  leased circuits, it is provisionally agreed that Group 3 apparatus may utilize the signals specifically defined in 1, 2, 3, 4, 7, 8, 9, 11, and 12 of Recommendation V.29. 
  141.   
  142.