home *** CD-ROM | disk | FTP | other *** search
/ Frostbyte's 1980s DOS Shareware Collection / floppyshareware.zip / floppyshareware / GLEN / ZLAB-18B.ZIP / ZIPLAB.DOC < prev    next >
Text File  |  1991-12-02  |  32KB  |  747 lines

  1.  
  2. ZipLab PLUS Version 1.8b
  3. (C)Copyright 1991 by Jeffrey S. Morley
  4. December 2nd, 1991
  5.  
  6. Archive test program for PCBoard/ProDoor
  7.                   
  8.  
  9.  
  10.  
  11.  
  12.  
  13.  
  14.  
  15.  
  16.  
  17.  
  18.  
  19.  
  20.  
  21.  
  22.  
  23.  
  24.  
  25.  
  26.  
  27.  
  28.  
  29.  
  30.  
  31.  
  32.  
  33.  
  34.  
  35.  
  36.  
  37.  
  38.  
  39.  
  40.  
  41.  
  42.  
  43.  
  44.  
  45.  
  46.  
  47.  
  48.  
  49.  
  50.  
  51.  
  52.  
  53.  
  54.  
  55.  
  56.  
  57.  
  58.  
  59.  
  60.  
  61.                                Table of Contents
  62. ===============================================================================
  63.  
  64. Installation of ZipLab(PTEST.CFG) / Quick Start ...........................  2
  65. Explanation of items in PTEST.CFG / Example ...............................  4
  66. ProDoor Setup .............................................................  5
  67. ZipLab Plus Version History ...............................................  6
  68. Credits ...................................................................  8
  69.  
  70.  
  71.  
  72. What is ZipLab Plus?
  73.  
  74.    ZipLab is an alternative/replacement for the PCBTEST.BAT/PROUTEST.BAT 
  75. files which are run by PCBoard/PRODOOR after a user uploads file(s). In 
  76. the past, we have all run maybe  PKUNZIP -T  on each file, and if there 
  77. were no CRC errors, all was considered well.   There is a lot more we can 
  78. do  to protect ourselves and our users from unwanted files!  ZipLab will 
  79. do the following:
  80.  
  81. * Test for CRC errors in the archive file.
  82. * Test for imbedded archive files and if found, CRC check those too.
  83. * Test for imbedded .TD0 (Teledisk) files and if found, test with TDCHECK.
  84. * Virus SCAN archive member files, using SCAN.EXE from McAffey.
  85. * SCAN inside archive files imbedded inside another archive file.
  86. * Remove all archive comments from the file.
  87. * Replace archive comments with your own. (Optional)
  88. * Delete unwanted BBS ads and/or other unwanted archive members as you define.
  89. * Test .GIF files for validity if you accept that file format (Optional)
  90. * Add the resolution of .GIF files to the description (Optional)
  91. * Reject programs older than a date (year) which you specify.
  92. * Adds most recent archive member date to the description (Optional)
  93. * Allow you to test outside of PCBoard/ProDoor, and use wildcards!
  94. * Run the full range of tests on .ZIP, .LHZ and .ARJ archive formats
  95. * Run SCAN on files which you optionally pass without ZIP testing.
  96. * Calculate the CRC value of the archive, optionally placing this in the 
  97.   file description.
  98. * Optionally replace the description left by the user if FILE_ID.DIZ is
  99.   found in the archive file.
  100. * Will make a notation in the CALLER file for the current node of any 
  101.   files which fail upload testing, including the failure reason.
  102. * Allows your users to run the TEST command in PCBoard to test files, but
  103.   ZipLab will not remove the file if it fails DATE checking.  The file will
  104.   be moved for failure on other tests.  You will be notified via the node's
  105.   CALLER file of archives which fail PCBoard's TEST command.
  106.   
  107.  SPECIAL NOTICE ***** SPECIAL NOTICE **** SPECIAL NOTICE ***** SPECIAL NOTICE
  108.  
  109.  
  110.  
  111.   ** ZIPLAB IS NO LONGER "FREEWARE". REGISTRATION IS REQUIRED FOR ITS USE **
  112.  
  113.     PLEASE SEE THE ENCLOSED REGISTER.DOC FILE FOR REGISTRATION INFORMATION
  114.  
  115.           
  116.  SPECIAL NOTICE ***** SPECIAL NOTICE **** SPECIAL NOTICE ***** SPECIAL NOTICE
  117.  
  118.  
  119.  
  120. Page 1                                                         ZipLab Plus 1.8b
  121.  
  122.  
  123.  
  124. ********* A CHANGE TO YOUR .CFG FILE *IS* REQUIRED FOR THIS RELEASE! *********
  125.  
  126. REQUIRED FOR OPERATION:
  127.  
  128. You must already have the following programs.....
  129.  
  130. PKZIP.EXE   - Phil Katz archive create program (version 1.01 +)
  131. PKUNZIP.EXE - Phil Katz archive extract program (version 1.01 +)
  132. LHA.EXE     - Yoshi's archive program (version 2.13)
  133. ARJ.EXE     - Robert Jung's archive program (version 2.10 +)
  134. TDCHECK.EXE - .TD0 (Teledisk) checker from SyDex (any version)
  135. SCAN.EXE    - McAffey's virus detection program (any version)
  136.  
  137. There are other small utility programs which I have bundled with this 
  138. .ZIP. They may require registration for continued use.  PLEASE SUPPORT 
  139. SHAREWARE AND THE SHAREWARE CONCEPT! REGISTER THESE PROGRAMS IF REQUESTED 
  140. TO DO SO!
  141.  
  142. RECOM.EXE   - Mike Loewen's ZIP file comment remover and date stamper.
  143. GIFTEST.EXE - Dave Navarro's .GIF file tester (part of GIFTSTxx.ZIP)
  144. DELF.COM    - A version of DEL with no "Are you sure?" prompt written by me.
  145.               (No registration required)
  146.  
  147.  
  148. Quick Start ---
  149.  
  150. * NOTE!  Since PCBoard is SHELLING out to run PCBTEST.BAT, there is 
  151.   limited memory available for PTEST.EXE.  If you are running in a 
  152.   multitasking or other memory constrained situation, PTEST may not work! 
  153.   You should have at least 250k free memory when shelled out of PCBoard.  
  154.   If this is a problem, you may want to consider the VAROOM (overlay) 
  155.   version of PCBoard, which runs in considerably less memory than the 
  156.   standard PCB.EXE.
  157.   
  158.   The other option is to run PCBoard with the SET PCB = /SWAP environment 
  159.   variable.  This will cause PCBoard to "swap" its code to the best 
  160.   available storage (EMS, DISK) whenever a SHELL function (external 
  161.   protocol, viewfile, and even DOORS if you have the SHELL column in 
  162.   DOORS.DAT(LST) set to "Y") is called.  This method will cause a slight 
  163.   delay when SHELLING, but will provide the largest amount of available 
  164.   DOS memory for your external code.
  165.   
  166. * Place the PTEST.EXE, SETUP.EXE and DELF.COM files into a directory which 
  167.   is in your DOS PATH.
  168.  
  169. * UnZIP the enclosed supplemental utilities into directories in your DOS 
  170.   PATH. Make note of where you put them, you will need this information 
  171.   later.
  172.  
  173. * Create, or use any existing directory to hold your PTEST configuration 
  174.   files. Change into this directory, and run SETUP.EXE once for each of 
  175.   your nodes. Be sure to give different configuration file names for each 
  176.   node.  I use PTEST1.CFG and PTEST2.CFG. You may keep the particular 
  177.   node's configuration file in the PCBoard ROOT/HOME directory for the 
  178.   node, but this is not required.  
  179.  
  180. Page 2                                                         ZipLab Plus 1.8b
  181.  
  182. * Fill in the following information when prompted by SETUP.EXE:
  183.  
  184.         -  The [drive:\path\]filename.ext of the .CFG file you wish created.
  185.            (This information will not be written to the .CFG file)
  186.         -  The type of modem HANDSHAKE you desire.  This can be 
  187.            0, 1, 2 or 3.  0=none, 1=XON/XOFF, 2=CTS, 3=CTS & XON/XOFF
  188.            (Use 2 or 3 with an error correcting modem...)
  189.         -  The DRIVE:\PATH\NAME of your PCBOARD.DAT file for this node.
  190.         -  The name of your BBS system.  43 characters maximum.
  191.         -  The DRIVE and PATH to the directory where rejects will be
  192.            placed pending manual sysop inspection.
  193.         -  The date (yyyy) which will be the minimum accepted year.  ZIPs
  194.            containing files older than this will be rejected.
  195.         -  A "Y" if you wish to replace the description left by the user
  196.            with the contents of FILE_ID.DIZ (if found in the archive).
  197.            A "N" if you do not wish to make use of this feature.  No changes
  198.            will be made in either case if FILE_ID.DIZ is not found.
  199.         -  A "Y" if you wish the "recent date" notation added to the file
  200.            descriptions.  A "N" if you do not wish this addition.
  201.         -  Information to appear in the description before the "recent date"
  202.            This can be "CRC", "FILES", or "NONE"
  203.            CRC   = The CRC value of the archive
  204.            FILES = The number of files in the archive
  205.            NONE  = Just that... none.
  206.         -  The fully qualified filename of the zip comment to add, or
  207.            type "NONE" if you don't want to add a comment.
  208.         -  The fully qualified filename of a file which you may wish to
  209.            add to the .ZIP, or "NONE" (please!) if you can refrain from
  210.            this practice.
  211.         -  Full DRIVE:\PATH to PKZIP.EXE.
  212.         -  Full DRIVE:\PATH to PKUNZIP.EXE.
  213.         -  Full DRIVE:\PATH to LHA.EXE.
  214.         -  Full DRIVE:\PATH to ARJ.EXE.
  215.         -  Full DRIVE:\PATH to TDCHECK.EXE.
  216.         -  Full DRIVE:\PATH to SCAN.EXE.
  217.         -  Full DRIVE:\PATH to RECOM.EXE.
  218.         -  Full DRIVE:\PATH to GIFTEST.EXE (or NONE if not using)   
  219.         -  Command line PARAMETERS you wish to pass to GIFTEST.EXE
  220.            /B:2 /N:2 /C:C:\VGA\GIFTEST.CFG
  221.            This example would tell GIFTEST.EXE that you are running
  222.            PCBoard, that you are on node 2, and the location of your
  223.            GIFTEST.CFG file.  See the documentation for GIFTEST. 
  224.            Just enter NONE if you do not desire to use parameters.  
  225.         -  A list, each on one line, of any extensions (.EXE, .TXT 
  226.            etc) Which will be passed without normal ZIP testing.  SCAN 
  227.            will still be performed on these files.  Any extensions 
  228.            other than .ZIP which do not appear in this .CFG file will 
  229.            be rejected by the process.  The "." is optional. If .GIF 
  230.            appears in this list, GIFTEST will be used to test the 
  231.            integrity of the .GIF file.
  232.            If you enter a "*" as one of the extentions, then ALL files 
  233.            will be passed through, with non-archived files being 
  234.            SCAN'd only.
  235.         -  A list, each on one line, of files which you wish deleted 
  236.            from .ZIP's before posting.  This could include the famous 
  237.            "READMEOR.DIE", "BBS.AD", or other unwanted advertising. 
  238.            You may also have a file with these names listed one on 
  239.            each line, and pass the name of the file with an "@" before 
  240.            the name.
  241.  
  242.            
  243. Page 3                                                         ZipLab Plus 1.8b
  244.  
  245.  
  246. Sample PTEST.CFG file:
  247.             
  248.             2           
  249.             C:\NODE1\PCBOARD.DAT
  250.             The Interconnect BBS
  251.             M:\HOLD
  252.             1990
  253.             Y
  254.             Y
  255.             FILES
  256.             C:\EXE\COMMENT.CMT
  257.             C:\EXE\FILETO.ADD
  258.             C:\ZIP\PKZIP.EXE
  259.             C:\ZIP\PKUNZIP.EXE
  260.             C:\ZIP\LHA.EXE
  261.             C:\ZIP\ARJ.EXE
  262.             C:\ZIP\TDCHECK.EXE
  263.             C:\DIAGS\SCAN.EXE
  264.             C:\EXE\RECOM.EXE
  265.             C:\EXE\GIFTEST.EXE
  266. NEW!!       /B:2 /N:2 /C:C:\VGA\GIFTEST.CFG
  267.             .ROM
  268.             .GIF
  269.             @BBSADS.LST
  270.  
  271. * Edit your existing PCBTEST.BAT file, and delete the whole thing except 
  272.   for two lines:
  273.   
  274.   Sample PCBTEST.BAT file:
  275.   
  276.   @ECHO OFF
  277.   PTEST %1 C:\ZIPLAB\PTEST1.CFG %2
  278.                                 ^^ NEW!!
  279.  
  280. * That's it... Now when PCBTEST.BAT is run by PCBoard, it will pass 
  281.   command over to PTEST.EXE with the parameter containing the path
  282.   and name of the file to be tested.  PTEST will check out the file,
  283.   placing any rejects in the holding directory you specified in the
  284.   SETUP process above.  
  285.  
  286.   
  287.  
  288.  
  289.  
  290.  
  291.  
  292.  
  293.  
  294.   
  295.   
  296.   
  297.   
  298.   
  299.   
  300.  
  301.   
  302.   
  303. Page 4                                                         ZipLab Plus 1.8b
  304.  
  305.  
  306.  
  307. *  PRODOOR SYSOPS -
  308.    You will need to set up your PROUTEST.BAT file like this:
  309.                 
  310.    echo off
  311.    rem -- process test uploads request - for ProDOOR 3.4
  312.    rem -- %1-logfile, %2-testdir, %3-comport
  313.    
  314.    rem -- test each uploaded file individually
  315.    proecho %3 ~~Testing uploads.  Please wait...~
  316.    
  317.    SET PCBDOOR=PRODOOR
  318.    for %%f in (%2\*.*) do COMMAND /c PTEST %%f drive:\directory\configfilename
  319.    SET PCBDOOR=
  320.    
  321.    :end
  322.             Replace the "drive:\..." stuff with the location and name
  323.             of the PTEST configuration file for this node.
  324.  
  325.              Be sure you have enough ENVIRONMENT space to set up the
  326.              PCBDOOR variable.  If you are using DesqView, you may
  327.              want to set PCBDOOR=xxxxxxx in your AUTOEXEC.BAT to be
  328.              sure enough room is allocated in your DesqView partitions
  329.              for this variable.  The x's will be replaced by PRODOOR
  330.              when PROUTEST.BAT is executed.  I need this variable set
  331.              to "PRODOOR", or PTEST won't know you are running out of
  332.              ProDoor.  You don't want to leave it set to PRODOOR though,
  333.              since this could confuse things for other doors/processes.
  334.              Thus the "SET PCBDOOR=" line.  ZipLab will fully work
  335.              with ProDoor, including display/modification of the file
  336.              descriptions.
  337.   
  338.  
  339.  
  340.  
  341.  
  342.  
  343.  
  344.  
  345.  
  346.  
  347.  
  348.  
  349.  
  350.  
  351.  
  352.  
  353.  
  354.  
  355.  
  356.  
  357.  
  358.  
  359.  
  360.  
  361.  
  362.              
  363. Page 5                                                         ZipLab Plus 1.8b
  364.  
  365.  
  366.  
  367. NEW!! IN THIS VERSION *********************************************************
  368.  
  369.                           ZipLab PLUS Version 1.8b
  370.                           
  371. * Changes to your configuration ARE required for this release!                           
  372.  
  373. * Several Sysops were having problems with ZipLab hanging or even 
  374.   locking up their computers from time to time.  This seemed to be 
  375.   most evident when running the latest 2.41 version of DesqView, but 
  376.   on a few systems, was independant of DV.  The problem for these few 
  377.   systems seems to have started with version 1.6 of ZipLab Plus, and 
  378.   the major change in that version was the new serial routines I 
  379.   introduced to allow for non-standard commport IRQ's.  I have gone 
  380.   back to the previous version of the routines at this time, and would 
  381.   like feedback on whether or not this corrects the problem for those 
  382.   systems which were hanging...  If you in fact have a non-standard 
  383.   IRQ for your commport, and ZipLab 1.8 is working ok for you, STAY 
  384.   with that version. I hope to have the situation straightened out for 
  385.   the next full version, so we can have the non-standard commports as 
  386.   well as a stable product on as many machines as possible.  If you 
  387.   have had problems with ZipLab crashing, please give this version a 
  388.   try to see if it corrects your problem.
  389.   
  390. * Other problems which some people are experiencing is that ZipLab 
  391.   will return ERRORs 9, 5 or 6, will see all uploaded files as having 
  392.   bad CRC values, won't replace the description with File_Id.Diz, or 
  393.   or won't add the date information to the description.  These are 
  394.   almost certainly due to not having enough RAM memory free when 
  395.   ZipLab is executing.  If you are running under a multi-tasker 
  396.   (DesqView, OmniView etc...) and are having the problems described 
  397.   above, you MUST use the "SET PCB=/SWAP" command in either your 
  398.   Autoexec.Bat or in each nodes Board.Bat.  This will cause PCBoard to 
  399.   get out of the way when SHELL'ing out to ZipLab, and you should then 
  400.   have plenty of memory.  If you are having ANY problems with ZipLab 
  401.   Plus, please try the /SWAP setting above, and see if that corrects 
  402.   them.  ZipLab does require a fair amount of memory (like 160K), and
  403.   then ZipLab shells out to run PKUNZIP (another 80K or so).
  404.  
  405. * One other note.  I have tried to build in as much error trapping as 
  406.   possible, and will be looking to improve this for the next version. 
  407.   Howver, if something gets by me, and you walk in to an "Error in 
  408.   module PTEST at address xxxx:xxxx - Hit any key to return to system" 
  409.   message, on your computer, PLEASE REBOOT at this time.  If I am 
  410.   unable to catch the error and exit through my error traps, your 
  411.   serial port may not be left in the proper state.  This almost 
  412.   certainly will cause a "hang" at some point later on.
  413.   
  414. * Please re-run SETUP, or simply remove the second line from any of your
  415.   PTEST.CFG files.  This line is in support of the IRQ number, and must
  416.   be removed for ZipLab 1.8b to function properly.
  417.   
  418.     
  419.                             
  420.                           ZipLab PLUS Version 1.8
  421.                           
  422. * NO changes to your configuration are required for this release! 
  423.  
  424. * The DATE CHECKING was moved up in the process, just after the CRC 
  425.   checking of the file.  This way, if a file is going to fail in any 
  426.   case becuase it is old, no reason to wait for all the other testing 
  427.   and modifications.  I do need to at least CRC check first, as a bad 
  428.   archive will at best cause my date checking routines to return the 
  429.   wrong date, and at worst cause a program crash.
  430.   
  431. * Some other minor cosmetic changes, and some tightening up of the code
  432.   to improve speed.
  433.   
  434.   
  435.   
  436.                           ZipLab PLUS Version 1.7
  437.                           
  438. * NO changes to your configuration are required for this release!
  439.                           
  440. * This version is primarily to fix some problems ZipLab was having with
  441.   file descriptions and ProDoor.  All of the options for adding to the
  442.   file descriptions, as well as replacement with FILE_ID.DIZ (if desired)
  443.   are now fully supported in both PCBoard 14.5a and ProDoor 3.4.  Sam Smith
  444.   is apparently considering changing from the current $DOOR.NAM method to
  445.   a more "PCBoard'ish" UPDESC.[node] method of storing file descriptions,
  446.   and if/when this happens additional changes will probably be required.
  447.   
  448. * The sample PTEST.CFG file which is included in the ZLABP_xx.ZIP archive
  449.   is now fully commented.  This is to help those who wish to manually 
  450.   change existing .CFG file(s), instead of recreating with SETUP.EXE.  The
  451.   ";" characters and the comments which follow can be left in the .CFG 
  452.   file, or removed as is your preference.  Please don't use the ";" character
  453.   in actual .CFG data (like your BBS name), or ZipLab will parse the .CFG
  454.   file incorrectly.  The file created by SETUP.EXE will not contain comments.
  455.   
  456. * In testing the current version of ZipLab, It has been determined that the
  457.   memory requirements are between 146,052 and 159,480 bytes of RAM, depending
  458.   on the number of members in the archive.  Keep in mind that you will need
  459.   this much free RAM, as well as another copy of COMMAND.COM when PCBoard
  460.   shells out to run PCBTEST.BAT.  See the notes under "Quick Start" above
  461.   for some suggestions on managing memory with PCBoard.
  462.   
  463. * Several SysOps have expressed some confusion about the registration process
  464.   for ZipLab.  There are NO "keys", "serial numbers" or "registered versions"
  465.   required for ZipLab.  ZipLab as downloaded from any BBS is fully functional,
  466.   with no advertising, "beg screens", delays or registration reminders.  It
  467.   is expected that you will register ZipLab if you are going to use it, and
  468.   when you do, you will be entered into my database for purposes of receiving
  469.   what I hope is quick and friendly support.  Once registered for any 1.x
  470.   version of ZipLab, you are automatically entitled to run future versions,  
  471.   but you will need to do so before I release version 2.0.  Registration of
  472.   version 2.0 will cost more than the nominal $10.00 I have charged while
  473.   in the "development" 1.x version, and after 2.0 is released I will accept
  474.   no further registrations of 1.x.
  475.   
  476.   
  477.   
  478.                           ZipLab PLUS Version 1.6
  479.  
  480. * Changes to your configuration ARE required for this release!                           
  481.  
  482. * Version 1.5 was opening the CALLER file in exclusive mode, which would
  483.   cause a conflict with PCBoard in the SHELL mode.  I now open the 
  484.   CALLER file in shared mode, and the "error 70" should be eliminated.
  485.  
  486. * ZipLab will now support non-standard commport IRQ addresses.  I have 
  487.   added a line to the .CFG file to allow you to set the IRQ for the 
  488.   commport.  ZipLab will get the commport itself by looking in 
  489.   PCBoard.Dat.  ZipLab will obey the IRQ setting you specify, but will 
  490.   use standard Base Port addresses.  If your commport has non-standard 
  491.   IRQ AND Base Port addresses, ZipLab will most probably not function 
  492.   properly.  If you have a standard commport, and are using COM1-COM4,
  493.   please just enter a '0' (zero) in the field when prompted by SETUP.
  494.   
  495.   
  496.                           ZipLab PLUS Version 1.5
  497.  
  498. * You must run SETUP.EXE and create a new .CFG file for this version!
  499.                            
  500. * A record of files which fail ZipLab's testing process will now be
  501.   written to the CALLER file for the current node.
  502.  
  503. * Users can now run the TEST command in PCBoard to check files before 
  504.   downloading, but the files will not be moved offline if they fail 
  505.   DATE checking.  The user will be informed of any problems with the 
  506.   file, and names of files which fail TEST will be written to the 
  507.   CALLER file for the  current node.  A Change is required to your 
  508.   PCBTEST.BAT file to support this feature!
  509.   
  510.   @ECHO OFF
  511.   PTEST %1 C:\P2\PTEST.CFG %2
  512.                            ^^NEW!!
  513.   
  514.   Note the additon of %2 at the end of the command line.  PCBoard will
  515.   pass the word TEST as %2 when using the TEST command from the board,
  516.   and will pass nothing in %2 when testing an upload.
  517.                            
  518. * The user was being displayed the name of the file including drive and
  519.   path when a file failed testing.  This has been modified to show only
  520.   the filename, for security reasons.  
  521.  
  522. * In order to allow maximum flexibility in using GIFTEST for testing 
  523.   .GIF files, ZipLab will no longer make ANY assumptions about what
  524.   command lines need to be passed to GIFTEST.EXE.  You should use
  525.   GTSETUP.EXE (from GIFTEST) to configure GIFTEST, and then use the
  526.   new item in the PTEST.CFG file to pass any additonal parameters you
  527.   require.  Please run SETUP.EXE to effect the change required in the
  528.   PTEST.CFG file, and read the documentation for GIFTEST to see what
  529.   command line parameters you require.
  530.   
  531.   
  532.  
  533.                            ZipLab PLUS Version 1.4
  534.                             
  535. * A CONFIGURATION CHANGE IS REQUIRED FOR THIS VERSION!!!  RUN SETUP.EXE!
  536.  
  537. * Added an entry in the .CFG file for the type of information to appear at 
  538.   the beginning of the line added to the file description.  The choices 
  539.   are:
  540.   
  541.                    ENTRY:    MEANING:
  542.                    
  543.                    CRC       The CRC32 value of the archive file.
  544.                    FILES     The number of files in the archive
  545.                    NONE      Insert only the date information.
  546.                               
  547.   Note that if you see two files with the same CRC32, they are the SAME 
  548.   file, even if the names and dates are different.  How you use this 
  549.   information is up to you for now, although I plan for a future release 
  550.   of ZipLab to have the capability to search a database of existing file 
  551.   CRC32's on your system, and reject re-named duplicates.
  552.   
  553.   Note as well that calculating the CRC32 will cause a momentary delay 
  554.   during the "checking CRC" process.  The delay will be a second or two on 
  555.   a small file, and up to 15-20 seconds on a file around 1meg.
  556.   
  557. * Added an entry in the .CFG file which if "Y" will search the archive 
  558.   for FILE_ID.DIZ. If FILE_DIZ is found, ZipLab will replace the 
  559.   description left by the user with the description contained in 
  560.   FILE_ID.DIZ.  Set this to "N" if you do not wish this feature, but
  561.   I do strongly recommend it.  FILE_ID.DIZ is a standard format file
  562.   
  563. Page 6                                                         ZipLab Plus 1.8b
  564.  
  565.  
  566.   containing the author's description of the archive contents.  Why not
  567.   get the description from the "horses mouth"?  Not all Shareware authors
  568.   are inserting FILE_ID.DIZ yet, but it is becoming increasingly popular.
  569.   
  570. * Please run SETUP.EXE to create the new .CFG file(s) for your system.
  571.   
  572.   
  573.                               
  574.                            ZipLab PLUS Version 1.3
  575.  
  576. * No configuration file changes required for this version.
  577.  
  578. * Corrected several things which were not working correctly.  
  579.  
  580.   1)  If a file failed any test, ZipLab was doing everything it was supposed
  581.       to, but then exiting with an ERROR 76.  Fixed.
  582.   2)  A flag on ARJ was set wrong, so that imbedded files with the same 
  583.       name as a file in the top level .ARJ would cause an "overwrite?" pause.
  584.   3)  SCAN'ing for virus infestation was not working properly in "imbedded"
  585.       archives.  ZipLab will now properly SCAN executables and overlays 
  586.       contained in imbedded archives.
  587.   4)  I broke CRC checking in archives and .TD0 files in the 1.2 version.
  588.       This has been fixed.  Archives and .TD0 files inside the top level
  589.       archive will now be CRC checked properly.
  590.   5)  I was previously only running SCAN against .EXE and .COM files in
  591.       the archive.  I have added .OVL (which SCAN recognizes as executable).                        
  592.       
  593.                             
  594.                             ZipLab PLUS Version 1.2
  595.                             
  596.                             
  597. * No configuration file changes required for this version.
  598.  
  599. * Fixed a tricky little problem with an ASM routine I use to RD directories.
  600.   The routine was not properly killing the directory if SET ZIPLAB= was used
  601.   to set the "work" directory to a RAM drive.  This should now work fine.
  602.   There were other instances where some machines (or DOS') were having 
  603.   trouble with removing the "work" directory.  These are also fixed...
  604.   
  605. * Fixed a problem where PKUNZIP was stopping with a "do you want to overwrite?"
  606.   message (which we couldn't see), if a file had imbedded paths with files of
  607.   the same name in different paths.  This should no longer be a problem.
  608.   
  609. * The LHARC program is now called LHA.EXE in newer versions.  ZipLab will 
  610.   work properly with either LHARC.EXE or LHA.EXE, but defaults to LHA.EXE.
  611.   
  612.                                   
  613.                             ZipLab PLUS Version 1.1
  614.                             
  615. * No configuration file changes required for this version.
  616.  
  617. * I had left in a lot of "local" display of the testing process, so that I
  618.   could get useful debugging information back from my users.  I have now
  619.   removed as much as possible of the local displays, and the process should
  620.   look a lot less jerky to the watching sysop.
  621.   
  622. * Added a the ability to use ".*" as one of the extensions which will be
  623.   
  624. Page 7                                                         ZipLab Plus 1.8b
  625.  
  626.   
  627.   passed without archive testing.  If you put ".*" in using Setup.Exe, ALL
  628.   files will be passed.  Files passed with this method OR by specifing
  629.   particular extensions in PTest.Cfg will still be SCAN'd for virus'.  
  630.   
  631. * Fixed a problem where in LOCAL mode using wildcards, a directory which
  632.   contained a mixture of archive types (ZIP, ARJ, LZH) would cause problems
  633.   after testing the first type.
  634.   
  635. * Some users were having problems reassigning the "working" directory.  This
  636.   is by default PTEST.DIR under the current directory (C:\PCB\PTEST.DIR\ for
  637.   most sysops), but can be changed to another directory with an environment
  638.   variable.   In your Autoexec.Bat, the line "SET ZIPLAB=d:\path" will allow
  639.   any drive and directory to be used for the "working" directory.  PLEASE,
  640.   remember that this directory will be used and DELETED when the process is
  641.   done.  Several people tried to use C:\PCB or just C:\ and experienced 
  642.   unfortunate effects.  I have tested ZipLab PLUS with a ramdrive as the
  643.   "working" directory, and it seems to work fine.  There may be a problem
  644.   with directories containing a "." in early versions of DOS. if you are
  645.   not running DOS 4.0 or later, and are having problems with ZipLab Plus,
  646.   you may want to try reassigning to another directory name.
  647.   
  648. * Descriptions will not be modified if you are not running PCBoard 14.5(a)
  649.   or later.  Early 14.5 versions didn't save the descriptions in the same
  650.   location during the testing process, and ZipLab Plus won't find them.
  651.                             
  652.                             
  653.                             ZipLab PLUS Version 1.0
  654.                 
  655. * Configuration file changes required for this version! (from old ZipLab)
  656.  
  657. * This is the new ZipLab PLUS!  A lot of hard work has gone into this and 
  658.   earlier versions,  and I will be requiring a *REGISTRATION FEE* with 
  659.   this version.  See REGISTER.DOC for details on how to register ZipLab 
  660.   PLUS.
  661.                 
  662. * ZipLab will now test .ARJ and .LZH files, as well as the .ZIP 
  663.   format.  You will need to have ARJ.EXE and LHA.EXE if you accept 
  664.   these formats, and a change to the .CFG file is *REQUIRED* to tell 
  665.   PTEST where they are.  You must put them in the PTEST.CFG file, even 
  666.   if you don't accept these formats,  and don't have the programs... 
  667.   Just lie to it.
  668.                 
  669. * ZipLab now fully supports ProDoor as well as PCBoard.
  670.  
  671. * You may now run ZipLab while out of the bulletin board system and use 
  672.   wildcards (* or ?) in the testing procedure. This will allow you to test 
  673.   existing archive file(s) on your system.  *NO* changes will be made to 
  674.   existing descriptions. To enable this feature, place the word LOCAL at 
  675.   the end of the PTEST command line.
  676.  
  677.   EXAMPLE: C:\ZIPLAB>PTEST m:\pcb\dir1\*.zip ptest.cfg LOCAL
  678.                 
  679. * ZipLab will now SCAN archives inside archives to test for virus 
  680.   infestation.
  681.   
  682. * You may now have rejected uploads left in your private directory if you 
  683.                 
  684. Page 8                                                         ZipLab Plus 1.8b
  685.  
  686.   
  687.   prefer this setup.  Set the "holding" directory  to the location of your 
  688.   "private" or "upload"  directory  (whichever you wish),  and the file(s) 
  689.   will remain there. The description(s) will be posted to your "private" 
  690.   dir file.  This corrects a situation where sysops trying to do this with 
  691.   earlier releases of ZipLab would lose the rejected file.
  692.                 
  693. * By default, ZipLab will use a directory called PTEST.DIR under the 
  694.   current directory for unzip'ing and testing purposes.  This directory 
  695.   will be erased and removed by ZipLab at the end of the run.  If you wish 
  696.   to use another directory for this purpose (like a RAM drive to improve 
  697.   speed), set the DOS environment variable "ZIPLAB".  
  698.  
  699.   EXAMPLE:  SET ZIPLAB=E:\WORKDIR
  700.  
  701. * You may choose to add a file to the archive package, by adding the 
  702.   appropriate information to the PTEST.CFG file.  I am opposed to this 
  703.   practice, but don't desire to tell anyone how to run their shop.
  704.  
  705. * The ORIGINAL file date of the archive file is now retained. Earlier 
  706.   versions of ZipLab would set the archive file date  to the date of the 
  707.   newest member in the archive.  This was required for age testing, but is 
  708.   no longer.
  709.                 
  710. * ZipLab will NOT leave behind  "hidden,  read-only  or  system" files 
  711.   which were imbedded in archives.  They will be tested, and properly 
  712.   deleted when the tests are finished.
  713.                 
  714. * ZipLab now uses GIFTEST.EXE to test .GIF files (if permitted).  This 
  715.   program by Dave Navarro will allow you to set up a GIFTEST.CFG file - 
  716.   giving you even more control over  .GIF  testing.  An addition to your 
  717.   PTEST.CFG file is required to support this.  Please read the docs with  
  718.   GIFTSTxx.ZIP  for details  on  how to best set up the GIFTEST.CFG file. 
  719.   YOU MUST REGISTER GIFTEST TO USE IT!
  720.                 
  721. * You may now put all BBS advertising file  names  into a text  file, one 
  722.   on each line.  In PTEST.CFG, place an "@" before the name of this text 
  723.   file, and ZipLab will delete all listed advertising  files in one pass.  
  724.   THIS IS MUCH FASTER for those with multiple advertising files to reject.
  725.  
  726.  
  727.  
  728.  
  729. ***********************************************************************************************
  730.  
  731.    This program was written in QuickBasic 4.5, with some help from 
  732. Hammerly Computing's ProBas 4.01.   I have also included a few utilities 
  733. which PTEST will use in the course of testing.  These utilities are the 
  734. property of the authors, and you are strongly requested to register them 
  735. if you continue to use ZIPLAB PLUS.
  736.  
  737.                              Jeffrey S. Morley
  738.                            The Interconnect BBS
  739.                                (703)425-2505
  740.  
  741.             PLEASE SEE REGISTER.DOC FOR REGISTRATION INFORMATION
  742.  
  743.                 (C)Copyright 1989-1991 by Jeffrey S. Morley
  744.  
  745. Page 9                                                         ZipLab Plus 1.8b
  746.  
  747.