New Information Regarding Qualitas MAX 8
New information since the Release
This document contains new information acquired since the release of
Qualitas MAX 8. Please watch our on-line services for an upgrade patch
that will address these problems.
ROMSearch may fail with an internal system error 01E0:xxxx on some
Pentium systems.
Work around this problem by not running ROMSearch or by adding the new
keyword NOPNP to the 386MAX.PRO file in your Qualitas MAX directory.
When you receive this error, just reset the system. Your system will
boot into Maximize (where it left off). When you see the message
"ROMSearch needs to identify your mouse...", press the escape key and
Maximize will run to completion. If you prefer, you may use any text
editor to edit the 386MAX.PRO file in the Qualitas MAX directory to
add the keyword NOPNP to allow ROMSearch to run successfully on these
systems.
Rerunning Qualitas MAX Setup from the icon sometimes causes a sharing
violation even if no files are copied.
This message occurs because some of our own files may be open when you
rerun Setup. If you encounter this sharing violation, click on the
Cancel button. Setup continues and is not affected by this message.
During Setup, clicking on Enable EMS may have no effect in the final
configuration of Qualitas MAX.
Expanded memory may not be present or available, even if you requested
it during Setup. Use the DPMI/EMS tab in Qualitas MAX Toolbox to
enable EMS memory and rerun Maximize. You must rerun Maximize to
reconfigure high DOS memory.
MAXedit may fail when trying to print multiple times.
After printing once from MAXedit, clicking on the print button may
have no effect. Exit MAXedit and reopen it when you need to edit more
than one file.