home *** CD-ROM | disk | FTP | other *** search
/ Explore the World of Soft…e: Engineering & Science / Explore_the_World_of_Software_Engineering_and_Science_HRS_Software_1998.iso / programs / pwrplant / quest150.exe / KINGS59.QUE < prev    next >
Text File  |  1988-03-21  |  2KB  |  97 lines

  1. TVA's Kingston Units 5-9 (200 MW nominal)
  2. * this is a QUEST configuration file
  3. 5 one HP, one IP, and one LP turbine, with reheat
  4. * Tb    Pb      Fb     Tr    BP
  5. 1050. 1815.  1287000. 1050. 2.00
  6. *HP turbine stages
  7.  2
  8. *HP turbine type
  9.  2
  10. *HP turbine generator connection
  11.  1
  12. *HP turbine flow factor(s)
  13.  559.5
  14.  318.1
  15. *HPT throttle leak to reheater exit/IPT inlet
  16.  -15800.
  17. *HPT throttle leak to SSR
  18.    1420.
  19. *HPT HP seal leak to SSR
  20.       0.
  21. *HPT HP seal leak to open feedwater heater
  22.       0.
  23. *HPT HP seal leak to HPT exit/reheater inlet
  24.   -1170.
  25. *HPT LP seal leak to open feedwater heater
  26.   -3600.
  27. *HPT LP seal leak to SSR
  28.   -2300.
  29. *IP turbine stages
  30.  1
  31. *IP turbine type
  32.  4
  33. *IP turbine generator connection
  34.  1
  35. *IP turbine flow factor(s)
  36.  218.1
  37. *IPT LP seal leak to open feedwater heater
  38.   -3300.
  39. *IPT LP seal leak to SSR
  40.    4380.
  41. *cross-over pressure drop factor
  42.    5.00
  43. *LP turbine stages
  44.  6
  45. *LP turbine type
  46.  5
  47. *LP turbine generator connection
  48.  1
  49. *LP turbine flow factor(s)
  50.   91.12
  51.   50.83
  52.   33.79
  53.   13.77
  54.    8.192
  55. *LPT LP seal leak to SSR
  56.     215.
  57. *last stage annulus area in square feet (single flow)
  58.   41.10
  59. *number of annuli
  60.  3
  61. *FP turbine stages
  62.  0
  63. *generator 1 type
  64. 1 3600-rpm conventionally cooled
  65. *generator 1 rated KVA
  66.   200000.
  67. *makeup flow
  68.  -25720.
  69. *makeup injection
  70. D=deaerator
  71. *boiler pressure drop and efficiency
  72. 15.0  88.6
  73. *reheater pressure drop and efficiency
  74. 10.0  88.6
  75. *heat exchanger type, TTD, DCA, shell pressure drop
  76. * type 1: no drain inlet, type 2: drain inlet, type 3: open
  77. *type  TTD  DCA   DP
  78.    1    .0 10.0  7.8
  79.    2   5.0 10.0  5.0
  80.    2    .0 10.0  5.0
  81.    3    .0   .0  7.9
  82.    1   5.0 10.0  7.9
  83.    2   5.0   .0  7.8
  84.    1   5.0   .0  7.9
  85.    2   5.0   .0  7.8
  86. NO, last heat exchanger before GSC does not drain to condenser
  87. *boiler feedpump efficiency
  88.  85.0
  89. *SSR flow to GSC
  90.    2190.
  91. *SSR flow to condenser
  92.       0.
  93. *SSR flow to LP turbine seals
  94.    1955.
  95. *service load (+KW or -%)
  96.     -5.00
  97.