TVA's John Sevier Units 1-3 (200 MW nominal)
* this is a QUEST configuration file
5 one HP, one IP, and one LP turbine, with reheat
* Tb Pb Fb Tr BP
1050. 1815. 1287000. 1050. 2.00
*HP turbine stages
2
*HP turbine type
2
*HP turbine generator connection
1
*HP turbine flow factor(s)
559.5
318.1
*HPT throttle leak to reheater exit/IPT inlet
-15800.
*HPT throttle leak to SSR
1420.
*HPT HP seal leak to SSR
0.
*HPT HP seal leak to open feedwater heater
0.
*HPT HP seal leak to HPT exit/reheater inlet
-1170.
*HPT LP seal leak to open feedwater heater
-3600.
*HPT LP seal leak to SSR
-2300.
*IP turbine stages
1
*IP turbine type
4
*IP turbine generator connection
1
*IP turbine flow factor(s)
218.1
*IPT LP seal leak to open feedwater heater
-3300.
*IPT LP seal leak to SSR
4380.
*cross-over pressure drop factor
5.00
*LP turbine stages
6
*LP turbine type
5
*LP turbine generator connection
1
*LP turbine flow factor(s)
91.12
50.83
33.79
13.77
8.192
*LPT LP seal leak to SSR
215.
*last stage annulus area in square feet (single flow)
41.10
*number of annuli
3
*FP turbine stages
0
*generator 1 type
1 3600-rpm conventionally cooled
*generator 1 rated KVA
200000.
*makeup flow
-25720.
*makeup injection
D=deaerator
*boiler pressure drop and efficiency
15.0 88.8
*reheater pressure drop and efficiency
10.0 88.8
*heat exchanger type, TTD, DCA, shell pressure drop
* type 1: no drain inlet, type 2: drain inlet, type 3: open
*type TTD DCA DP
1 .0 10.0 7.8
2 5.0 10.0 5.0
2 .0 10.0 5.0
3 .0 .0 7.9
1 5.0 10.0 7.9
2 5.0 .0 7.8
1 5.0 .0 7.9
2 5.0 .0 7.8
NO, last heat exchanger before GSC does not drain to condenser
*boiler feedpump efficiency
85.0
*SSR flow to GSC
2190.
*SSR flow to condenser
0.
*SSR flow to LP turbine seals
1955.
*service load (+KW or -%)
-5.00