home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
Explore the World of Soft…e: Engineering & Science
/
Explore_the_World_of_Software_Engineering_and_Science_HRS_Software_1998.iso
/
programs
/
pwrplant
/
quest150.exe
/
GALTIN34.QUE
< prev
next >
Wrap
Text File
|
1988-03-21
|
2KB
|
97 lines
TVA's Gallatin Units 3-4 (300 MW nominal)
* this is a QUEST configuration file
5 one HP, one IP, and one LP turbine, with reheat
* Tb Pb Fb Tr BP
1050. 2015. 1954500. 1050. 2.00
*HP turbine stages
2
*HP turbine type
3
*HP turbine generator connection
1
*HP turbine flow factor(s)
431.2
264.6
*HPT throttle leak to reheater exit/IPT inlet
0.
*HPT throttle leak to SSR
1600.
*HPT HP seal leak to SSR
700.
*HPT HP seal leak to open feedwater heater
0.
*HPT HP seal leak to HPT exit/reheater inlet
-19500.
*HPT LP seal leak to open feedwater heater
0.
*HPT LP seal leak to SSR
500.
*IP turbine stages
3
*IP turbine type
4
*IP turbine generator connection
1
*IP turbine flow factor(s)
116.8
76.77
44.60
*IPT LP seal leak to open feedwater heater
0.
*IPT LP seal leak to SSR
700.
*cross-over pressure drop factor
2.00
*LP turbine stages
4
*LP turbine type
5
*LP turbine generator connection
1
*LP turbine flow factor(s)
26.40
11.03
6.634
*LPT LP seal leak to SSR
0.
*last stage annulus area in square feet (single flow)
41.1
*number of annuli
3
*FP turbine stages
0
*generator 1 type
3 3600-rpm conductor-cooled
*generator 1 rated KVA
275000.
*makeup flow
-39100.
*makeup injection
D=deaerator
*boiler pressure drop and efficiency
15.0 90.2
*reheater pressure drop and efficiency
10.0 90.2
*heat exchanger type, TTD, DCA, shell pressure drop
* type 1: no drain inlet, type 2: drain inlet, type 3: open
*type TTD DCA DP
1 .0 10.0 5.0
2 5.0 10.0 5.0
2 5.0 10.0 5.0
3 .0 .0 5.0
1 5.0 10.0 7.0
2 5.0 .0 5.0
1 5.0 .0 5.0
2 5.0 .0 5.0
NO, last heat exchanger before GSC does not drain to condenser
*boiler feedpump efficiency
85.0
*SSR flow to GSC
2000.
*SSR flow to condenser
0.
*SSR flow to LP turbine seals
0.
*service load (+KW or -%)
-5.00