TVA's Bull Run Steam Plant (950 MW nominal)
* this is a QUEST configuration file
5 one HP, one IP, and one LP turbine, with reheat
* Tb Pb Fb Tr BP
1004. 3515. 6335200. 1000. 1.50
*HP turbine stages
2
*HP turbine type
2
*HP turbine generator connection
1
*HP turbine flow factor(s)
237.20
120.50
*HPT throttle leak to reheater exit/IPT inlet
6000.
*HPT throttle leak to SSR
2000.
*HPT HP seal leak to SSR
-3800.
*HPT HP seal leak to open feedwater heater
-10700.
*HPT HP seal leak to HPT exit/reheater inlet
-35500.
*HPT LP seal leak to open feedwater heater
-4600.
*HPT LP seal leak to SSR
-4200.
*IP turbine stages
1
*IP turbine type
4
*IP turbine generator connection
1
*IP turbine flow factor(s)
39.46
*IPT LP seal leak to open feedwater heater
0.
*IPT LP seal leak to SSR
-6400.
*cross-over pressure drop factor
.00
*LP turbine stages
4
*LP turbine type
7
*LP turbine generator connection
2
*LP turbine flow factor(s)
6.514
1.987
0.910
*LPT LP seal leak to SSR
2400.
*last stage annulus area in square feet (single flow)
123.8
*number of annuli
4
*FP turbine stages
3
*FP turbine type
9
*FP turbine supply (1-7: HPT, 8-14:IPT, 15-21:LPT, 91:B, 93:R)
1
*FP turbine flow factor(s)
449.69
211.18
95.78
*generator 1 type
3 3600-rpm conductor-cooled
*generator 1 rated KVA
475000.
*generator 2 type
4 1800-rpm conductor-cooled
*generator 2 rated KVA
475000.
*makeup flow
0.
*makeup injection
H=hotwell
*boiler pressure drop and efficiency
15.0 90.5
*reheater pressure drop and efficiency
10.0 90.5
*number of heat exchangers
9
*heat exchanger type, TTD, DCA, shell pressure drop
* type 1: no drain inlet, type 2: drain inlet, type 3: open
*type TTD DCA DP
1 .0 10.0 8.1
2 5.0 10.0 5.0
2 5.0 10.0 6.9
2 5.0 10.0 7.1
3 .0 .0 7.0
1 5.0 10.0 7.9
2 5.0 10.0 8.0
2 5.0 10.0 7.8
YES, last heat exchanger before GSC drains to condenser
*boiler feedpump efficiency
85.0
*SSR flow to GSC
4400.
*SSR flow to condenser
0.
*SSR flow to LP turbine seals
4800.
*service load (+KW or -%)
-2.50