home *** CD-ROM | disk | FTP | other *** search
/ Current Shareware 1994 January / SHAR194.ISO / networks / wsdos2.zip / WSDOS2.EXE / NLS / ENGLISH / DOSRQSTR.MSG (.txt) next >
Novell DOS Client Message  |  1993-06-02  |  10KB  |  171 lines

  1. DOS Client Message File: DOSRqstr 0, Tran 0
  2. The message file %s is invalid.
  3. The program cannot be loaded.
  4. CoPyRiGhT=(C) Copyright 1993 Novell, Inc.  All Rights Reserved.
  5. (C) Copyright 1993 Novell, Inc.  All Rights Reserved.
  6. Patent pending.
  7. %s.VLM is not loaded.  The %s.VLM file cannot be loaded before
  8. %s.VLM.  
  9. Load the %s.VLM file first;
  10. then load the %s.VLM file.
  11. In order to load the %s.VLM, one of the following VLMs
  12. must be loaded: %s
  13. The VLM.EXE file is already loaded.  The VLM.EXE file cannot
  14. be reloaded.  If you want to load VLM.EXE with a different configuration,
  15. unload VLM.EXE first with the /U parameter and then try loading the VLM.EXE
  16. file.
  17. The VLM.EXE file is pre-initializing the VLMs.
  18. There is insufficient memory to load the VLMs.  The VLM.EXE file
  19. cannot be loaded.  Reconfigure the VLMs to be loaded in the NET.CFG file
  20. and then try to load the VLM.EXE file.
  21. Available command line options:
  22. /?     Display this help screen.
  23. /U     Unload the VLM.EXE file from memory
  24. /C=[path\]filename.ext
  25.        Specify a configuration file to use (Default is NET.CFG).
  26. /Mx    The memory type the VLM.EXE file uses where x is one of the following:
  27.        C = Conventional memory.
  28.        X = Extended memory (XMS).
  29.        E = Expanded memory (EMS).
  30. /D     Display the VLM.EXE file diagnostics.
  31. /PS=<server name>
  32.        Preferred server name to attach to during load.
  33. /PT=<tree name>
  34.        Preferred tree name to attach to during load.
  35. /Vx    The detail level of message display where x is one of the following:
  36.        0 = Display copyright and critical errors only.
  37.        1 = Also display warning messages.
  38.        2 = Also display VLM module names.
  39.        3 = Also display configuration file parameters.
  40.        4 = Also display diagnostics messages.
  41. An invalid command line parameter was specified.
  42. The VLM.EXE file v%d.%.2d is currently loaded
  43. The VLM.EXE file is not currently loaded.
  44. VLM transient switch count : %d
  45. VLM call count             : %d
  46. VLM current ID             : %.4Xh
  47. VLM memory type            : %s
  48. VLM modules loaded count   : %d
  49. VLM block ID (0 if CON)    : %.4Xh
  50. VLM transient block        : %.4Xh
  51. VLM global seg (0 if CON)  : %.4Xh
  52. VLM async queue (h, t, s)  :
  53. VLM busy queue (h, t, s)   :
  54.  %.4X:%.4X, %.4X:%.4X, 
  55. VLM re-entrance level      : %d
  56. VLM full map count         : %d
  57. VLM Control Block information      Address   TMemSize  GMemSize  SMemSize 
  58. ID   Flag Func Maps Call TSeg GSeg Low  High Para K    Para K    Para K   
  59. ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
  60. %.4X 
  61. %.4X %.4d 
  62. Total                                        %.4X      %.4X
  63. Maximum                                      %.4X      %.4X      %.4X
  64. A task switcher has been detected in memory.  The VLM.EXE file
  65. cannot be loaded under a task switcher.  Exit the task switcher; then load
  66. the VLM.EXE file.
  67. %s%d : Network error on server 
  68.                                       
  69. Check network cabling or server status.
  70. The VLM.EXE file is not loaded.  VLM.EXE cannot be unloaded.
  71. The loaded VLM.EXE file has a different version.  VLM.EXE cannot
  72. be unloaded.  Make sure the VLM.EXE file you are using has the same version
  73. number and then try to unload VLM.EXE.
  74. The loaded VLM.EXE file indicates it is unsafe to execute an
  75. unload for VLM number %.4Xh.  VLM.EXE will not be unloaded.  Unload all
  76. memory resident programs (TSRs) that were loaded after the VLM.EXE file
  77. and then try to unload VLM.EXE.
  78. The VLM.EXE file has been successfully removed.
  79. The VLM.EXE file cannot use expanded memory (EMS).  VLM.EXE will
  80. use an alternate memory scheme.
  81. The VLM.EXE file is using expanded memory (EMS).
  82. The VLM.EXE file cannot use extended memory (XMS).  VLM.EXE will
  83. use an alternate memory scheme.
  84. The VLM.EXE file is using extended memory (XMS).
  85. The VLM.EXE file cannot use conventional memory.  VLM.EXE will use
  86. an alternate memory scheme.
  87. The VLM.EXE file is using conventional memory.
  88. There is a missing or invalid value for
  89. on line %u of the configuration file.  This entry will be ignored.
  90. Correct the line specified in the configuration file before continuing.
  91. There is a missing or invalid ON/OFF value for
  92. on line %u of the configuration file.  This entry will be ignored.
  93. Correct the line specified in the configuration file before continuing.
  94. There is an invalid string length specified for
  95. on line %u of the configuration file.  This entry will be ignored.
  96. Correct the line specified in the configuration file before continuing.
  97. The parameter specified for the following option was out of range
  98. and has been adjusted.
  99. A duplicate VLM ID was found during VLM load test.  The file
  100. will not be loaded.  Check the VLM= and USE DEFAULTS= parameter specified in
  101. the configuration file before continuing.
  102. %s%d : A file server could not be found.  Check the 
  103. network cabling and the server's status before continuing.
  104. The preferred connection could not be established.  Check the 
  105. PREFERRED SERVER and PREFERRED TREE statement specified in the 
  106. NET.CFG file.  Also check the server's status before continuing.
  107. You are attached to server 
  108.                                           
  109. DOS version is not 3.1 or later.  The NetWare Requester for DOS
  110. cannot be loaded.  Reboot your computer with DOS v3.1 or later; then load
  111. the NetWare Requester for DOS files.
  112. An older version of the shell is loaded.  The NetWare Requester
  113. for DOS cannot be loaded.  Unload the shell; then load the NetWare Requester
  114. for DOS files.
  115. The NetWare DOS Named Pipes Extender is currently loaded. The NetWare
  116. Requester for DOS cannot be loaded.  Unload the NetWare DOS Named Pipes
  117. Extender; then load the NetWare Requester for DOS files.
  118. The IPX interface is not loaded.  The IPXNCP.VLM file cannot
  119. be loaded.  Load the IPXODI.COM file first and then try loading the IPXNCP.VLM
  120. file.
  121. The IPX sockets could not be opened.  The IPXNCP.VLM file cannot
  122. be loaded.  Configure the IPXODI.COM file for enough sockets in the NET.CFG
  123. file and then try to load the IPXNCP.VLM file.
  124. The IPX interface does not support checksums.  The IPXNCP.VLM file will load
  125. successfully without using checksums.  Make sure the installed IPXODI.COM is
  126. version 2.01 or later and that it is not bound to a board configured to use
  127. the ETHERNET_802.3 frame format.
  128. The IPX socket for large internet packets could not be opened.
  129. The IPXNCP.VLM file will load successfully without using large internet
  130. packets.  Configure the IPXODI.COM file for enough sockets in the NET.CFG file
  131. or add LARGE INTERNET PACKETS=OFF to the NET.CFG file; then load the
  132. IPXNCP.VLM file.
  133. DOS is only configured for %d drives, NETX.VLM requires 26 drives
  134. for full functionality.  The NETX.VLM file will load with partial support.
  135. Add LASTDRIVE=Z to the CONFIG.SYS file, reboot the workstation; then
  136. load the NETX.VLM file.
  137. The PRINT.VLM file has not been loaded.  The NETX.VLM file will 
  138. load successfully without print services.  To enable printing services,
  139. load the PRINT.VLM file before loading the NETX.VLM file.
  140. The SECURITY.VLM file has not been loaded.  The NWP.VLM file will
  141. load successfully without NCP signature support.  Load the SECURITY.VLM file
  142. before loading the NWP.VLM file or add SIGNATURE LEVEL=0 to the NET.CFG
  143. file; then load NWP.VLM.
  144. The SECURITY.VLM file must be loaded before any other NetWare
  145. Protocol module.  The SECURITY.VLM file will not be loaded.  Load the
  146. SECURITY.VLM file before loading any NetWare Protocol modules.
  147. Too much cache is configured.  The FIO.VLM file will reduce the cache
  148. blocks by %d blocks and load successfully.  Check the CACHE BUFFERS and 
  149. BUFFER SIZE parameters in the NET.CFG file; then load the FIO.VLM file.
  150. The IPX interface is not loaded.  The FIO.VLM file will load
  151. successfully without packet burst support.  Load the IPXODI v2.00 or later
  152. to use packet burst or add PB BUFFERS=0 to the NET.CFG file; then load
  153. FIO.VLM.
  154. The LSL interface is not loaded.  The FIO.VLM file will load
  155. successfully without packet burst support.  Load the LSL module or add
  156. PB BUFFERS=0 to the NET.CFG file; then load FIO.VLM.
  157. The IPX socket for packet burst could not be opened.  The FIO.VLM file
  158. will load successfully without packet burst support.  Configure the
  159. IPXODI.COM file for enough sockets in the NET.CFG file or add PB BUFFERS=0
  160. to the NET.CFG file; then load the FIO.VLM file.
  161. The IPX interface is not version 2.00 or later.  The FIO.VLM file
  162. will load successfully without packet burst support.  Load the IPXODI.COM
  163. file version 2.00 or later or add PB BUFFERS=0 to the NET.CFG file; then
  164. load the FIO.VLM file.
  165. The DOS Requester is being loaded in a Windows DOS box.  The FIO.VLM
  166. file will load successfully without packet burst support.
  167. There is an invalid route specified for WORKGROUP NET parameter in
  168. the configuration file.  The PNW.VLM file will load succesfully without a
  169. route specified.  Correct the WORKGROUP NET parameter in the configuration file
  170. before continuing.
  171.