home *** CD-ROM | disk | FTP | other *** search
/ World of Ham Radio 1997 / WOHR97_AmSoft_(1997-02-01).iso / mods / kenwood / asb_text / asb0839.txt < prev    next >
Text File  |  1997-02-01  |  3KB  |  75 lines

  1. ==============================================================================
  2.                              K E N W O O D
  3.    >>>   A M A T E U R   R A D I O   S E R V I C E   B U L L E T I N   <<<
  4. ==============================================================================
  5.  
  6.                         Kenwood Service Centers
  7.  
  8.    Kenwood Service Corporation             Kenwood Service Center, East
  9.    2201 East Dominguez Street              829 Lynnhaven Parkway, Suite 130
  10.    Long Beach, California 90801            Virginia Beach, Virginia 23452
  11.    Telephone 1-310-639-5300                Telephone 1-804-340-1702
  12.  
  13. ==============================================================================
  14.  
  15. BULLETIN # 839
  16. MODEL: TS-180S
  17. SUBJECT: VFO STABILITY
  18.  
  19.  
  20. VFO drift characteristics may be improved by changing a capacitor value and
  21. location in the VFO.
  22.  
  23. 1.   Begin by calibrating the analog dial to the Digital Display at
  24. 14.000.0 MHz.  DO NOT disturb this calibration while working on the VFO.
  25.  
  26. 2.   Turn off the main power and remove the VFO unit by two 3mm hex head
  27. bolts.
  28.  
  29. 3.   Withdraw out the front panel and unplug the leads.
  30.  
  31. 4.   Remove the VFO cover by five Phillips head screws.
  32.  
  33. 5.   Remove C17 from the PCB.  This may be cut flush to the board.
  34.  
  35. 6.   Install the 18 pF yellow cap across the tank coil terminals.  Position
  36. the cap near the coil.
  37.  
  38. 7.   To reassemble, performs steps 3, 2.  Snug all VFO case screws.  A
  39. later complaint of frequency jump would indicate a loose VFO shell.
  40.  
  41. 8.   Turn on the radio and check analog dial calibration against the
  42. Digital Display.  Adjust VC1 (center of the Seal Tape) only if the zero-
  43. point has moved.
  44.  
  45. 9.   VFO linearity final check:  The Digital readout and analog dial should
  46. agree to within +/- 2 kHz at every 100 kHz dial point.
  47.  
  48.  
  49. New Part: 18 pF CC45RC1H180J
  50. Old Part: 18 pF CC45PG1H180J
  51.  
  52. Analog Dial Calibration
  53.  
  54. 1.   Calibrate the main knob to 50 kHz analog against the digital display.
  55.  
  56. 2.   Note the digital error.  If it is more than 2 kHz adjust the VFO
  57. trimmer cap VC1 (center under the sealing tape) to exactly 50.0 on the
  58. digital readout.
  59.  
  60. 3.   Turn the main knob to 450 analog.  If the digital error is less than 2
  61. kHz it is in spec.  If the digital error greater, proceed:
  62.  
  63.      For instance, if the digital error is 14.454.0 (plus 4 kHz), multiply
  64. the error times 4 (16 kHz) and adjust the VFO trimmer cap to the desired
  65. frequency (14.450.0) LESS the error, or 14.434.0.  Next, adjust the VFO
  66. inductor L1 (front under the sealing tape) back up to the desired frequency
  67. of 14.450.0.
  68.  
  69. 4.   If the error in step 3 was in the minus direction, reverse the
  70. direction of correction adjustment.
  71.  
  72. 5.   VFO linearity final check:  The digital readout and analog dial should
  73. agree to within +/- 2 kHz at every 100 kHz dial point.
  74.  