home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
World of Ham Radio 1997
/
WOHR97_AmSoft_(1997-02-01).iso
/
mods
/
kenwood
/
asb_text
/
asb0838.txt
< prev
next >
Wrap
Text File
|
1997-02-01
|
2KB
|
37 lines
==============================================================================
K E N W O O D
>>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<<
==============================================================================
Kenwood Service Centers
Kenwood Service Corporation Kenwood Service Center, East
2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130
Long Beach, California 90801 Virginia Beach, Virginia 23452
Telephone 1-310-639-5300 Telephone 1-804-340-1702
==============================================================================
BULLETIN # 838
MODEL: VFO-230
SUBJECT: OPERATION ON 230 VOLTS
To operate the VFO-230 on 240V AC, the power transformer
primary tap must be rewired from 120V to either the 220V
or 240V tap.
1. Unplug the AC power cable and VFO interconnecting cable.
2. Remove the top cover.
3. Move the AC line from the 120V (Red) to either the 220V
(Green) or 240V (Blue) transformer winding.
4. Change the AC fuse from 0.5A to 0.3A. Tag the power cord
at the back of the unit to indicate that the transformer is
wired for 240V AC, and the power fuse should be 0.3A and
not 0.5A.
5. Replace the top cover and cable up to verify your work.