home *** CD-ROM | disk | FTP | other *** search
/ World of Ham Radio 1997 / WOHR97_AmSoft_(1997-02-01).iso / mods / kenwood / asb_text / asb0063.txt < prev    next >
Text File  |  1997-02-01  |  2KB  |  34 lines

  1. ==============================================================================
  2.                              K E N W O O D
  3.    >>>   A M A T E U R   R A D I O   S E R V I C E   B U L L E T I N   <<<
  4. ==============================================================================
  5.  
  6.                         Kenwood Service Centers
  7.  
  8.    Kenwood Service Corporation             Kenwood Service Center, East
  9.    2201 East Dominguez Street              829 Lynnhaven Parkway, Suite 130
  10.    Long Beach, California 90801            Virginia Beach, Virginia 23452
  11.    Telephone 1-310-639-5300                Telephone 1-804-340-1702
  12.  
  13. ==============================================================================
  14.  
  15. BULLETIN # 63
  16. MODEL: TS-520
  17. SUBJECT: ADDING IF OUT FOR USE WITH THE SM-220 SCOPE
  18.  
  19.               
  20.  The TS-520 and TS-520S transceivers do not provide an IF output signal.
  21.  It is necessary to have this if you want to look at a specific received
  22.  signal on the SM-220 station monitor. The best place to pick up this
  23.  signal is at the tuned output of Q4 on the IF unit (X48-1060-00). A 22 pf
  24.  capacitor should be used for coupling and a 10 Kohm resistor for impedance
  25.  matching. This is shown in the schematic below. The center conductor of
  26.  a 36 cm (14") length of 50 ohm (RG-174/U or similar) cable is connected to
  27.  the pick-up at one end and to pin 7 of the REMOTE socket on the other end.
  28.  The shield is connected to pin 1 of the REMOTE socket and the ground path
  29.  of the IF Unit. A 76 cm (30") 50 ohm cable should be made up with one end
  30.  connected to pins 7 and 1 of the 8 pin plug supplied with the transceiver
  31.  and BNC connector on the other end. The BNC connector will be plugged into
  32.  the vertical input jack on the front of the SM-220
  33.  
  34.