============================================================================== K E N W O O D >>> A M A T E U R R A D I O S E R V I C E B U L L E T I N <<< ============================================================================== Kenwood Service Centers Kenwood Service Corporation Kenwood Service Center, East 2201 East Dominguez Street 829 Lynnhaven Parkway, Suite 130 Long Beach, California 90801 Virginia Beach, Virginia 23452 Telephone 1-310-639-5300 Telephone 1-804-340-1702 ============================================================================== BULLETIN # 63 MODEL: TS-520 SUBJECT: ADDING IF OUT FOR USE WITH THE SM-220 SCOPE The TS-520 and TS-520S transceivers do not provide an IF output signal. It is necessary to have this if you want to look at a specific received signal on the SM-220 station monitor. The best place to pick up this signal is at the tuned output of Q4 on the IF unit (X48-1060-00). A 22 pf capacitor should be used for coupling and a 10 Kohm resistor for impedance matching. This is shown in the schematic below. The center conductor of a 36 cm (14") length of 50 ohm (RG-174/U or similar) cable is connected to the pick-up at one end and to pin 7 of the REMOTE socket on the other end. The shield is connected to pin 1 of the REMOTE socket and the ground path of the IF Unit. A 76 cm (30") 50 ohm cable should be made up with one end connected to pins 7 and 1 of the 8 pin plug supplied with the transceiver and BNC connector on the other end. The BNC connector will be plugged into the vertical input jack on the front of the SM-220