DESCRIPTION of FIXES in the APPLETTS FIX DISKETTE
APAR= IC08799 NETDELETE (NETLOGONASN) FUNCTION DELETES ALL OF
A USERS LOGON ASSIGNMENTS INSTEAD OF JUST THE ONE FOR THE ALIAS SPECIFIED.
When using the LS 4.0 LSRXUTIL applett, the NetDelete function
deletes all logon assignments associated with a user and not
just the one specified for the alias.
APAR= IC09278 NEW FIXES FOR REXX (NETSETINFO AND NETGETINFO CHANGES).
NetSetInfo:NETUSER does not allow LOGON_SERVR as a parameter to set.
NetGetInfo:NETUSER returns "ALL" for logon_server, to be
changed to \\*.
APAR= IC09777 LSRXUTL.30 RXSPLENUMQUEUE FUNCTION RESULTS IN A
NON-ZERO RETURN CODE OF 2.00.01 OR A STRING OF QUESTION MARKS.
When using the LSRXUTL.30 function RxSplEnumQueue, the user gets
a non-zero return code of 02.00.01 or a string of question marks.
APAR= IC10104 SYS3175 WHEN DELETING ACCESS PROFILE IN ACM.
Customer is using Lan Server 4.0 Entry, with FAT partitions and
WARP. While using the ACM utility that comes with LS 4.0, the system
froze with a SYS3175 access violation after he deleted a directory and its
subdirectory.
APAR= IC10219 When calling the NETSERVERMODAL GET INFO routines
in the LSRXUT.40 DLL, a SYS3175 is generated.
When using the LSRXUTIL applet that comes with the 4.0 productivity aids,
a SYS3175 occurs when calling the NETSERVERMODAL routines.
CS:EIP value=005b:175589b3 CDLIM=1bffffff
APAR= IC10385 UTILITY 'MOVESTUF' GIVES ERROR IN MOVEFILES:DOSCOPY()
WITH RC=3 ON CORRECT SRCDRIVE PATH AND DESTDRIVE PATH.
When using the Productivity tool 'movestuf' to move home directories from
one server to another, you will get an error in MoveFiles:DocCopy()
with a RC=3 on the correct SrcDrive path and on the correct DestDrive
path. Customer has issued a net use for both source and destination
drives. Movestuf asks for the destination path again and after entering
the path information and entering the above error msg is issued.
APAR= IC10807 SYS3175 IN THIN386 WHEN RUNNING IT THE SECOND
TIME DURING CID INSTALL.
During CID upgrade from LAN Server 3.0 Advanced to LAN Server
4.0 Advanced on a system running OS/2 Warp Connect, during the second
execution of THIN386 to install the THIN file system in the service
partition the following error can occur:
SYS 3175 OS/2 SYSTEM ERROR A program encountered an access
violation at 0001447e. THIN386.EXE