ΓòÉΓòÉΓòÉ 1. Notices ΓòÉΓòÉΓòÉ
ΓòÉΓòÉΓòÉ 1.1. Copyright ΓòÉΓòÉΓòÉ
Copyright International Business Machines Corporation, 1992, 1993. All rights
reserved.
Note to U.S. Government Users - Documentation related to restricted rights -
Use, duplication, or disclosure is subject to restrictions set forth in GSA ADP
Schedule Contract with IBM* Corp.
ΓòÉΓòÉΓòÉ 1.2. Edition Notice ΓòÉΓòÉΓòÉ
Second Edition, November 1993.
This edition applies to Version 2.01 of IBM* C/C++ Tools (82G3732, 82G3733,
82G3735, 82G3736) and to all subsequent releases and modifications until
otherwise indicated in new editions. This publication could include technical
inaccuracies or typographical errors. Changes are periodically made to the
information herein; any such changes will be reported in subsequent revisions.
Requests for publications and for technical information about IBM products
should be made to your IBM Authorized Dealer or your IBM Marketing
Representative.
When you send information to IBM, you grant IBM a nonexclusive right to use or
distribute the information in any ways it believes appropriate without
incurring any obligation to you.
ΓòÉΓòÉΓòÉ 1.3. Special Notices ΓòÉΓòÉΓòÉ
References in this help to IBM* products, programs, or services do not imply
that IBM intends to make these available in all countries in which IBM
operates.
Any reference to an IBM licensed program in this help is not intended to state
or imply that only IBM's licensed program may be used. Any functionally
equivalent product, program, or service that does not infringe on any of IBM's
intellectual property rights may be used instead of the IBM product, program,
or service.
Evaluation and verification of operation in conjunction with other products,
except those expressly designated by IBM, is the user's responsibility.
IBM may have patents or pending patent applications covering subject matter in
this help. The furnishing of this help does not give you any license to these
patents.
The following terms, denoted by an asterisk (*) in this help, are trademarks of
the IBM corporation in the United States and/or other countries:
C Set ++
C/C++ FirstStep
IBM
OS/2
Operating System/2
Presentation Manager
WorkFrame/2.
The following terms, denoted by a double asterisk (**) in this help, are
trademarks of the Microsoft Corporation:
Microsoft
Windows.
This help contains examples of data and reports used in daily business
operations. To illustrate them as completely as possible, the examples include
the names of individuals, companies, brands, and products. All of these names
are fictitious and any similarity to the names and addresses used by an actual
business enterprise is entirely coincidental.
ΓòÉΓòÉΓòÉ 2. ------------------------------------------------------------------------------ ΓòÉΓòÉΓòÉ
ΓòÉΓòÉΓòÉ 3. Demangling Compiled C++ Names with CPPFILT ΓòÉΓòÉΓòÉ
When the IBM* C/C++ Tools compiler compiles a C++ program, it encodes all C++
symbolic names to include type and scoping information. This encoding process
is called mangling. The linker uses the mangled names in the object files to
resolve external references using the exported names.
Tools that use the files with mangled names do not have access to the original
source code names, and therefore present the mangled names in their output.
Using a process called demangling, the cppfilt utility converts the mangled
names to their original source code names so that they can be easily
identified.
Note: The demangling routines in the runtime library provided with C/C++ Tools
offer another method for converting mangled names to their original
source code names. You can use these routines to develop tools that
manipulate mangled names. For more information on the demangling
routines, refer to the appendix on Mapping in the IBM C/C++ Tools:
Programming Guide, and the information in the <demangle.h> header file.
ΓòÉΓòÉΓòÉ <hidden> Exported Names ΓòÉΓòÉΓòÉ
Exported names are functions and certain other identifiers that are made
available to programs that call the DLL in which the names are defined.
For more information on how to identify symbolic names for export from a DLL,
refer to the chapter on Building Dynamic Link Libraries in the IBM C/C++ Tools:
Programming Guide.
ΓòÉΓòÉΓòÉ 3.1. Using the CPPFILT Utility ΓòÉΓòÉΓòÉ
The cppfilt utility converts mangled names to demangled names in two separate
modes:
Text Specify the names of one or more ASCII text files to have the cppfilt
substitute demangled names for mangled names wherever it finds them in
the text. Input can also be read from stdin.
Binary Specify the names of one or more object (.OBJ) and library (.LIB)
files to produce demangled output in a format that is suitable for
inclusion in a DLL module definition (.DEF) file.
All output is sent to stdout.
ΓòÉΓòÉΓòÉ 3.2. Text mode ΓòÉΓòÉΓòÉ
Use the cppfilt utility in Text mode when you want to simply substitute
demangled names for mangled names wherever they are found in the text.
To use the cppfilt utility in text mode, type cppfilt followed by any valid
text mode options on the OS/2* command line.
The syntax for the cppfilt command in Text mode is:
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
ΓöÇΓöÇcppfiltΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓö┤ΓöÇΓöÇΓöÇ
ΓööΓöÇΓöÇ/optionΓöÇΓöÇΓöÇΓöÿ
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
ΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ
ΓööΓöÇΓöÇtext-filenameΓöÇΓöÿ
ΓòÉΓòÉΓòÉ 3.2.1. Text Mode Options ΓòÉΓòÉΓòÉ
The cppfilt utility has the following options in Text mode:
/C
/H or /?
/M
/Q
/S
/T
/W nnn
Note: You can specify options using the slash form (/S) or the dash form (-S).
ΓòÉΓòÉΓòÉ 3.2.1.1. Class Names ΓòÉΓòÉΓòÉ
Specify the /C option on the cppfilt command line to instruct the cppfilt
utility to demangle stand-alone class names. Stand-alone class names are names
that do not appear within the context of a function name or member variable.
These names are not normally produced by the compiler.
For example, the stand-alone class name Q2_1X1Y would be demangled as X::Y if
you specify the /C option.
If you do not specify the /C option, the default is not to demangle stand-alone
class names.
ΓòÉΓòÉΓòÉ 3.2.1.2. Help ΓòÉΓòÉΓòÉ
Specify the /H or /? option on the cppfilt command line to see a short online
help on the cppfilt command syntax and options.
If you do not specify this option, the default is not to display any online
help.
ΓòÉΓòÉΓòÉ 3.2.1.3. Symbol Map ΓòÉΓòÉΓòÉ
Specify the /M option on the cppfilt command line to produce a symbol map on
standard output. The map contains a list of the mangled names and their
corresponding demangled names. This output follows the normal filtered output.
If you do not specify the /M option, the default is not to produce a symbol
map.
ΓòÉΓòÉΓòÉ 3.2.1.4. Do Not Display Logo ΓòÉΓòÉΓòÉ
Specify the /Q option on the cppfilt command line to suppress the display of
the logo and copyright notice for the cppfilt utility.
If you do not specify this option, the default is to display the logo and
copyright notice.
ΓòÉΓòÉΓòÉ 3.2.1.5. Mangled and Demangled Names Together ΓòÉΓòÉΓòÉ
Specify the /T option on the cppfilt command line to produce side-by-side
demangling. That is, each mangled name is replaced with the demangled name
followed by the original mangled name in the text.
If you do not specify the /T option, the default is to replace the mangled name
by the demangled name only.
ΓòÉΓòÉΓòÉ 3.2.1.6. Width ΓòÉΓòÉΓòÉ
Specify the /W width option on the cppfilt command line to have the cppfilt
utility print the demangled names in fields width characters wide. If the name
is shorter than width, it is padded to the right with blanks; if longer, it is
truncated to width characters.
If you do not specify the /W width option, the default is not to have a fixed
field width when printing demangled names in the text.
ΓòÉΓòÉΓòÉ 3.2.1.7. Special Symbol Names ΓòÉΓòÉΓòÉ
Specify the /S option on the cppfilt command line to instruct the cppfilt
utility to demangle special compiler-generated symbol names.
For example, the compiler-generated symbol name, __ct__3FooFUi, that represents
a constructor for the class Foo, would be demangled as Foo::Foo(unsigned int).
If you do not specify the /S option, the default is not to demangle special
compiler-generated symbol names.
ΓòÉΓòÉΓòÉ 3.2.2. Text Files ΓòÉΓòÉΓòÉ
The file you specify for the cppfilt command in text mode should be an ASCII
text file that is present in the current directory, unless you specify its
path.
If you do not specify a text file, the input is read from stdin.
ΓòÉΓòÉΓòÉ 3.2.3. Output in Text Mode ΓòÉΓòÉΓòÉ
Output in text mode would be the input text with the mangled names replaced by
their demangled names wherever they are found in the text.
All output is sent to stdout.
ΓòÉΓòÉΓòÉ 3.3. Binary Mode ΓòÉΓòÉΓòÉ
Use the cppfilt utility in Binary mode when you want to demangle names in
object (.OBJ) and library (.LIB) files to produce output that is suitable for
inclusion in a DLL module definition (.DEF) file.
To use the cppfilt utility in Binary mode, type cppfilt /B followed by any
valid Binary mode options on the OS/2* command line. The cppfilt utility
switches to the Binary mode of operation when it encounters the /B option.
The syntax for the cppfilt command in Binary mode is:
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
ΓöÇΓöÇcppfiltΓöÇΓöÇ/BΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼Γö┤ΓöÇ
ΓööΓöÇΓöÇ/optionΓöÇΓöÇΓöÇΓöÿ
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
ΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇ.OBJ-filenameΓöÇΓö¼ΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ
ΓööΓöÇΓöÇ.LIB-filenameΓöÇΓöÿ
ΓòÉΓòÉΓòÉ 3.3.1. Binary Mode Options ΓòÉΓòÉΓòÉ
The Binary mode of the cppfilt utility has the following options:
/H or /?
/N
/O [ord]
/P
/Q
/R
/S
/X
Note: You can specify options using the slash form (/R) or the dash form (-R).
ΓòÉΓòÉΓòÉ 3.3.1.1. Operate in Binary Mode ΓòÉΓòÉΓòÉ
Specify /B on the cppfilt command line to instruct cppfilt to operate in Binary
mode.
If you do not specify the /B option, cppfilt will operate in the default Text
mode.
ΓòÉΓòÉΓòÉ 3.3.1.2. Exported Symbols ΓòÉΓòÉΓòÉ
Specify the /X option on the cppfilt command line to include all exported (
EXPDEF ) symbols in the output.
If you do not specify the /X option, the default is not to include exported
symbols in the output.
Note: If you do not specify any of the /X, /R, or /P options, the Binary mode
output will include only the library and object names, without any
symbol names.
ΓòÉΓòÉΓòÉ 3.3.1.3. Referenced Symbols ΓòÉΓòÉΓòÉ
Specify the /R option on the cppfilt command line to include all referenced (
EXTDEF ) symbols in the output.
If you do not specify this option, the default is not to include referenced
symbols in the output.
Note: If you do not specify any of the /X, /R, or /P options, the Binary mode
output will include only the library and object names, without any
symbol names.
ΓòÉΓòÉΓòÉ 3.3.1.4. Public Symbols ΓòÉΓòÉΓòÉ
Specify the /P option on the cppfilt command line to include all public (
PUBDEF, COMDAT, COMDEF ) symbols in the output.
Note: Only the first occurrence of a symbol found within the COMDAT sections
will be included in the output. Subsequent occurrences of the same
COMDAT symbol will appear as comments in the output.
If you do not specify this option, the default is not to include public symbols
in the output.
Note: If you do not specify any of the /X, /R, or /P options, the Binary mode
output will include only the library and object names, without any
symbol names.
ΓòÉΓòÉΓòÉ 3.3.1.5. Special Symbol Names ΓòÉΓòÉΓòÉ
Specify the /S option on the cppfilt command line to instruct the cppfilt
utility to demangle special compiler-generated symbol names.
For example, the compiler-generated symbol name, __ct__3FooFUi, that represents
a constructor for the class Foo, would be demangled as Foo::Foo(unsigned int).
If you do not specify the /S option, the default is not to demangle special
compiler-generated symbol names.
ΓòÉΓòÉΓòÉ 3.3.1.6. Ordinals ΓòÉΓòÉΓòÉ
Specify the /o [ord] option on the cppfilt command line to generate ordinals
after each demangled name. If the optional numeric parameter ord is
specified, cppfilt will generate the ordinals starting from ord.
The ordinals are generated along with the @ character as consistent with the
module definition (.DEF) file EXPORTS statement syntax.
For example, with the /o 1000 option specified, the output for a single name
would look something like this:
;ILinkedSequenceImpl::isConsistent() const
isConsistent__19ILinkedSequenceImplCFv @1000
If you do not specify the /o option, the default is not to generate ordinals
after each demangled name.
For more information on using module definition files, refer to the IBM* OS/2*
Developer's Toolkit online Tools Reference for the LINK386 program.
ΓòÉΓòÉΓòÉ 3.3.1.7. NONAME Keyword ΓòÉΓòÉΓòÉ
Specify the /n option on the cppfilt command line to instruct cppfilt to
generate the NONAME keyword as consistent with the module definition (.DEF)
file EXPORTS statement syntax. The NONAME keyword indicates that the exported
names should be referenced by their ordinals, and not by their names.
Note: You should also specify the /n together with the /o option to generate
ordinals.
For example, if you specify the /n /o 1000 options, the output for a single
name would look something like this:
;ILinkedSequenceImpl::isConsistent() const
isConsistent__19ILinkedSequenceImplCFv @1000 NONAME
For more information on using module definition files, refer to the IBM* OS/2*
Developer's Toolkit online Tools Reference for the LINK386 linker.
ΓòÉΓòÉΓòÉ 3.3.1.8. Help ΓòÉΓòÉΓòÉ
ΓòÉΓòÉΓòÉ 3.3.1.9. Do Not Display Logo ΓòÉΓòÉΓòÉ
ΓòÉΓòÉΓòÉ 3.3.2. .OBJ and .LIB Files ΓòÉΓòÉΓòÉ
The filenames that you specify after the cppfilt /B Binary mode command must be
object (.OBJ) or library (.LIB) files. They must be present in the current
directory, unless their paths are specified. cppfilt will also search for
library files along the paths specified in the LIB environment variable if the
files are not found in the current directory.
Input cannot be read from stdin in Binary mode. You must specify object or
library filenames for input.
All output is sent to stdout.
ΓòÉΓòÉΓòÉ 3.3.3. Output in Binary Mode ΓòÉΓòÉΓòÉ
cppfilt output in Binary mode lists any libraries and any object files within
each library. If you specify the /X, /R, and /P options, the exported,
referenced, and public symbols are also listed for each object file.
For example, the command
cppfilt /B /P /O 1000 /N c:\ibmcpp\lib\dde4cc.lib
would produce the following output for a library file called DDE4CC.LIB:
;From library: c:\ibmcpp\lib\dde4cc.lib
;From object file: C:\ibmcpp\src\IILNSEQ.C
;PUBDEFs (Symbols available from object file):
;ILinkedSequenceImpl::setToPrevious(ILinkedSequenceImpl::Node*&) const
setToPrevious__19ILinkedSequenceImplCFRPQ2_19ILinkedSequenceImpl4Node @1000 NONAME
;ILinkedSequenceImpl::allElementsDo(void*,void*) const
allElementsDo__19ILinkedSequenceImplCFPvT1 @1001 NONAME
;ILinkedSequenceImpl::isConsistent() const
isConsistent__19ILinkedSequenceImplCFv @1002 NONAME
;ILinkedSequenceImpl::setToNext(ILinkedSequenceImpl::Node*&) const
setToNext__19ILinkedSequenceImplCFRPQ2_19ILinkedSequenceImpl4Node @1003 NONAME
;ILinkedSequenceImpl::addAsNext(ILinkedSequenceImpl::Node*,ILinkedSequenceImpl::Node*)
addAsNext__19ILinkedSequenceImplFPQ2_19ILinkedSequenceImpl4NodeT1 @1004 NONAME
;From object file: C:\ibmcpp\src\IITBSEQ.C
;PUBDEFs (Symbols available from object file):
;ITabularSequenceImpl::setToPrevious(ITabularSequenceImpl::Cursor&) const
setToPrevious__20ITabularSequenceImplCFRQ2_20ITabularSequenceImpl6Cursor @1034 NONAME
;ITabularSequenceImpl::allElementsDo(void*)
allElementsDo__20ITabularSequenceImplFPv @1035 NONAME
;ITabularSequenceImpl::removeAll(void*,void*)
removeAll__20ITabularSequenceImplFPvT1 @1036 NONAME
;ITabularSequenceImpl::addAllFrom(const ITabularSequenceImpl&)
addAllFrom__20ITabularSequenceImplFRC20ITabularSequenceImpl @1037 NONAME
;From object file: IIAVLKSS.C
;PUBDEFs (Symbols available from object file):
;IAvlKeySortedSetImpl::allElementsDo(void*,void*) const
allElementsDo__20IAvlKeySortedSetImplCFPvT1 @1080 NONAME
;IAvlKeySortedSetImpl::isFirst(const IAvlKeySortedSetImpl::Node*) const
isFirst__20IAvlKeySortedSetImplCFPCQ2_20IAvlKeySortedSetImpl4Node @1081 NONAME
;IAvlKeySortedSetImpl::setToPosition(unsigned long,IAvlKeySortedSetImpl::Node*&) const
setToPosition__20IAvlKeySortedSetImplCFUlRPQ2_20IAvlKeySortedSetImpl4Node @1082 NONAME
;IAvlKeySortedSetImpl::locateOrAddElementWithKey(const void*)
locateOrAddElementWithKey__20IAvlKeySortedSetImplFPCv @1083 NONAME
Note: This is only a partial listing of the actual output.
ΓòÉΓòÉΓòÉ 4. ------------------------------------------------------------------------------ ΓòÉΓòÉΓòÉ
ΓòÉΓòÉΓòÉ 5. Renaming Dynamic Link Libraries with DLLRNAME ΓòÉΓòÉΓòÉ
If your application uses the dynamic link libraries (DLLs) provided with C/C++
Tools, you would violate the C/C++ Tools licensing agreement if you shipped
your application with the C/C++ Tools library DLLs without first renaming the
DLLs.
The DLL rename utility, dllrname, allows you to build your application using
the library DLLs provided with C/C++ Tools, and then rename the library DLLs so
they can be shipped with your application without violating the C/C++ Tools
licence agreement.
ΓòÉΓòÉΓòÉ 5.1. Using the DLLRNAME Utility ΓòÉΓòÉΓòÉ
To use the DLL rename utility, build your application using the import
libraries provided with C/C++ Tools. Then, before you ship your application:
1. Copy the C/C++ Tools DLLs that your application uses into a working
directory.
2. Run the DLL rename utility, dllrname, against your executable files and
your working copies of the C/C++ Tools DLLs. The utility will rename the
DLLs as well as all internal names that need to be changed as a result.
ΓòÉΓòÉΓòÉ 5.2. Syntax of the DLLRNAME Utility ΓòÉΓòÉΓòÉ
The syntax for the dllrname command is:
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
ΓöÇΓöÇdllrnameΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼Γö┤ΓöÇΓöÇ
ΓööΓöÇModule-nameΓöÇΓöÿ
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
ΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼Γö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ
ΓööΓöÇOldname=NewnameΓöÇΓöÿ
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
ΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö¼ΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇ
ΓööΓöÇ/OptionΓöÇΓöÿ
ΓòÉΓòÉΓòÉ 5.2.1. Module Names ΓòÉΓòÉΓòÉ
The list of module names includes the C/C++ Tools library DLLs your application
uses, along with the EXEs and DLLs that reference them. They must be present in
the current directory, unless their paths are specified.
Note: It is important that you include all the modules in your application in
this list, since the names by which the modules reference the C/C++
Tools library DLLs must also be changed in the modules themselves.
ΓòÉΓòÉΓòÉ 5.2.2. Name Changes ΓòÉΓòÉΓòÉ
You specify the list of the name changes to be made by indicating
Oldname=Newname on the dllrname command line.
Oldname is the name of the C/C++ Tools library DLL as it was shipped from IBM*.
Newname is the name under which you will be shipping the C/C++ Tools library
DLL with your application.
Note: The dllrname utility requires that Oldname and Newname have the same
number of characters.
For example, to rename the C/C++ Tools library DLL, DDE4SBS.DLL to MYLIBRY.DLL,
specify the following on the dllrname command line:
DDE4SBS=MYLIBRY
ΓòÉΓòÉΓòÉ 5.2.3. DLLRNAME Options ΓòÉΓòÉΓòÉ
The following options control the operation of the dllrname utility:
/H or /?
/N
/Q
/R
Note: You can specify options using the slash form (/R) or the dash form (-R).
ΓòÉΓòÉΓòÉ 5.2.3.1. Help ΓòÉΓòÉΓòÉ
Specify the /H or /? option on the dllrname command line to see a short online
help on the dllrname command syntax and options.
If you do not specify this option, the default is not to display any online
help.
ΓòÉΓòÉΓòÉ 5.2.3.2. Do Not Rename DLL ΓòÉΓòÉΓòÉ
Specify the /N option on the dllrname command line to instruct the dllrname
utility not to rename any DLLs that appear in both the modules list and the
list of name changes.
If you do not specify this option, the default is to rename any DLLs that
appear in both the modules list and the list of name changes.
ΓòÉΓòÉΓòÉ 5.2.3.3. Do Not Display Logo ΓòÉΓòÉΓòÉ
Specify the /Q option on the dllrname command line to suppress the display of
the logo and copyright notice for the dllrname utility.
If you do not specify this option, the default is to display the logo and
copyright notice.
ΓòÉΓòÉΓòÉ 5.2.3.4. Do Not Generate Report ΓòÉΓòÉΓòÉ
Specify the /R option on the dllrname command line to suppress the generation
of a report detailing the name changes.
If you do not specify this option, the default is to generate a report
detailing the name changes.
ΓòÉΓòÉΓòÉ 5.3. An Example ΓòÉΓòÉΓòÉ
If you compiled your application using the following command lines:
ICC /Gd+ /Ge- /FeA.DLL A.C B.C C.C D.C A.DEF
IMPLIB A.LIB A.DLL
ICC /Gd+ /FeE.EXE E.C F.C G.C H.C A.LIB
your application would be made up of the files A.DLL and E.EXE. Since you
specified the /Gd+ compile option, your application also requires the file
DDE4SBS.DLL from C/C++ Tools.
To obtain a renamed copy of DDE4SBS.DLL which you may ship with your
application, use the following set of commands:
REM Get a working copy of the C/C++ Tools library DLL
COPY D:\IBMC\LIB\DDE4SBS.DLL
REM Change all the names
DLLRNAME A.DLL E.EXE DDE4SBS=MYSBSLB
DLLRNAME DDE4BSBS.DLL DDE4SBS=MYSBSLB
These commands will change A.DLL and E.EXE so that they will now require
MYSBSLB.DLL instead of DDE4SBS.DLL. dllrname will also rename DDE4SBS.DLL to
MYSBSLB.DLL.
The following is the text of the report generated by the dllrname utility:
> DLLRNAME A.DLL E.EXE DDE4SBS.DLL DDE4SBS=MYSBSLB
Licensed Materials - Property of IBM
IBM C/C++ Tools Version 2.01 - DLL Rename Utility
(C) Copyright IBM Corp., 1993, All Rights Reserved
US Government Users Restricted Rights - Use, duplication or disclosure
restricted by GSA ADP Schedule Contract with IBM Corp.
Processing file A.DLL.
1 external names in file A.DLL have been left unchanged.
2 names found in file A.DLL.
Executable name A has been left unchanged.
Imported DLL name DDE4SBS has been changed to MYSBSLB.
Processing file E.EXE.
2 external names in file E.EXE have been left unchanged.
3 names found in file E.EXE.
Executable name e has been left unchanged.
Imported DLL name A has been left unchanged.
Imported DLL name DDE4SBS has been changed to MYSBSLB.
Processing file dde4sbs.dll.
5 external names in file DDE4SBS.DLL have been left unchanged.
6 names found in file DDE4SBS.DLL.
Executable name DDE4SBS has been changed to MYSBSLB.
Imported DLL name DOSCALLS has been left unchanged.
Imported DLL name KBDCALLS has been left unchanged.
Imported DLL name VIOCALLS has been left unchanged.
Imported DLL name NLS has been left unchanged.
Imported DLL name MSG has been left unchanged.
File DDE4SBS.DLL has been renamed to MYSBSLB.DLL to match internal DLL name.
Complete. 0 error(s) detected.
ΓòÉΓòÉΓòÉ 5.4. How DLLRNAME Works ΓòÉΓòÉΓòÉ
All modules (EXEs and DLLs) that use other DLLs contain records specifying a
set of external file names that are needed to run the module. The dllrname
utility manipulates only these records; it does not modify your executable
code.
One of the external names specified in a module is the name of the module
itself. The name of module, as it appears in its own internal records, is
called its internal name. You specify this name with the NAME or LIBRARY record
in a DLL module definition (.DEF) file when you link the module. In the case
of an .EXE file, the loader essentially ignores the internal name. For a .DLL,
its internal name must match its filename otherwise the loader will refuse to
load the DLL. By default, dllrname will also change the filename of a DLL if
it changed its internal name.
The rest of the external names specified in a module are the names of the DLLs
to be loaded when the OS/2* loader loads the module. All of these DLLs must be
loaded for the OS/2 loader to successfully load the module. If you specify any
of these required DLLs for rename on the dllrname command line, dllrname also
changes the names of the required DLLs in the module itself.
The dllrname utility accepts 16- or 32-bit OS/2 protected mode executables. It
will not change DOS or Windows** executables, or any other file with a
different format.
ΓòÉΓòÉΓòÉ 5.5. What DLLRNAME Will Not Do ΓòÉΓòÉΓòÉ
The dllrname utility will not:
o Modify your executable code. This is important to remember if you use the
OS/2* API DosLoadModule() or the C/C++ Tools library call _loadmod() to load
a required DLL. You must modify your code to load the DLL using its modified
name.
o Modify DOS or Windows** executables.
o Change the name of a DLL to a name of different length.
ΓòÉΓòÉΓòÉ 5.6. Other Uses for DLLRNAME ΓòÉΓòÉΓòÉ
The dllrname utility can also be used to:
o Rename your own DLLs so that you can have multiple versions of your
application resident on the same machine for testing purposes.
o Obtain a report that lists all the DLLs used by a module. Simply invoke the
dllrname utility without specifying any DLL name changes.
ΓòÉΓòÉΓòÉ 6. ------------------------------------------------------------------------------ ΓòÉΓòÉΓòÉ
ΓòÉΓòÉΓòÉ 7. Creating and Maintaining Libraries with LIB ΓòÉΓòÉΓòÉ
The IBM* Library Manager (also referred to as LIB in this reference) lets you
create and maintain libraries of object code.
Library files are given the extension of .LIB (as in MYLIB.LIB). High
Performance File System (HPFS) files with names that end with ".LIB" (as in
MYLIBRARYFILE.NEW.LIB) are also supported.
LIB works with standard libraries and OS/2* import libraries. It does not work
with Dynamic Link Libraries (DLLs).
Use the LIB utility to:
o Create a new library
o Add, delete, or replace modules in a library
o Copy object modules in a library to object files
o List the contents of a library
ΓòÉΓòÉΓòÉ 7.1. Running LIB ΓòÉΓòÉΓòÉ
Run LIB by typing LIB at the operating system prompt.
Parameters can be supplied by one of three methods:
1. Enter them directly on the command line.
2. Respond to prompts.
3. Put them in a text file called a response file and specify the file name
after the LIB command.
To enter more commands than can be conveniently entered on one line, type an
ampersand (&) at the end of the line and press Enter to extend the command
field to a new line. The ampersand can be used with all three input methods.
You can press Ctrl+C or Ctrl+Break at any time during a LIB run to return to
the operating system. Interrupting LIB before completion restores the library
from the backup.
Note:
o When started, LIB makes a backup copy of the original library in case it is
interrupted or a mistake is made. Make sure you have enough disk space for
both your original library and the modified copy.
o The library must end with the extension .LIB. If an extension is not
specified, the default extension, .LIB, will be appended. HPFS file names
are supported. Hence, MYLIBRARYNAME.NEW.LIB is still a valid library. Note
that this implies that MYLIBRARYNAME.NEW refers to MYLIBRARYNAME.NEW.LIB.
o If you enter an input library name and follow it immediately with a semicolon
(;), LIB performs a consistency check on the library and takes no other
action.
ΓòÉΓòÉΓòÉ 7.1.1. Using the Command Line ΓòÉΓòÉΓòÉ
You can specify all the input LIB needs on the command line. The syntax of the
command line is:
LIB [options] inlibrary [commands] [[,listfile] [, outlibrary]] [;]
inlibrary The input library to be modified.
options Options that affect the way LIB runs.
commands Commands used to add, delete, replace, copy, and move modules
within the library.
listfile The name for a listing file. If you don't specify a name, no
file is created.
outlibrary The output library created from the input library. If you
don't specify an output library, your input library is
replaced with the modified version (see below).
Commas are used to separate commands and options. The semicolon (;) is used to
mark the end of the command line.
ΓòÉΓòÉΓòÉ 7.1.2. Using LIB Prompts ΓòÉΓòÉΓòÉ
If you don't provide input to LIB on the command line, LIB prompts you for the
information it needs by displaying the following messages, one at a time:
Prompt Enter
Library name Name of the input library to be modified.
Operations Commands to modify the library. If no operations are
specified, the input library is unchanged.
List file Name for a listing file If no listing file is specified, no
listing file is created.
Output library Name of the output library to be created from the input
library. If no output library is specified, LIB modifies the
input library.
Enter the same information that you would enter when using the LIB command
line.
Notes
o LIB waits for you to respond to each prompt before displaying the next
prompt. If you notice that you have entered an incorrect response to a
previous prompt, press Ctrl+C or Ctrl+Break to exit LIB and begin again.
o A file name must be entered at the Library name: prompt. To choose a default
response for any of the other prompts, press Enter. To choose default
responses for all remaining prompts, type a semicolon (;) and press Enter.
ΓòÉΓòÉΓòÉ 7.1.3. Using a LIB Response File ΓòÉΓòÉΓòÉ
To provide input to LIB with a response file, type:
LIB @responsefile;
The field responsefile is the name of a file containing the same information
that can be specified on the command line.
In a sense, a response file extends the command line to include everything in
the response file. To split input to LIB between the command line and a
response file, put part of your input on the command line and specify a
response file (preceding the response file name with the at sign (@)). The
response file name can be any valid OS/2* file. To use special characters such
as a space or the @ symbol, the filename must be enclosed in quotes.
LIB responds to input you place in a response file just as it does to input you
enter on a command line or after a prompt. Using a newline character in the
response file is the equivalent of pressing the Enter key after a LIB prompt.
A response file uses one text line for each prompt. To extend a LIB command to
multiple lines, end each line except the last with an ampersand (&). Responses
must appear in the same order as the prompts. If a response for one of the
prompts does not appear, the default is used.
Use a response file for:
o Complex and long commands you type frequently
o Strings of commands that exceed the limit for command line length.
ΓòÉΓòÉΓòÉ <hidden> Specifying LIB Parameters - Examples ΓòÉΓòÉΓòÉ
This panel shows you examples of each method for specifying parameters to LIB.
The operations shown in each example create a new library, NEWLIB.LIB, and its
listing file, NEWLIB.LST, from the existing MYLIB.LIB library. MYLIB.LIB is
unchanged, but NEWLIB.LIB has these changes:
o The contents are case-insensitive.
o The module TIM is deleted.
o The object file SIMON.OBJ is appended as an object module with the name
SIMON.
o The existing module KEHM is deleted and is replaced by a new KEHM which is
appended after SIMON.
o The module LAM is copied into an object file named LAM.OBJ.
Command Line Method
At the operating system prompt, enter the following two lines.
LIB /I MYLIB, SIMON-TIM-+KEHM &
*LAM, NEWLIB.LST, NEWLIB;
LIB Prompts Method
To have LIB prompt you for input, enter LIB with no parameters.
Library name: /I MYLIB
Operations: +SIMON-TIM-+KEHM &
Operations: *LAM
List file: NEWLIB.LST
Output library: NEWLIB
Response File Method
First, create a response file with the following contents.
/I MYLIB
+SIMON-TIM-+KEHM &
*LAM
NEWLIB.LST
NEWLIB
Then, assuming the name of the response file is response.fil, invoke LIB with:
LIB @RESPONSE.FIL;
Note that the lines in the response file match the entries you would have made
with the prompting method. Even the ampersand character (&), the continuation
character, is used in the same way.
ΓòÉΓòÉΓòÉ 7.2. Creating a New Library ΓòÉΓòÉΓòÉ
To create a new library file, specify the name of the library file you want to
create on the command line (or at the Library name: prompt when using LIB
prompts).
Note: A library file is automatically created if the library file name you
specify is immediately followed by a command, comma, or semicolon. In this
case, the prompt does not appear.
If the name you specify for the new library file already exists, LIB assumes
that you want to modify the existing file.
When you give the name of a file that does not currently exist, LIB displays
the following prompt:
Library does not exist. Create library? (y or n)
Type y to create the file; type n to terminate the LIB run. If you specified an
extension other than .LIB, the LIB utility will try to append the .LIB
extension to the entire file name. If a library name is not entered, LIB will
prompt you for a library name.
ΓòÉΓòÉΓòÉ 7.3. Modifying a Library ΓòÉΓòÉΓòÉ
You can use LIB to alter the contents of any object code library. For example,
if you work with high level language libraries, you may want to replace a
standard routine with your own version of the routine. You may also want to add
a new routine to the standard library so that your routine is available along
with the standard routines.
To modify an existing library file, specify the name of the library file you
want to modify on the LIB command line (or at the Library name: prompt when
using LIB prompts).
In the command field, enter one or more commands to add, delete, or replace
modules in the input library. Each command consists of a command character
immediately followed by the name of the module or object file. Note that the
Add command can be used to combine libraries as well as to add object files to
a library.
LIB creates a backup file of the library being modified if it already exists.
This backup file has the same name as the original library with a .BAK filename
extension.
Related information:
o Add command (+)
o Delete command (-)
o Replace command (-+)
ΓòÉΓòÉΓòÉ 7.4. Copying Object Modules to Object Files ΓòÉΓòÉΓòÉ
To copy a module from a library file to an object file, specify the name of the
library file on the LIB command line (or at the Library name: prompt when using
LIB prompts).
The command field on the command line allows you to move or copy modules.
Command Action
Copy (*) Copy the module to an object file and retain the module in the
library.
Move (-*) Copy the module to an object file and delete the module from the
library.
ΓòÉΓòÉΓòÉ 7.5. LIB Listings ΓòÉΓòÉΓòÉ
Listings give you the exact names of modules and public symbols, allowing you
to inspect the contents within a library.
To generate a listing file, enter the following on the command line (or at the
appropriate LIB prompt):
o The name of the library file in the inlibrary field
o The name of the listing file in the listfile field
When generating a listing file, the amount of detail can be varied. The level
of detail is specified with the
/Listlevel:n
option, with three different levels being available.
Level 1 is the default. It is the fastest to generate and contains the least
amount of information. All modules are listed in order of occurrence. For each
module, the level 1 option:
1. Shows the relative position and size of each module.
2. Lists all the public symbols defined in the module.
3. Lists all external symbols which must be resolved at link time.
Level 2 contains all the information of level 1. In addition, for each external
symbol, level 2 shows which module in the library contains the required public
symbols for resolving at link time. This can be overridden if a module is
linked to another module that already contains the symbol.
Level 3 contains all the information of level 2. In addition, Level 3 displays
the technical characteristics of the library. This option also contains a dump
of the extended dictionary. This is useful to determine which modules will be
implicitly linked in whenever a particular module is linked in.
Note: If you are using the IBM* C/C++ Tools product, definitions with mangled
names will be listed with the demangled form in brackets.
Sample Cross Reference Listing
LIB /LISTLEVEL:2 NEWLIB, NEWLIB.LST;
The command above directs LIB to place a listing of the contents of NEWLIB.LIB
into the file NEWLIB.LST. No path specification is given for NEWLIB.LST. By
default, the file created is put in the current directory.
ΓòÉΓòÉΓòÉ <hidden> Listing Example ΓòÉΓòÉΓòÉ
The syntax for generating a level 3 listing file is:
LIB /L:3 NEWLIB, NEWLIB.LST;
This command generates the a listing file called NEWLIB.LST containing the
following text:
IBM (R) Library Manager Version 2.00
Copyright (C) IBM Corporation 1991, 1992. All rights reserved.
Library name : D:\TEMP\NEWLIB.LIB
Listing detail level : 3
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
ΓöîΓöÇΓöñNumber of the module within the parent library. TheΓöé
Γöé Γöéfirst module number in the listing file is 00000. Γöé
Γöé ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
Γöé ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
Γöé ΓöéName of the module within the library.Γöé
Γöé ΓööΓöÇΓöÇΓö¼ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
00000:francis(OFFSET:0x00000010, SIZE:0x000004ca):
Γöé ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
Γöé ΓöéSize (in bytes) of the object module.Γöé
Γöé ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
ΓöéRelative offset (in bytes) of the module within the library.Γöé
ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
- Public Definitions:ΓöÇΓöñSymbols defined by the module. Γöé
francis ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
ΓöéSymbols defined in a differentΓöé
- External Definitions:ΓöÇΓöÇΓöÇΓöÇΓöñmodule within the library. Γöé
DosAllocMem ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
_ilog2
_critlib_except
_DosSelToFlat
_DosFlatToSel
00001:lam (OFFSET:0x000004e0, SIZE:0x000001d1):
- Public Definitions:
lam
- External Definitions:
francis <- 00000:francisΓöÇΓöÇΓöÇΓöÇΓöÉ
_critlib_except Γöé
_DosSelToFlat ΓöîΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓö┤ΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÉ
_DosFlatToSel ΓöéNumber and name of the module within the libraryΓöé
Γöéthat defines the corresponding public symbol. Γöé
ΓööΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÇΓöÿ
00002:hazlett (OFFSET:0x000006c0, SIZE:0x0000021a):
- Public Definitions:
hazlett
- External Definitions:
DosFreeMem
_critlib_except
_DosSelToFlat
_DosFlatToSel
_pBucketArr
00003:simon (OFFSET:0x000008e0, SIZE:0x00000428):
- Public Definitions:
simon
- External Definitions:
_ilog2
hazlett <- 00002:hazlett
francis <- 00000:francis
_critlib_except
_DosSelToFlat
_DosFlatToSel
_pBucketArr
00004:kehm (OFFSET:0x00000d10, SIZE:0x00000342):
- Public Definitions:
_kehm
- External Definitions:
DosFreeMem
_critlib_except
_DosSelToFlat
_DosFlatToSel
_pBucketArr
The following information describes the characteristics of the library.
Page size = 16
The Flags field determines case sensitivity. 0x1 indicates case sensitivity.
0x0 indicates no case sensitivity.
Flags = 0x0
Contains extended dictionary
Total number of modules = 5
Total bytes for modules = 4592
Total number of symbols in dictionary = 10
Maximum number of symbols in dictionary = 74
Total number of pages for the dictionary = 2
The following is the extended dictionary information. The number in parentheses
indicates the number of dependencies. It is followed by the list of modules
In this case, modules 0, 2, and 4 have no dependencies, module 1 is dependent
on module 0, and module 3 is dependent on modules 0 and 2.
======== Dependencies by Module ========
Module 00000 : (00000)
Module 00001 : (00001) 00000
Module 00002 : (00000)
Module 00003 : (00002) 00000 00002
Module 00004 : (00000)
ΓòÉΓòÉΓòÉ 7.6. LIB Commands ΓòÉΓòÉΓòÉ
LIB commands are used to manipulate modules in a library. A single LIB run can
use multiple commands in any order.
Each command consists of a one- or two-character command symbol immediately
followed by the name of the module or file that is the subject of the command.
For example,
+EFREM.OBJ
adds the EFREM.OBJ object file to a library as EFREM.
Command Action
[+] Adds an object file or library to a library
- Deletes a module from a library
-+ Replaces a module in a library
* Copies a module from a library to an object file
-* Moves a module (copies the module and then deletes it)
Notes
o If you want to enter more commands than can be conveniently entered on one
line, type an ampersand (&) and press Enter at the end of the line. This
extends the command field to the next line.
o When processing commands, LIB processes all copy commands first. LIB
processes the deletions next, and the additions last.
o LIB never makes changes to your input library while it runs; it copies the
library and makes changes to the copy. However, if you do not specify an
output library, LIB overwrites the input library with the modified copy at
the end of normal processing. See Using the LIB Command Line for more
information.
ΓòÉΓòÉΓòÉ 7.6.1. Add Command (+) ΓòÉΓòÉΓòÉ
Use the add command to add an object module or library to a library. The add
command is issued by using the plus (+) sign or by leaving a blank space.
Adding an Object Module to a Library
Type the name of the object file to be added immediately after the plus sign.
The .OBJ extension may be omitted.
LIB uses the base name of the object file as the name of the object module in
the library. For example, if the object file B:\CURSOR.OBJ is added to a
library file, the name of the corresponding object module is CURSOR.
Object modules are always added to the end of a library file.
Combining Two Libraries
Specify the name of the library file to be added, including the .LIB extension,
immediately after the plus sign (+). A copy of the contents of that library is
added to the library file being modified. If both libraries contain a module
with the same name, LIB ignores the second module with that name.
LIB adds the modules of the library to the end of the library being changed.
Note that the added library still exists as an independent library because LIB
copies the modules without deleting them.
Examples
LIB MYLIB +EFREM;
The command above adds the file EFREM.OBJ to the library MYLIB.LIB.
LIB NEWLIB +KAREN.LIB;
The command above adds the contents of the library KAREN.LIB to the library
NEWLIB.LIB. The library KAREN.LIB is unchanged after this command is executed.
ΓòÉΓòÉΓòÉ 7.6.2. Delete Command (-) ΓòÉΓòÉΓòÉ
Use the delete command (-) to delete an object module from a library. After the
minus sign, specify the name of the module to be deleted. Module names do not
have path names or extensions.
Example
LIB MYLIB -EFREM;
The command above deletes the module EFREM from the library MYLIB.LIB.
ΓòÉΓòÉΓòÉ 7.6.3. Replace Command (-+) ΓòÉΓòÉΓòÉ
Use the replace command (-+) to replace a module in a library. Following the
symbol, specify the name of the module to be replaced.
To replace a module, LIB performs the following steps:
1. Deletes the existing module
2. Searches the current directory for the .OBJ file with the same file name as
the deleted module
3. Appends to the library a copy of the object file with the original module
name
Example
LIB MYLIB -+EFREM;
The command above replaces the module EFREM in the MYLIB.LIB library with the
contents of EFREM.OBJ from the current directory. The file EFREM.OBJ in the
current directory is not altered.
ΓòÉΓòÉΓòÉ 7.6.4. Copy Command (*) ΓòÉΓòÉΓòÉ
Use the copy command (*) to copy a module from the library into an object file
of the same name. The module remains in the library.
When LIB copies the module to an object file, it adds the .OBJ extension to the
module name and places the file in the current directory. If a file with this
name already exists, LIB overwrites the existing .OBJ file.
Example
LIB MYLIB *EFREM;
The command above copies the module EFREM from the MYLIB.LIB library to a file
called EFREM.OBJ in the current directory. The module EFREM in MYLIB.LIB is not
altered.
ΓòÉΓòÉΓòÉ 7.6.5. Move Command (-*) ΓòÉΓòÉΓòÉ
Use the move command (-*) to copy an object module from the library file to an
object file. The object module is then deleted from the library file. This
operation is equivalent to copying the module to an object file, then deleting
the module from the library.
Example
LIB MYLIB -*KEELING;
The command above moves the module KEELING from the MYLIB.LIB library to a file
called KEELING.OBJ in the current directory. Upon completion of this process,
MYLIB.LIB no longer contains the module KEELING.
ΓòÉΓòÉΓòÉ 7.7. Options ΓòÉΓòÉΓòÉ
Usage Notes:
o Option characters are not case sensitive; /H and /h are equivalent.
o The characters in brackets can be omitted; /H and /HELP are equivalent.
o Unless otherwise specified, most options and commands need only the first
letter of their names to be used.
The following is a summary of LIB options:
Option Action
/? or ? or /H[ELP] Display Help
/I[GNORECASE] Turn case sensitivity off
/NOE[XTDICTIONARY] Disable generation of extended dictionary
/NOI[GNORECASE] Turn case sensitivity on
/NOL[OGO] Suppress LIB banner
/Q[UIET] Suppress LIB banner
/P[AGESIZE] Set library page size
/L[ISTLEVEL] List current contents of library
ΓòÉΓòÉΓòÉ 7.7.1. Turn Case Sensitivity Off ΓòÉΓòÉΓòÉ
Turn Case Sensitivity Off (/I)
Syntax: /I[GNORECASE]
Purpose: Turns off case sensitivity for symbols
By default, case sensitivity is off. Use this option when you are combining a
library that was created with case sensitivity on (using the /NOI option) with
others that are not case sensitive. The resulting library is not case
sensitive.
ΓòÉΓòÉΓòÉ 7.7.2. Turn Case Sensitivity On ΓòÉΓòÉΓòÉ
Turn Case Sensitivity On (/NOI)
Syntax: /NOI[GNORECASE]
Purpose: Turns on case sensitivity
By default, case sensitivity is off (/I option). Using this option allows
symbols that differ only in case, such as Sine and SINE, to be included as
separate symbols in the same library.
Note that when you create a library with the /NOI option, LIB marks the library
internally to indicate that /NOI is in effect. If you combine multiple
libraries, and any one of them is marked /NOI, then the output library is
marked /NOI.
ΓòÉΓòÉΓòÉ 7.7.3. Do Not Generate Extended Dictionary ΓòÉΓòÉΓòÉ
/NOE Option
Disable Generation of Extended Dictionary (/NOE)
Syntax: /NOE[XTDICTIONARY]
Purpose: Disables generation of extended dictionary
The extended dictionary is an optional part of the library that increases
linking speed. However, using an extended dictionary requires more memory. The
space reserved for the extended dictionary is limited to 64K, no more can be
allocated. If LIB reports an out-of-memory error, you may want to use this
option. As an alternative, you can split large libraries into smaller libraries
to use in linking.
ΓòÉΓòÉΓòÉ 7.7.4. Set Library Page Size ΓòÉΓòÉΓòÉ
Set Library Page Size (/P)
Syntax: /P[AGESIZE]: n
Purpose: Sets library page size
This option specifies the library page size of a new library or changes that of
an existing library. The new page size n must be an integer value representing
a power of 2 between the values 16 and 32,768.
A library's page size affects the alignment of modules stored in the library.
Modules are always aligned to start at a position that is a multiple of the
page size (in bytes) from the beginning of the file. The default page size for
a new library is 16 bytes. For an existing library, the default is its current
page size.
Because of LIB's indexing technique, the larger the page size, the more modules
a library can hold. Each module requires an average of n/2 bytes of storage
space. Therefore, you should use a small page size unless you need to put a
very large number of modules in a library.
Another consequence of LIB's indexing technique is that the page size limits
the size of the library file to n * 65,536. For example, the option /P:16
limits the size to 1 megabyte (16 * 65,536 bytes).
ΓòÉΓòÉΓòÉ 7.7.5. Display Help ΓòÉΓòÉΓòÉ
Display Help
Syntax: /H[ELP]
or
/?
or
?
Purpose: Displays help on LIB
A brief summary of LIB syntax is displayed.
ΓòÉΓòÉΓòÉ 7.7.6. Supress Banner ΓòÉΓòÉΓòÉ
Suppress LIB Banner
Syntax: /NOL[OGO] or /Q[UIET]
Purpose: Suppresses the LIB copyright notice.
This option suppresses the banner message when LIB is started. It can be used
in batch files.
ΓòÉΓòÉΓòÉ <hidden> Library ΓòÉΓòÉΓòÉ
A library is an organized collection of object code which contains functions
and data that are already assembled or compiled. Once an object file is
incorporated into a library, it becomes an object module.
Libraries are used to:
o Support high level languages. Most compilers include libraries to perform
standard operations, such as input/output and floating-point mathematics.
When your program refers to a library routine, the compiler and linker
combine the library routine with your program.
o Perform complex and specialized activities, such as database management or
advanced graphics. You can use your own libraries or specialized libraries
supplied by a vendor.
o Support your own work. If you have created routines that you use with a
variety of programs, you may want to consolidate these routines into a
library. You can then link to one library.
ΓòÉΓòÉΓòÉ <hidden> Output Library ΓòÉΓòÉΓòÉ
If you specify a file in outlibrary, LIB creates a new output file with the
modifications and leaves your input file intact. Otherwise, LIB replaces your
input file with the modified file. In the latter case, a backup of your
original input file is stored in the current directory with the file name
extension .BAK.
ΓòÉΓòÉΓòÉ <hidden> Object File ΓòÉΓòÉΓòÉ
An object file is produced by a compiler or assembler from one or more source
files. An object file has an extension of .OBJ (as in MYPROJ.OBJ). LIB also
supports HPFS file names that end with ".OBJ" (as in MYOBJECTFILE.NEW.OBJ).
ΓòÉΓòÉΓòÉ <hidden> Object Module ΓòÉΓòÉΓòÉ
An object module is a self-contained unit within a library of precompiled or
preassembled routines. When individual object files are combined into a single
library file, they become object modules.
In LIB, an object module is referred to by its name, without a file extension.
For example, assume that the object file KEELING.OBJ is inserted into a
library. It then becomes an object module and is simply referred to as
KEELING.
ΓòÉΓòÉΓòÉ 8. ------------------------------------------------------------------------------ ΓòÉΓòÉΓòÉ
ΓòÉΓòÉΓòÉ <hidden> ΓòÉΓòÉΓòÉ
Trademark of the IBM Corporation
ΓòÉΓòÉΓòÉ <hidden> ΓòÉΓòÉΓòÉ
Dynamic Link Library
ΓòÉΓòÉΓòÉ <hidden> ΓòÉΓòÉΓòÉ
Trademark of the Microsoft Corporation