home *** CD-ROM | disk | FTP | other *** search
/ High Voltage Shareware / high1.zip / high1 / DIR14 / FP_210.ZIP / PROBLEM.DOC < prev    next >
Text File  |  1993-07-07  |  1KB  |  29 lines

  1.                 Known problems with F-PROT
  2.  
  3. The following compatibility problems are known at the moment, and will be
  4. fixed as soon as possible.
  5.  
  6. VIRSTOP is not compatible with the Cyrix 486SLC processor because of a
  7. "bug" in the Cyrix chip - it is not 100% compatible with Intel processors.
  8.  
  9. VIRSTOP.EXE is not effective if run before a program which totally takes
  10. over the "Load-and-Execute" function.  This includes Novell Netware and
  11. PC-NFS, and as explained elsewhere, VIRSTOP should be run after those
  12. programs.  However, this also applies to DesqView - which means that
  13. VIRSTOP is not effective inside a DOS window in DesqView.
  14.  
  15. Occasionally, when using Novell Netware with VIRSTOP installed, and an
  16. attempt is made to send anything to a Laser printer over the network, from
  17. inside Excel or Word, the output may become garbled.  The reason for this
  18. is not known, but a few other TSR's are known to cause the same problem,
  19. so this may not be a F-PROT problem.  This is usually solved by using
  20. LPT1.OS2 instead of LPT1 as the printer port.
  21.  
  22. The following problem is not likely to go away in the near future:
  23.  
  24. F-PROT cannot be used on a single-floppy machine without a hard disk
  25. or network connections. This is because if the F-PROT is run from a
  26. diskette, the diskette may not be removed while the program is running, so