home *** CD-ROM | disk | FTP | other *** search
/ norge.freeshell.org (192.94.73.8) / 192.94.73.8.tar / 192.94.73.8 / pub / computers / pdp10 / tops-10 / gt40.hlp < prev    next >
INI File  |  1995-04-05  |  3KB  |  84 lines

  1. [Help GT40]
  2.                 THE DEC GT40 AND OMNIGRAPH
  3.  
  4.         THE REFRESH-TYPE CRT DISPLAY CALLED THE GT40 HAS BEEN
  5. INCLUDED IN THE NIH OMNIGRAPH DISPLAY SYSTEM, AND OPERATES IN A
  6. MANNER SOMEWHERE BETWEEN THE DEC 340 AND A STORAGE TUBE CRT.
  7.  
  8.         SPECIFICALLY:
  9.  
  10. 1.   THE GT40 DOES NOT REQUIRE A HIGH (SECOND) SEGMENT.
  11.  
  12. 2.   POST/UNPOST/APPEND/KILL ARE IMMEDIATE UNLIKE STORAGE TUBES.
  13.  
  14. 3.   THERE ARE 8 LEVELS OF INTENSITY, BUT ONLY ONE CHAR SIZE.
  15.  
  16. 4.   THERE ARE 4 VECTOR-TYPES, ITALICS, AND HARDWARE BLINK!!!
  17.      THIS IS IMPLEMENTED IN OMNIGRAPH VIA A NEW ROUTINE: DSTAT(I)
  18.      WHERE THE USER CAN CONTROL EACH FEATURE INDEPENDENTLY
  19.      BY PASSING A SIGNED INTEGER I EQUAL TO THE SUMMATION OF
  20.      VARIOUS INTEGERS CHOSEN FROM THE FOLLOWING:
  21.      IF YOU WISH TO USE A LINE TYPE OTHER THAN THE
  22.      DEFAULT (SOLID LINES),
  23.         I=1   SET SOLID-LINE TYPE
  24.         I=2   SET SHORT-VECTOR TYPE
  25.         I=3   SET LONG-DASH TYPE
  26.         I=4   SET DOT-DASH TYPE
  27.      PLUS, IF YOU WISH TO START HARDWARE BLINK AND/OR ITALICS,
  28.         I=8   SET BLINK (APPLIES TO TEXT, POINTS AND LINES)
  29.         I=16  SET ITALICS
  30.      HENCE, A POSITIVE VALUE OF, SAY, 11 (8+3) MEANS BLINK AND LINE
  31.      TYPE=LONG-DASH.  SIMILARLY, 28 WOULD IMPLY ITALICS, BLINKING
  32.      AND DOT-DASH LINES.
  33.      YOU CAN RESET TO THE DEFAULT STATUS (NO ITALICS, NO BLINKING,
  34.      AND SOLID LINES) BY PASSING A VALUE OF 0.
  35.      FINALLY, YOU CAN RESET AN INDIVIDUAL FEATURE OR SOME COMBINATIONS
  36.      BY PASSING A NEGATIVE VALUE.  FOR EXAMPLE, A VALUE OF -8
  37.      WOULD RESET TO NO BLINKING WITHOUT AFFECTING ITALICS OR LINE
  38.      TYPE.  HOWEVER, SINCE THE CHOICE OF LINE TYPES IS NOT BINARY,
  39.      AN INTEGER VALUE IMPLYING -1 THROUGH -4 WILL CAUSE THE LINE TYPE
  40.      TO BE RESET TO SOLID (E.G., -17 IMPLIES NO MORE ITALICS AND 
  41.      RESET TO SOLID).
  42.      FINALLY NOTE THAT DSTAT IS A NO-OP ON OTHER DISPLAYS.
  43.  
  44. 5.   THE GT40 HAS A CAPACITY FOR 1400 INCHES OF VECTORS (MOVES
  45.      AND DRAWS) FLICKER-FREE.  THIS IS CONSIDERABLY GREATER THAN
  46.      THAT OF THE DEC 340.  HOWEVER, THE GT40'S CORE PERMITS UP 
  47.      TO 7000 SHORT VECTORS (LESS THAN A HALF INCH) OR 3500 LONG
  48.      VECTORS, SO THAT SEVERE FLICKER IS POSSIBLE.
  49.  
  50. 6.   THE GT40 IS INITIATED BY THE FOLLOWING PROCEDURE:
  51.         POWER ON
  52.         SET SWITCHES 15,14,13,11, AND 10 TO THE UP POSITION
  53.         DEPRESS THE HALT SWITCH, THEN THE LOAD ADDRESS SWITCH,
  54.         RAISE THE HALT SWITCH BACK TO THE ENABLE POSITION,
  55.         RESET SWITCHES 15,14,13,11,10 TO THE DOWN POSITION,
  56.         AND FINALLY HIT THE START SWITCH.
  57.         TYPE ^C (YOU MAY HAVE TO BE PATIENT UNTIL SCREEN WARMS UP)
  58.         LOG IN AS USUAL AND WHEN IN MONITOR STATE, TYPE BOOTGT<CR>
  59.         WHEH "FILE:" IS PRINTED, TYPE   SYS:GTOMNI<CR>
  60.         DON'T TYPE ANYTHING ELSE!!!!
  61.         WHEN YOU SEE THE CURSOR IN THE UPPER LEFT CORNER AND THE
  62.         WORD "GTOMNI" IN THE UPPER RIGHT, YOU CAN USE THE DEVICE AS
  63.         ANY OTHER TERMINAL.
  64.  
  65. 7.    IF STRANGE OCCURRENCES ARISE, YOU CAN FORCE A MANUAL
  66.       RESET OF THE GT40 MONITOR BY MOMENTARILY RAISING SWITCH 15.
  67.       THIS IS USEFUL IN DELETING ALL PICTURES INADVERTENTLY LEFT
  68.       WITHIN THE GT40 CORE.
  69.  
  70. 8.    IN THE OMNIGRAPH CALL TO DINI, REFER TO <GT40> OR <5>.
  71.  
  72. 9.    YOU MAY "TYPE AHEAD" WITH THIS GT40 MONITOR.
  73.  
  74.  
  75.  
  76. FOR A DESCRIPTION OF THE GT40 MONITOR "GTOMNI," TYPE
  77. "HELP GTOMNI".
  78.  
  79.  
  80. [End of GT40.HLP]
  81.  
  82. .KJOB
  83. .
  84.