- **** ASC and ASCQ Assignments (byte 12 and 13) ****
- **** ****
- **** from ****
- **** ****
- **** draft proposed ****
- **** American National Standard ****
- **** for information systems - ****
- **** ****
- **** SMALL COMPUTER SYSTEM INTERFACE - 2 ****
- **** (SCSI-2) ****
- **** ****
- **** March 9, 1990 ****
- **** ****
- ***************************************************
-
-
- 00 00 No additional sense information
- 00 01 Filemark detected
- 00 02 End-of-partition/medium detected
- 00 03 Setmark detected
- 00 04 Beginning-of-partition/medium detected
- 00 05 End-of-data detected
- 00 06 I/O process terminated
- 00 11 Audio play operation in progress
- 00 12 Audio play operation paused
- 00 13 Audio play operation successfully completed
- 00 14 Audio play operation stopped due to error
- 00 15 No current audio status to return
- 01 00 No index/sector signal
- 02 00 No seek complete
- 03 00 Peripheral device write fault
- 03 01 No write current
- 03 02 Excessive write errors
- 04 00 Logical unit not ready, cause not reportable
- 04 01 Logical unit is in process of becoming ready
- 04 02 Logical unit not ready, initializing command required
- 04 03 Logical unit not ready, manual intervention required
- 04 04 Logical unit not ready, format in progress
- 05 00 Logical unit does not respond to selection
- 06 00 No reference position found
- 07 00 Multiple peripheral devices selected
- 08 00 Logical unit communication failure
- 08 01 Logical unit communication time-out
- 08 02 Logical unit communication parity error
- 09 00 Track following error
- 09 01 Tracking servo failure
- 09 02 Focus servo failure
- 09 03 Spindle servo failure
- 0A 00 Error log overflow
- 0B 00
- 0C 00 Write error
- 0C 01 Write error recovered with auto reallocation
- 0C 02 Write error - auto reallocation failed
- 0D 00
- 0E 00
- 0F 00
- 10 00 ID CRC or ECC error
- 11 00 Unrecovered read error
- 11 01 Read retries exhausted
- 11 02 Error too long to correct
- 11 03 Multiple read errors
- 11 04 Unrecovered read error - auto reallocate failed
- 11 05 L-EC uncorrectable error
- 11 06 CIRC unrecovered error
- 11 07 Data resychronization error
- 11 08 Incomplete block read
- 11 09 No gap found
- 11 0A Miscorrected error
- 11 0B Unrecovered read error - recommend reassignment
- 11 0C Unrecovered read error - recommend rewrite the data
- 12 00 Address mark not found for id field
- 13 00 Address mark not found for data field
- 14 00 Recorded entity not found
- 14 01 Record not found
- 14 02 Filemark or setmark not found
- 14 03 End-of-data not found
- 14 04 Block sequence error
- 15 00 Random positioning error
- 15 01 Mechanical positioning error
- 15 02 Positioning error detected by read of medium
- 16 00 Data synchronization mark error
- 17 00 Recovered data with no error correction applied
- 17 01 Recovered data with retries
- 17 02 Recovered data with positive head offset
- 17 03 Recovered data with negative head offset
- 17 04 Recovered data with retries and/or CIRC applied
- 17 05 Recovered data using previous sector ID
- 17 06 Recovered data without ECC - data auto-reallocated
- 17 07 Recovered data without ECC - recommend reassignment
- 18 00 Recovered data with error correction applied
- 18 01 Recovered data with error correction and retries applied
- 18 02 Recovered data - data auto-reallocated
- 18 03 Recovered data with CIRC
- 18 04 Recovered data with LEC
- 18 05 Recovered data - recommend reassignment
- 19 00 Defect list error
- 19 01 Defect list not available
- 19 02 Defect list error in primary list
- 19 03 Defect list error in grown list
- 1A 00 Parameter list length error
- 1B 00 Synchronous data transfer error
- 1C 00 Defect list not found
- 1C 01 Primary defect list not found
- 1C 02 Grown defect list not found
- 1D 00 Miscompare during verify operation
- 1E 00 Recovered id with ECC correction
- 1F 00
- 20 00 Invalid command operation code
- 21 00 Logical block address out of range
- 21 01 Invalid element address
- 22 00 Illegal function (should use 20 00, 24 00, or 26 00)
- 23 00
- 24 00 Invalid field in CDB
- 25 00 Logical unit not supported
- 26 00 Invalid field in parameter list
- 26 01 Parameter not supported
- 26 02 Parameter value invalid
- 26 03 Threshold parameters not supported
- 27 00 Write protected
- 28 00 Not ready to ready transition (medium may have changed)
- 28 01 Import or export element accessed
- 29 00 Power on, reset, or bus device reset occurred
- 2A 00 Parameters changed
- 2A 01 Mode parameters changed
- 2A 02 Log parameters changed
- 2B 00 Copy cannot execute since host cannot disconnect
- 2C 00 Command sequence error
- 2C 01 Too many windows specified
- 2C 02 Invalid combination of windows specified
- 2D 00 Overwrite error on update in place
- 2E 00
- 2F 00 Commands cleared by another initiator
- 30 00 Incompatible medium installed
- 30 01 Cannot read medium - unknown format
- 30 02 Cannot read medium - incompatible format
- 30 03 Cleaning cartridge installed
- 31 00 Medium format corrupted
- 31 01 Format command failed
- 32 00 No defect spare location available
- 32 01 Defect list update failure
- 33 00 Tape length error
- 34 00
- 35 00
- 36 00 Ribbon, ink, or toner failure
- 37 00 Rounded parameter
- 38 00
- 39 00 Saving parameters not supported
- 3A 00 Medium not present
- 3B 00 Sequential positioning error
- 3B 01 Tape position error at beginning-of-medium
- 3B 02 Tape position error at end-of-medium
- 3B 03 Tape or electronic vertical forms unit not ready
- 3B 04 Slew failure
- 3B 05 Paper jam
- 3B 06 Failed to sense top-of-form
- 3B 07 Failed to sense bottom-of-form
- 3B 08 Reposition error
- 3B 09 Read past end of medium
- 3B 0A Read past beginning of medium
- 3B 0B Position past end of medium
- 3B 0C Position past beginning of medium
- 3B 0D Medium destination element full
- 3B 0E Medium source element empty
- 3C 00
- 3D 00 Invalid bits in identify message
- 3E 00 Logical unit has not self-configured yet
- 3F 00 Target operating conditions have changed
- 3F 01 Microcode has been changed
- 3F 02 Changed operating definition
- 3F 03 Inquiry data has changed
- 40 00 RAM failure (should use 40 NN)
- 40 NN Diagnostic failure on component NN (80H-FFH)
- 41 00 Data path failure (should use 40 NN)
- 42 00 Power-on or self-test failure (should use 40 NN)
- 43 00 Message error
- 44 00 Internal target failure
- 45 00 Select or reselect failure
- 46 00 Unsuccessful soft reset
- 47 00 SCSI parity error
- 48 00 Initiator detected error message received
- 49 00 Invalid message error
- 4A 00 Command phase error
- 4B 00 Data phase error
- 4C 00 Logical unit failed self-configuration
- 4D 00
- 4E 00 Overlapped commands attempted
- 4F 00
- 50 00 Write append error
- 50 01 Write append position error
- 50 02 Position error related to timing
- 51 00 Erase failure
- 52 00 Cartridge fault
- 53 00 Media load or eject failed
- 53 01 Unload tape failure
- 53 02 Medium removal prevented
- 54 00 SCSI to host system interface failure
- 55 00 System resource failure
- 56 00
- 57 00 Unable to recover table-of-contents
- 58 00 Generation does not exist
- 59 00 Updated block read
- 5A 00 Operator request or state change input (unspecified)
- 5A 01 Operator medium removal request
- 5A 02 Operator selected write protect
- 5A 03 Operator selected write permit
- 5B 00 LOG exception
- 5B 01 Threshold condition met
- 5B 02 LOG counter at maximum
- 5B 03 LOG list codes exhausted
- 5C 00 RPL status change
- 5C 01 Spindles synchronized
- 5C 02 Spindles not synchronized
- 5D 00
- 5E 00
- 5F 00
- 60 00 Lamp failure
- 61 00 Video acquisition error
- 61 01 Unable to acquire video
- 61 02 Out of focus
- 62 00 Scan head positioning error
- 63 00 End of user area encountered on this track
- 64 00 Illegal mode for this track
- 65 00
- 66 00
- 67 00
- 68 00
- 69 00
- 6A 00
- 6B 00
- 6C 00
- 6D 00
- 6E 00
- 6F 00
- 70 00
- 71 00
- 72 00
- 73 00
- 74 00
- 75 00
- 76 00
- 77 00
- 78 00
- 79 00
- 7A 00
- 7B 00
- 7C 00
- 7D 00
- 7E 00
- 7F 00
-