The two drive sizes do not match...drive size on the new drive will be changed

        Occurs on:  SFT II and TTS.

        Meaning:  This error message indicates that the REMIRROR console
                  command was used to attempt to remirror a drive and
                  the new mirror drive was set up for a different number
                  of logical blocks than the original active drive.  The
                  number of logical blocks on the drive is found by
                  subtracting the number of blocks used for redirection
                  from the total number of blocks on the drive.  This is
                  not a fatal error.

        Cause:  This error could be caused by invalid information
                written on either or both of the mirrored drives.  It
                may also be caused by physically exchanging one of the
                drives with another drive that has previously been
                mirrored under NetWare.

        Solution:  No action is necessary.  The remirror process will
                   automatically adjust the number of logical blocks and
                   the number of disk redirection blocks on the new
                   mirror drive to match the sizes found on the original
                   active drive.