Invalid configuration in CONFIG.UPS.

        Occurs on:  SFT II and TTS.

        Meaning:  This message indicates that as the file server was
                  booting, it attempted to use the information stored in
                  the file CONFIG.UPS to set up UPS monitoring and found
                  that it was invalid.  The CONFIG.UPS file is a text
                  file that contains parameters used by the UPS
                  monitoring function.  Although this is not a fatal
                  error, the UPS monitoring function will be disabled.

        Cause:  The CONFIG.UPS file contains invalid information.

        Solution:  If UPS monitoring is not desired, erase the
                   CONFIG.UPS file found in the directory SYS:SYSTEM on
                   the file server.  Otherwise, modify the CONFIG.UPS
                   file so that the parameters are correct, and reboot
                   the file server.