home *** CD-ROM | disk | FTP | other *** search
/ The Pier Shareware 6 / The_Pier_Shareware_Number_6_(The_Pier_Exchange)_(1995).iso / 031 / panel21.zip / PANEL.DOC < prev    next >
Text File  |  1994-08-27  |  38KB  |  1,113 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6.                     ELECTRICAL DESIGN SOFTWARE        
  7.  
  8.                 PANEL Version 2.1  Documentation   
  9.  
  10.           (c) Copyright 1994 Electrical Design Software 
  11.   
  12.              Licensed Material. All Rights Reserved.    
  13.  
  14.  
  15.  
  16.  
  17.                ▀▀▀▀▀▀▀▀▀▀  ▀▀▀▀▀▀▀▀       ▀▀▀▀▀▀            
  18.                 ▀▀▀    ▀▀   ▀▀▀    ▀     ▀▀    ▀▀           
  19.                 ▀▀▀     ▀   ▀▀▀     ▀   ▀▀      ▀           
  20.                 ▀▀▀         ▀▀▀     ▀▀  ▀▀                  
  21.                 ▀▀▀  ▀      ▀▀▀     ▀▀  ▀▀▀                 
  22.                 ▀▀▀  ▀      ▀▀▀     ▀▀   ▀▀▀                
  23.                 ▀▀▀▀▀▀      ▀▀▀     ▀▀     ▀▀▀              
  24.                 ▀▀▀  ▀      ▀▀▀     ▀▀       ▀▀▀            
  25.                 ▀▀▀  ▀      ▀▀▀     ▀▀        ▀▀▀           
  26.                 ▀▀▀         ▀▀▀     ▀▀         ▀▀           
  27.                 ▀▀▀     ▀   ▀▀▀     ▀   ▀      ▀▀           
  28.                 ▀▀▀    ▀▀   ▀▀▀    ▀    ▀▀    ▀▀            
  29.                ▀▀▀▀▀▀▀▀▀▀  ▀▀▀▀▀▀▀▀      ▀▀▀▀▀▀             
  30.  
  31.  
  32.  
  33.  
  34.                  ELECTRICAL DESIGN SOFTWARE 
  35.               12 Vassar Drive Pelham, NH 03076      
  36.  
  37.                 Phone or Fax: (603) 893-9008 
  38.  
  39.  
  40.  
  41.  
  42.  
  43.  
  44.  
  45.  
  46.  
  47.  
  48.  
  49.  
  50.  
  51.  
  52.  
  53.  
  54. Copyright (c) 1994  All Rights Reserved 
  55. PANEL 2.1  From Electrical Design Software
  56.  
  57.  
  58.  
  59. TABLE OF CONTENTS                                          PAGE
  60. ~~~~~~~~~~~~~~~~~                                          ~~~~
  61. Introduction ............................................... 1
  62.  
  63. Definition of Shareware .................................... 1
  64.  
  65. Disclaimer - Agreement ..................................... 2
  66.  
  67. What is PANEL Version 2.1................................... 3
  68.  
  69. Ordering PANEL 2.1 ......................................... 3
  70.  
  71. System requirements ........................................ 4
  72.  
  73. Files ...................................................... 4
  74.  
  75. Available Screen Modes...................................... 5
  76.  
  77. Printer Setup .............................................. 5
  78.  
  79. Controlling Windows......................................... 5
  80.  
  81. PANEL 2.1 Tutorial.......................................... 6-8
  82.  
  83. Other Printing Options ..................................... 8
  84.  
  85. How Records Are Displayed & Found........................... 8
  86.  
  87. Special Keys ............................................... 9 
  88.  
  89. Quick access keys from the main screen ..................... 10
  90.  
  91. Command buttons main work and names screen ................. 10
  92.  
  93. Help system ................................................ 11
  94.  
  95. General overview of the main menu selections................ 12-13
  96.  
  97. Each data entry field explained............................. 13-15
  98.  
  99. Data base subjects ......................................... 16
  100.  
  101. Maximum Field Length........................................ 17
  102.  
  103. Reporting - print or file .................................. 18
  104.  
  105. Support..................................................... 19
  106.        
  107. Copyright (c) 1994  All Rights Reserved 
  108. PANEL 2.1  From Electrical Design Software
  109.  
  110.  
  111.                     I N T R O D U C T I O N  
  112.                     ~~~~~~~~~~~~~~~~~~~~~~~   
  113.      Electrical Design Software is a New Hampshire based company 
  114. that was established in 1992.  Our organization's primary objective
  115. is to produce quality software, for the Electrical Industry, at a 
  116. reasonable price. 
  117.  
  118.      Panel 2.1 requires no special computer knowledge, and is 
  119. designed to accommodate both the amateur and professional user. 
  120. Context Sensitive Help Screens have been programmed into this
  121. application in order for you the, user, to continue working 
  122. quickly and efficiently.
  123.  
  124.      Most importantly, here at Electrical Design Software, YOUR 
  125. comments are considered essential, for the development of future
  126. software products.  With your input we can design programs that 
  127. will accommodate the electrical profession and other specialized 
  128. fields.
  129.  
  130.                   DEFINITION OF SHAREWARE
  131.                   ~~~~~~~~~~~~~~~~~~~~~~~
  132.      Shareware distribution gives users a chance to try software
  133. before buying it.  If you try a Shareware program and continue
  134. using it, you are expected to register. Individual programs differ
  135. on details -- some request registration while others require it, 
  136. some specify a maximum trial period.  With registration, you get 
  137. anything from the simple right to continue using the software to 
  138. an updated program with printed manual.
  139.  
  140.      Copyright laws apply to both Shareware and Commercial 
  141. software, and the copyright holder retains all rights, with a 
  142. few specific exceptions as stated below. Shareware authors are 
  143. accomplished programmers, just like commercial authors, and the
  144. programs are of comparable quality. (In both cases, there are 
  145. good programs and bad ones!) The main difference is in the method
  146. of distribution. The author specifically grants the right to copy
  147. and distribute the software, either to all and sundry or to a
  148. specific group. For example, some authors require written 
  149. permission before a commercial disk vendor may copy their
  150. Shareware.
  151.  
  152.      Shareware is a distribution method, not a type of software. 
  153. You should find software that suits your needs and pocketbook,
  154. whether it's commercial or Shareware. The Shareware system makes
  155. fitting your needs easier, because you can try before you buy.
  156. And because the overhead is low, prices are low also. Shareware
  157. has the ultimate money-back guarantee -- if you don't use the
  158. product, you don't pay for it.
  159.  
  160. Copyright (c) 1994  All Rights Reserved        Page 1 
  161. PANEL 2.1  From Electrical Design Software
  162.  
  163.  
  164.  
  165.  
  166.                    DISCLAIMER - AGREEMENT
  167.  
  168.      Users of Panel 2.1 must accept this disclaimer of warranty: 
  169. Panel 2.1 is supplied as is.  The author disclaims all warranties,
  170. expressed or implied, including, without limitation, the warranties
  171. of merchantability and of fitness for any purpose. The author 
  172. assumes no liability for damages, direct or consequential, which 
  173. may result from the use of Panel 2.1.
  174.  
  175.  
  176.      Panel 2.1 is a "Shareware Program" and is provided at no 
  177. charge to the user for evaluation.  Feel free to share it with 
  178. your friends, but please do not give it away altered or as part 
  179. of another system.  The essence of "user-supported" software is 
  180. to provide personal computer users with quality software without
  181. high prices, and yet to provide incentive for programmers to 
  182. continue to develop new products.  If you find this program 
  183. useful and find that you are using Panel 2.1 and continue to use
  184. Panel 2.1 after a reasonable trial period, you must make a 
  185. registration payment of *$44.00 to Electrical Design Software.  
  186. The *$44.00 registration fee will license one copy for use on 
  187. any one computer at any one time.  You must treat this software 
  188. just like a book. An example is that this software may be used 
  189. by any number of people and may be freely moved from one computer 
  190. location to another, so long as there is no possibility of it 
  191. being used at one location while it's being used at another. Just 
  192. as a book cannot be read by two different persons at the same time.
  193.  
  194.      Commercial users of Panel 2.1 must register and pay for their
  195. copies of Panel 2.1 within 30 days of first use or their license 
  196. is withdrawn. Site-License arrangements may be made by contacting 
  197. Electrical Design Software. 
  198.  
  199.      Anyone distributing Panel 2.1 for any kind of remuneration 
  200. must first contact Electrical Design Software at the address listed
  201. for authorization. This authorization will be automatically granted
  202. to distributors recognized by the (ASP) as adhering to its
  203. guidelines for shareware distributors, and such distributors may
  204. begin offering Panel 2.1 immediately (However Electrical Design
  205. Software must still be advised so that the distributor can be kept
  206. up-to-date with the latest version of Panel 2.1).
  207.  
  208. You are encouraged to pass a copy of Panel 2.1 along to your 
  209. friends for evaluation.  Please encourage them to register their 
  210. copy if they find that they can use it.  All registered users will
  211. receive a copy of the latest version of the Panel 2.1. 
  212.  
  213. Copyright (c) 1994  All Rights Reserved        Page 2 
  214. PANEL 2.1  From Electrical Design Software
  215.  
  216.         
  217.          WHAT IS PANEL - VERSION 2.1
  218.          ~~~~~~~~~~~~~~~~~~~~~~~~~~~
  219. Panel 2.1 is a complete database system that will store circuit
  220. directory and panel board information.  Custom circuit directories
  221. can be printed or sent to an ASCII file that can be edited with any
  222. word processor.  Reports are in a boxed style format or a plain
  223. format, with each report being a customized representation of the
  224. specific panel information. 
  225.  
  226. Panel is primarily designed for producing circuit directories to be
  227. inserted into the cover or display area of a panel or panel board
  228. assembly. Neat and orderly circuit directories lead to efficiency
  229. as well as upgrade the level of professionalism.  Other uses for
  230. panel is in the ordering of equipment in which a materials list for
  231. your equipment supplier could be produced.  For example a project
  232. that would require different panels, breaker sizes, style and etc
  233. could easily be printed and submitted for pricing.
  234.  
  235.  
  236. ORDERING  PANEL - VERSION 2.1
  237. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  238. You can order directly from Electrical Design Software by filling
  239. in the registration form and enclosing a check, OR
  240.  
  241. Credit card orders ONLY are available from Public (software)
  242. Library with your MC, Visa, AmEx, or Discover card by calling 
  243.  
  244. The item number when ordering Panel is 11263
  245.  
  246.   Voice phone (800)-242-4775              By fax (713)-524-6398 
  247. From overseas (713)-524-6394         By CompuServe to 71355.470
  248.  
  249. These numbers are for ORDERING only.  Electrical Design Software
  250. can NOT be reached at those numbers. To contact Electrical Design
  251. Software for information about dealer pricing, volume discounts,
  252. site or distribution licensing, the status of a product shipment,
  253. the latest version number, for technical information, or to discuss
  254. returns, call (603)-893-9008 or write Electrical Design Software,
  255. 12 Vassar Drive, Pelham, NH 03076. 
  256.  
  257. NEBS Compatible Forms from New England Business Service, Inc are
  258. available  with all Electrical Design Software programs .  The
  259. advantage of forms is to enhance the appearance of the printed
  260. reports.
  261.  
  262. To order forms ..................1-800-388-3810
  263. Multipurpose Form ...............9331 
  264. Mail code number ................11028 
  265.  
  266. Copyright (c) 1994  All Rights Reserved        Page 3 
  267. PANEL 2.1  From Electrical Design Software
  268.  
  269.                 SYSTEM REQUIREMENTS 
  270.                 ~~~~~~~~~~~~~~~~~~~ 
  271. PANEL 2.1 requires the following hardware and/or software to
  272. operate: 
  273.  
  274. 1.  450K memory - 286 or higher CPU. 
  275.  
  276. 2.  IBM(R) PC/XT/AT or true "compatible" running MS-DOS or PC-DOS 
  277.     Operating System version 3.1 or higher. 
  278.  
  279. 3.  One high-density floppy-disk drive or a hard disk drive (hard 
  280.     disk recommended) 
  281.  
  282. 4.  An EGA or higher monitor that is capable of 43 line mode.  43 
  283.     line mode allows all circuit description and basic panel      
  284.     information to be examined in a single display area.
  285.  
  286. 5.  A printer capable of printing the graphics character set. 
  287.     (box characters and lines).  The printer should be set to
  288.     EPSON mode with the GRAPHICS character set for dot matrix 
  289.     printers and code page 437 for laser printers.
  290.  
  291. 6.  Expanded memory suggested, but not required. If available PANEL
  292.  
  293.     will use up to 1MB of expanded memory in 16K segments         
  294.     controlled by an EMS driver for the purpose of database       
  295.     buffers. 
  296.  
  297. 7.  Use of mouse is optional. 
  298.  
  299.  
  300.  
  301.  
  302.  
  303.  
  304.                       FILES 
  305.                       ~~~~~ 
  306. You have the following files for the PANEL 2.1 program: 
  307.  
  308. 1.  PANEL.EXE      Main program. 
  309. 2.  PANEL.MDB      Data base file will be created on first start. 
  310. 3.  PANEL.HLP      Help screens. 
  311. 4.  PANEL.DOC      Documentation. 
  312. 5.  PANEL.INI      Initialization file 
  313. 6.  FEEDBACK.DOC   Program feedback. 
  314. 7.  ISAMPACK.EXE   Utility to pack data file. REG-VER 
  315. 8.  ISAMREPR.EXE   Utility to repair a damaged data file. REG-VER 
  316.              
  317.  
  318.  
  319. Copyright (c) 1994  All Rights Reserved        Page 4 
  320. PANEL 2.1  From Electrical Design Software
  321.  
  322.  
  323.  
  324. AVAILABLE SCREEN MODES
  325. ~~~~~~~~~~~~~~~~~~~~~~
  326. Panel will default to 43 line mode,  If a screen mode of 43 or
  327. higher is present when panel is starting panel will not set the
  328. screen itself and will set up in the existing mode. However you can
  329. set the monitor to 50 line mode from the command line with the
  330. following command.
  331.  
  332. *  For 50 line mode type PANEL 50 then press ENTER
  333.  
  334.  
  335.  
  336. PRINTER SETUP
  337. ~~~~~~~~~~~~~
  338.  
  339. 1.  The easiest way to test the printer is to print a circuit 
  340. directory in boxed format. If the report has odd characters the 
  341. printer will need to be set.  For dot matrix printers Check your 
  342. printer manual for setting the printer in epson graphics mode with 
  343. the graphics character set.  If you have a laser printer you need 
  344. to use the symbol set for code page 437.    
  345.  
  346. 2.  Sending the report to a file then using your word processor to
  347. print the reports will eliminate the need to setup the printer.
  348.  
  349. CONTROLLING WINDOWS
  350. ~~~~~~~~~~~~~~~~~~~
  351. Moving windows
  352. ──────────────
  353. * With the keyboard use Ctrl + F7 to activate the window move 
  354.   feature. Use the arrow keys to place the window at the 
  355.   desired location. Press ENTER to set the window in the new 
  356.   location. The cursor must be on the window you want to move
  357.   when using the keyboard method.
  358.  
  359. * With the mouse click the top bar and drag to the desired 
  360.   location.
  361.  
  362. Sizing windows
  363. ──────────────
  364. * With the keyboard use Ctrl + F8 to activate the window size
  365.   feature. Use the up and down arrow keys to change the window    
  366.   size.
  367.  
  368. * With the mouse click the bottom right corner and drag the screen 
  369.   to the desired size.
  370.  
  371.  
  372. Copyright (c) 1994  All Rights Reserved        Page 5 
  373. PANEL 2.1  From Electrical Design Software
  374.  
  375.  
  376.                   PANEL 2.1 TUTORIAL 
  377.                   ~~~~~~~~~~~~~~~~~~ 
  378. Welcome to PANEL - a professional software program        
  379. that is especially designed for Electrical Contractors.
  380. Gain the competitive edge with advanced PC technology and 
  381. individual know-how. 
  382.  
  383. This tutorial is designed to familiarize you with the major
  384. features that PANEL has been widely known for.  You will feel at
  385. ease with these step-by-step instructions.  So lets begin! 
  386.  
  387.  1.  First, start PANEL by going to the directory containing  
  388.      the PANEL files. This may be the default directory   
  389.      PANEL  or any other directory that you may have specified  
  390.      during installation. From that directory type PANEL, then  
  391.      press ENTER.  This will load the program and present the  
  392.      opening screen.  
  393.  
  394.  2.  You can begin this tutorial by pressing the ENTER key or SPACE
  395.  
  396.      BAR. This will access the main work screen. 
  397.      
  398.      Remember to display a help message about the task you are 
  399.      performing, press F1.  To exit help press ESC.  
  400.      
  401.  3.  Let's continue by entering the following information into the 
  402.      record.
  403.  
  404.  EXAMPLE DATA:
  405.                                                                  
  406.   Panel: Main breaker panel      Location: Cellar closet         
  407.                                                                  
  408.    Amps: 100    Volts: 120/208   Phase: 3    Wire: 4   Cir: 6    
  409.  
  410.   Circuit desc        SIZE   #   A B C   #     SIZE    Circuit desc        
  411.                   
  412.   Lighting             15    1           2      15     Lighting            
  413.                     
  414.   Plugs                15    3           4      15     Plugs               
  415.                                                                    
  416.   Plugs                15    5           6      15     Plugs               
  417.                                                                  
  418.  
  419. 4.  Now is a good time to discuss a few of the conditions that    
  420.     produce a customized report. 
  421.  
  422.  
  423. Copyright (c) 1994  All Rights Reserved        Page 6 
  424. PANEL  2.1  From Electrical Design Software
  425.    
  426.   A.  Each report will print a panel schedule sized to the number 
  427.       in the circuits field.  Having 24 in the circuits field will
  428.       print a 24 circuit directory. 
  429.  
  430.   B.  You have the option to setup panel to print the buss bars. 
  431.       This option is selected by toggling the menu item under    
  432.       reports. Any change will be saved between sessions.
  433.  
  434.   C.  The name, location, amps, volts, phase, wire & circuits   
  435.       fields are considered required information and will print 
  436.       on all reports along with circuit description and size.  
  437.  
  438.   D.  All other information will only print if information is   
  439.       placed in the field.  For EXAMPLE:
  440.  
  441.      The entire line representing Cond, Fed from & Raceway will 
  442.      be inserted into the top section of the report if any     
  443.      information is in any one of the three fields. The same is   
  444.      so for the Mfg, Brk type & RMS,AIC line as well as the       
  445.      Mount, Main & ground line.
  446.  
  447.  E.  Headers will print only on the reports that also print the 
  448.      prepared for and prepared by information.
  449.  
  450.  F.  A footer will print at the bottom of a report. 
  451.  
  452. 6.  Continue by pressing the Alt + S keys or click the screen     
  453.     command button to access the names screen. Fill in the prepared 
  454.     for and prepared by information. 
  455.  
  456. 7.  Press the Esc key once or press Alt + S or click the Screen   
  457.     command button to return to the main work screen.  Let's print 
  458.     4 reports one of each kind.
  459.  
  460. 8.  TO PRINT A REPORT 
  461.  
  462.     Press ALT to activate the main menu. 
  463.  
  464.     Select Reports, press ENTER. 
  465.       
  466.     Highlight  Directory with - box  press ENTER. 
  467.  
  468.     Accept the default or select your specific printer port, press 
  469.     ENTER.  Your printer is now printing a detailed report. 
  470.     
  471.     Repeat this step for the 3 other types of reports.
  472.  
  473. 9.  Continue by filling in the Cond, Fed from and Raceway fields  
  474.     and print a directory with - box report. 
  475.  
  476. Copyright (c) 1994  All Rights Reserved        Page 7 
  477. PANEL  2.1  From Electrical Design Software
  478.  
  479. 10. Continue by entering information and printing the various types
  480.     of reports.
  481.  
  482. Congratulations!  You have just completed the PANEL 2.1 tutorial. 
  483.  
  484.  
  485. OTHER PRINTING OPTIONS
  486. ~~~~~~~~~~~~~~~~~~~~~~
  487. 1.  Use of the built in options available with most printers.  Many
  488. printers today have a selection of available font style and sizes.
  489. However when selecting a font do not use a font with proportional
  490. spacing, use a font with cpi - characters per inch. Check the
  491. printer manual to set the printer to the font desired, then send
  492. the report to the printer.
  493.  
  494. 2.  Using your word processor.  Send the report to a file then load
  495. that file into your word processor.  If your word processor program
  496. has left and right margins that are less than the with of the
  497. report you should first set your margins wide enough then load the
  498. file.  Once loaded into your word processor you can use all the
  499. printing capability of that program to produce a more enhanced
  500. version of the circuit directory.
  501.  
  502.  
  503. HOW RECORDS ARE DISPLAYED AND FOUND
  504. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  505. 1.  As the number of records increase, the ability to quickly find 
  506.     a specific records will become more important.  Records are   
  507.     displayed in an ascending order based on the current index.   
  508.     The default index when PANEL is started is the NAME field of  
  509.     the main work screen.  Therefore we can go from record to     
  510.     record by: 
  511.  
  512.     A. Select the Next command button to go to the next record and 
  513.        the Prev command button to go to the previous record.
  514.  
  515.     B. Select the Find command button to bring up a dialogue box.
  516.        Enter the search criteria. EXAMPLE: Type  Main panel then  
  517.        press  ENTER. This will go to the record with the word Main 
  518.        panel in the Name field or the record with the next closest
  519.        match.
  520.  
  521.     C. Search for a record with a list box by pressing F2 or select
  522.        search records in the top menu. Pressing a letter with the
  523.        search box displayed will jump to the first record starting 
  524.        with that letter.
  525.  
  526.     D. When the cursor is on the Name field press Page Up to go to 
  527.        the previous record and Page Down to go to the next record.
  528.  
  529. Copyright (c) 1994  All Rights Reserved        Page 8 
  530. PANEL 2.1  From Electrical Design Software
  531.  
  532.  
  533.  
  534.  
  535.              SPECIAL KEYS 
  536.              ~~~~~~~~~~~~ 
  537. PANEL 2.1 uses the following operating functions. 
  538.  
  539. 1.   ENTER         -  Accept input & advance to the next field.  
  540.  
  541. 2.   TAB           -  Advance to the next field. When in a help   
  542.                       window pressing tab will jump from one hyper- 
  543.                       link to the next. 
  544.  
  545. 3.   SHIFT + TAB   -  Move to the previous field. 
  546.  
  547. 4.   ALT           -  Activate the top Menu. 
  548.  
  549. 5.   ALT + HOT KEY -  Select menu item or command button.  Hot keys 
  550.                       are highlighted in white. 
  551.  
  552. 6.   ESC           -  Move towards the main screen & out of the   
  553.                       program. 
  554.  
  555. 7.   NAVIGATION    -  Up or down arrows keys. 
  556.  
  557. 8.   PAGE UP       -  When at name, page up will move to the next 
  558.                       record.  
  559.  
  560. 9.   PAGE DOWN     -  When at name, page down will move to the    
  561.                       previous record. 
  562.  
  563. 10.  MOUSE         -  Select any field or button. 
  564.  
  565. 11.  F1            -  Context help. 
  566.  
  567. 12.  Ctrl + F4     -  Close a window. 
  568.  
  569. 13.  Ctrl + F6     -  Activate next window. 
  570.  
  571. 14.  Ctrl + F7     -  Move a window. 
  572.  
  573.  
  574.  
  575.  
  576.  
  577.  
  578.  
  579.  
  580.  
  581.  
  582. Copyright (c) 1994  All Rights Reserved        Page 9 
  583. PANEL 2.1  From Electrical Design Software
  584.  
  585.      QUICK ACCESS KEYS FROM THE MAIN SCREEN  
  586.      ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 
  587. 15.  Ctrl + A      -  Print directory with box
  588.  
  589. 16.  Ctrl + B      -  Print directory with box & header
  590.  
  591. 17.  Ctrl + D      -  Print directory with header but no box
  592.  
  593. 18.  Ctrl + E      -  Print directory only
  594.  
  595. 19.  Ctrl + X      -  Exit Program 
  596.  
  597. 20.  F2            -  Search records on panel name.
  598.  
  599. 21.  Ctrl + P      -  Move to previous record.
  600.  
  601. 22.  Ctrl + N      -  Move to next record.
  602.  
  603. 23.  Ctrl + F      -  Find Record screen. 
  604.  
  605. 24.  Ctrl + C      -  Copy this record into a new record
  606.  
  607. 25.  Ctrl + H      -  Quick access to the Contents Help window.
  608.  
  609. 26.  Ctrl + S      -  Quick access to the Search Help window.
  610.  
  611.                COMMAND BUTTONS MAIN SCREEN 
  612.                ~~~~~~~~~~~~~~~~~~~~~~~~~~~
  613. New Rec...... Create a new record. 
  614.  
  615. Update....... Update the current record. When a record is changed 
  616.               in any way, a message will ask if the program can  
  617.               update the record for you before you exit. 
  618.  
  619. Delete....... Delete the current record. 
  620.  
  621. Previous..... Move to the previous record in the indexing sequence.
  622.  
  623.  
  624. Next......... Move to the next record in the indexing sequence. 
  625.  
  626. Find......... Find a specific record. The search will take place 
  627.               on the field that is the current index. 
  628.  
  629. Screen....... Toggle the Name screen. 
  630.  
  631. Exit......... Exit the program. 
  632.  
  633. Esc.......... The Esc button will move out of the program. 
  634.  
  635. Copyright (c) 1994  All Rights Reserved        Page 10
  636. PANEL 2.1  From Electrical Design Software
  637.  
  638. HELP SYSTEM 
  639. ~~~~~~~~~~~ 
  640. The Help System is a Context Help System and Hyper-Text Help  
  641. System.  Some help screens have Hyper Links that relate to the  
  642. subject in discussion.   
  643.  
  644. F1 =    Pressing the F1 key on any field will bring up context
  645. help.   
  646.   
  647. SELECTING A HELP LINK 
  648. ~~~~~~~~~~~~~~~~~~~~~
  649. With the keyboard Press TAB or Shift-TAB to select a link. 
  650. Press ENTER to accept and go to that subject.
  651.  
  652. With a MOUSE     - Click on phrases outlined by two triangles.  
  653.  
  654. SCROLLING THE HELP WINDOW 
  655. ~~~~~~~~~~~~~~~~~~~~~~~~~ 
  656. With KEYBOARD    - press the cursor navigation keys. 
  657.  
  658. With a MOUSE     - click on the horizontal or vertical scroll bars.
  659.  
  660. CLOSING THE HELP WINDOW 
  661. ~~~~~~~~~~~~~~~~~~~~~~~ 
  662. With KEYBOARD    - Press Esc or Ctrl-F4. 
  663.  
  664. With a MOUSE     - Double click on the window's control box icon. 
  665.                    top left. 
  666.  
  667. Contents         - Displays a Table of Contents for the           
  668.                    application's HELP. Press C to select Contents. 
  669.  
  670. Search           - Opens a dialogue box that lists all available  
  671.                    HELP topics.  Select a topic from the list box 
  672.                    and press  ENTER. Press S to select Search. 
  673.  
  674. Back             - Jumps to the last HELP topic viewed. Press B to 
  675.                    select Back. 
  676.         
  677. History          - Lists the last 20 HELP topics viewed. Jump to a 
  678.                    topic by selecting from the list box and       
  679.                    pressing  ENTER. Press T to select History. 
  680.  
  681. Copy             - Copies the contents of the current HELP topic  
  682.                    into an edit area. Select the text you want    
  683.                    copied to the Clipboard and choose Copy.       
  684.                    Choosing Copy without selecting any text in the 
  685.                    edit area copies the entire HELP topic to the  
  686.                    Clipboard. Press P to select Copy.             
  687.  
  688. Copyright (c) 1994  All Rights Reserved        Page 11
  689. PANEL 2.1  From Electrical Design Software
  690.  
  691.      GENERAL OVERVIEW OF THE MAIN MENU SELECTIONS 
  692.      ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 
  693.  
  694. REPORTS
  695. ~~~~~~~ 
  696. Directory with box.......  Print a circuit directory with each    
  697.                            description in a boxed area.
  698.  
  699. Directory with box and...  Print a circuit directory with each    
  700. header information         description in a boxed area + the      
  701.                            prepared for, prepared by, headers &   
  702.                            footer information also.
  703.  
  704. Directory with name and..  Print a circuit directory with the     
  705. header - no box            prepared for, prepared by, headers &   
  706.                            footer information. 
  707.  
  708. Directory only no name,..  Print a circuit directory only.
  709. no header, no box         
  710.  
  711. Configured to print......  Give panel the ability to print or not 
  712. buss bar on reports        to print buss bars. When you make a    
  713.                            selection it will be saved between     
  714.                            sessions.
  715.  
  716. Print Field Form ........  Print a form in the boxed format that  
  717. with box                   can be used  to collect information in 
  718.                            the field. 
  719.  
  720. Print Field Form ........  Print a form that can be used to collect
  721. no box                     information in the field. 
  722.  
  723. Exit.....................  Exit PANEL. 
  724.  
  725.  
  726. DATA BASE 
  727. ~~~~~~~~~ 
  728. Search on panel name.....  Display a search list box with the
  729.                            index automatically set to panel name.
  730.  
  731. Set Index to Panel name..  Index records on the Panel name field. 
  732.  
  733. First Record.............  Make the first record current. 
  734.  
  735. Last Record..............  Make the Last record current. 
  736.  
  737. Create New Record........  Create a new record. 
  738.  
  739. Update...................  Update the current record.  
  740.  
  741. Copyright (c) 1994  All Rights Reserved        Page 12 
  742. PANEL  2.1  From Electrical Design Software
  743.  
  744. Delete...................  Delete the current record. 
  745.                            indexing sequence. 
  746.  
  747. Previous.................  Move to the previous record in the  
  748.  
  749. Next.....................  Move to the next record in the indexing 
  750.                            sequence. 
  751.  
  752. Find.....................  Find a specific record. The search will 
  753.                            take place on the field that is the  
  754.                            current index. 
  755.  
  756. Copy this record to a....  Create a new record having all the
  757. new record                 information contained in the current   
  758.                            record
  759.  
  760. HELP 
  761. ~~~~ 
  762. Contents ................  Various help topics. 
  763.  
  764. Search ..................  Sort the help links in alphabetical    
  765.                            order. 
  766.  
  767. Special Keys ............  Screen navigation and functions. 
  768.  
  769. Using Help ..............  Explains about the help system. 
  770.  
  771. About ...................  Information about this program. 
  772.  
  773.  
  774. EACH DATA ENTRY FIELD MAIN SCREEN EXPLAINED 
  775. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 
  776.  
  777. NAME 
  778. ~~~~
  779. Use the Name field to identify information on the main screen.
  780. The Name field is the only indexing field for the main screen.
  781.  
  782. When the cursor is on the Name field you can move to the 
  783. previous record by pressing Page UP or move to the next 
  784. record by pressing page Down.
  785.  
  786. LOCATION
  787. ~~~~~~~~
  788. Used to describe the location of the panel.  
  789.  
  790. AMP
  791. ~~~
  792. The ampere rating of the panel.
  793.  
  794. Copyright (c) 1994  All Rights Reserved        Page 13 
  795. PANEL  2.1  From Electrical Design Software
  796.  
  797. VOLT
  798. ~~~~
  799. The voltage of the system.
  800.  
  801. PHASE
  802. ~~~~~
  803. Single or three phase system. Also used to configure the buss bars.
  804. If no value is inserted into the phase field it will automatically
  805. default to 3.
  806.  
  807. WIRE
  808. ~~~~
  809. Generally 3 wire or 4 wire systems.
  810.  
  811. CIRCUITS
  812. ~~~~~~~~
  813. Panel will accept up to 42 circuits. The number entered in the
  814. circuits will be used to size the reports.
  815.  
  816. COND
  817. ~~~~
  818. List the conductors size and type feeding the panel. 
  819.  
  820. FED FROM
  821. ~~~~~~~~
  822. Where if the panel being fed from.
  823.  
  824. RACEWAY
  825. ~~~~~~~
  826. The raceway or cable type that the panel is being feed with.
  827.  
  828. MFG
  829. ~~~
  830. The Panel manufacture.
  831.  
  832. BRK-TYPE
  833. ~~~~~~~~
  834. The breaker type such as plug in or bolt on. 
  835.  
  836. RMS,AIC
  837. ~~~~~~~
  838. The AIC rating of the circuit breakers.
  839.  
  840.  
  841.  
  842.  
  843.  
  844.  
  845.  
  846.  
  847. Copyright (c) 1994  All Rights Reserved        Page 14 
  848. PANEL  2.1  From Electrical Design Software
  849.  
  850. CIRCUIT DESCRIPTION
  851. ~~~~~~~~~~~~~~~~~~~
  852. Description of each circuit.
  853.  
  854. AMP
  855. ~~~
  856. Ampere rating for this circuit.
  857.  
  858. EACH DATA ENTRY FIELD NAME/INFORMATION/NOTES SCREEN EXPLAINED 
  859. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 
  860. PREPARED FOR INFORMATION
  861. The Name, City, State & Zip fields are indexing fields. 
  862.  
  863. To change the index to the prepared for name, select set 
  864. index to Name from the top menu.
  865.  
  866. When the cursor is on the prepared for field you can move to 
  867. the previous record by pressing Page UP or move to the next 
  868. record by pressing page Down.
  869.    
  870. The default index is the Name field of the main work screen. 
  871.  
  872. PREPARED BY INFORMATION
  873. This information will print on all reports under the prepared
  874. by heading.  If the Prepared by NAME field is empty no prepared
  875. by information or heading will print on the report.
  876.  
  877. HEADERS AND FOOTERS
  878. If a header has any information it will print near the top
  879. of all reports. The header is an excellent location to list 
  880. a description or purpose of the report.
  881.  
  882. If a footer has any information it will print near the bottom
  883. of all reports.
  884.  
  885. MOUNT
  886. Mounting method used - Surface - Flush
  887.  
  888. MAIN 
  889. Information about the main breaker or fuses
  890.  
  891. GROUND
  892. Any grounding information.
  893.  
  894. PANEL NOTES
  895. This area is for the program operator only. information in the
  896. notes field will not print on any reports.
  897.  
  898.  
  899.  
  900. Copyright (c) 1994  All Rights Reserved        Page 15 
  901. PANEL  2.1  From Electrical Design Software
  902.  
  903.             DATA BASE SUBJECTS
  904.             ~~~~~~~~~~~~~~~~~~
  905. DATA BASE INDEXING
  906.  
  907. PANEL has 5 Indexing fields. 
  908. * Panel Name     * Prepared for Name   * Prepared for State
  909.                  * Prepared for City   * Prepared for Zip
  910.  
  911. Records are sorted in an ascending order based on the current 
  912. indexing field. The default index when PANEL is started is 
  913. the NAME field of the main work screen. To change the index 
  914. select the desired index from the Names screen menu.
  915.  
  916. Four of the five indexes also have multiple sub indexes. 
  917.  
  918. * Prepared for Name  > Panel name > City 
  919. * Prepared for State > Name > City
  920. * Prepared for City  > Name > State
  921. * Prepared for Zip   > Name > City
  922.  
  923. Example: The name index will sort based on the name field
  924.          first, then as sub-index it will sort on Panel name  
  925.          and lastly on state.
  926. -----------------------------------------------------------------
  927.  
  928. DATA BASE
  929. All records can be saved to disk in a data base file named
  930. PANEL.MDB. The data base will first show records on an 
  931. ascending order based on the Name field of the main screen. 
  932. -----------------------------------------------------------------
  933.  
  934. DATABASE PACKING UTILITY 
  935. ISAMPACK purges records marked for deletion and recovers disk
  936. space formerly used by deleted records in 32K blocks.
  937.  
  938. When a record is deleted it is removed from the indexing order.
  939. However the information remains in the data file. Using ISAMPACK 
  940. reconstructs the data file with active records only.
  941.  
  942. Syntax     ISAMPACK  PANEL.MDB
  943. -----------------------------------------------------------------
  944.  
  945. DATABASE REPAIR UTILITY
  946. ISAMREPR recovers databases that become corrupted; it recreates 
  947. them by systematically evaluating every table and index and using
  948. every piece of internally consistent information in the file.
  949.  
  950. Syntax     ISAMREPR  PANEL.MDB
  951.  
  952.  
  953. Copyright (c) 1994  All Rights Reserved        Page 16 
  954. PANEL  2.1  From Electrical Design Software
  955.  
  956.  
  957. MAXIMUM FIELD LENGTH
  958.  
  959. The Maximum Field Lengths for the various fields is the data
  960. that will be saved in the data base record. If you type in a 
  961. longer amount of information it will not be saved in the data 
  962. base file PANEL.MDB
  963.  
  964.  PANEL NAME.............24
  965.  LOCATION...............24
  966.  AMP.....................4
  967.  VOLT...................10
  968.  PHASE...................1
  969.  WIRE....................1
  970.  CIRCUITS................2
  971.  
  972.  MFG....................14
  973.  TYPE...................15
  974.  RMS,AIC................12
  975.  
  976.  COND...................14
  977.  FED FROM...............15
  978.  RACEWAY................12
  979.  
  980.  CIRCUIT DESCRIPTION....22
  981.  AMP.................... 6
  982.  
  983.  PREPARED FOR NAME .....25
  984.  PREPARED FOR ADDRESS ..25
  985.  PREPARED FOR CITY .....20
  986.  PREPARED FOR STATE ....20
  987.  PREPARED FOR ZIP ......10
  988.  
  989.  PREPARED BY NAME ......25
  990.  PREPARED BY ADDRESS ...25
  991.  PREPARED BY CITY ......20
  992.  PREPARED BY STATE .....20
  993.  PREPARED BY ZIP .......10
  994.  
  995.  HEADER ONE ............72 
  996.  HEADER TWO ............72
  997.  FOOTER ................72     
  998.  
  999.  MAIN...................15
  1000.  MOUNTING...............14
  1001.  GROUND.................12 
  1002.  NOTES..................72
  1003.  
  1004.  
  1005.  
  1006. Copyright (c) 1994  All Rights Reserved        Page 17 
  1007. PANEL 2.1  From Electrical Design Software
  1008.  
  1009.  
  1010.           REPORTING - PRINT OR FILE
  1011.           ~~~~~~~~~~~~~~~~~~~~~~~~~
  1012.  
  1013. All reports can be sent to
  1014. ~~~~~~~~~~~~~~~~~~~~~~~~~~
  1015. *  Printer ports LPT1, LPT2 or LPT3
  1016. *  An ASCII file via a user supplied name.
  1017.  
  1018. When sending reports to the printer you also have the option
  1019. to produce multiple copies from 1 - 10 with the copies field.
  1020.  
  1021. When sending a report to file PANEL produces an ASCII file
  1022. that you can edit with any word processor. If the default 
  1023. left and right margins of your word processor are less than 
  1024. the width of the report it may be necessary to set the 
  1025. margins to accept the with of the report.
  1026.  
  1027. * With replace PANEL will first check if the user supplied  
  1028.   file name already exist. If so a message box will confirm
  1029.   that you want to continue and overwrite the existing file  
  1030.   or cancel the operation.
  1031.  
  1032. * With append if the file already exist PANEL will add the 
  1033.   report to the end of the existing file otherwise a new file 
  1034.   will be created. A convenient way to use append is to 
  1035.   produce multiple report all into the same file.             
  1036.  
  1037.   PANEL will produce the following types of reports:
  1038.  
  1039. * Directory with - box
  1040. * Directory with - box + name & header
  1041. * Directory with - name & header no box
  1042. * Directory only - no name, header or box
  1043. * Standard field form
  1044. * Boxed field form
  1045. -----------------------------------------------------------------
  1046.  
  1047.  
  1048.  
  1049.  
  1050.  
  1051.  
  1052.  
  1053.  
  1054.  
  1055.  
  1056.  
  1057.  
  1058.  
  1059. Copyright (c) 1994  All Rights Reserved        Page 18 
  1060. PANEL 2.1  From Electrical Design Software
  1061.  
  1062.                   
  1063.                   
  1064.                   SUPPORT
  1065.                   ~~~~~~~
  1066. Support for PANEL 2.1 is FREE please use any 
  1067. method you want. 
  1068.  
  1069. When you call for support have available:
  1070.  
  1071. 1. Your Company or Name as displayed on the opening screen. 
  1072.  
  1073. 2. The name of the program.
  1074.  
  1075. 3. The version of the program.
  1076.  
  1077.  
  1078.  
  1079. BY PHONE: 
  1080. Monday through Friday 9:00 AM to 5:PM Eastern Standard time call
  1081. (603)-893-9008 if we are not available at the time of your call 
  1082. please leave a message, your name, phone number & a good time to 
  1083. call back.
  1084. -----------------------------------------------------------------
  1085.  
  1086.  
  1087. BY FAX: 
  1088. 24 hours a day 7 days a week call 603-893-9008
  1089. -----------------------------------------------------------------
  1090.  
  1091.  
  1092. BY MAIL: 
  1093. Send to:    Electrical Design Software
  1094.             12 Vassar Drive 
  1095.             Pelham, NH 03076
  1096.             United States of America 
  1097.             Attn: Customer Support
  1098.  
  1099.  
  1100.  
  1101.  
  1102.  
  1103.  
  1104.  
  1105.  
  1106.  
  1107.  
  1108.  
  1109.  
  1110.  
  1111.  
  1112. Copyright (c) 1994  All Rights Reserved        Page 19   
  1113.