  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7. Network Working Group                        John M. McQuillan
  8. Request for Comments # 406                   Bolt Beranek and Newman
  9. NIC # 12111                                  10 October 1972
  10. Categories B.1
  11. Updates RFC # 381
  12.  
  13.  
  14.                     Scheduled IMP Software Releases
  15.                     -------------------------------
  16.  
  17.  
  18.      This note is a reminder that the procedures suggested in
  19. RFC # 381 for scheduling IMP software maintenance have now
  20. been in effect for a period of about two months.  Two points
  21. apparently require re-emphasis:
  22.  
  23.  
  24.      1)   We reserve the hour from 7 to 8 a.m. eastern time
  25. every Tuesday as the time when IMPs can be reloaded.  We will
  26. probably not use this period every Tuesday, but we do reserve
  27. this period every Tuesday.  The software maintenance time period
  28. is in addition to the hardware preventive maintenance scheduled
  29. at each site.
  30.  
  31.  
  32.      2)   We now send an IMP - Going - Down message to all
  33. the Hosts at the site which contains information on the time
  34. that the IMP is going down, the expected duration, and the
  35. reason.  We try to send out this message an hour before soft-
  36. ware releases, and five to ten minutes before scheduled pre-
  37. ventive maintenance.  Further, we will also notify the Hosts
  38. at a site, whenever possible, when it is necessary to stop the
  39. IMP on an unscheduled basis.  Finally, 30 seconds before the
  40.  
  41.  
  42.  
  43.  
  44.  
  45.  
  46.  
  47.  
  48.  
  49.  
  50.  
  51.  
  52.  
  53.  
  54.  
  55.  
  56.  
  57.  
  58.                                                                 [Page 1]
  59.  
  60. IMP goes down, a second IMP - Going - Down message will be
  61. sent to the Hosts informing them that the IMP is going down
  62. immediately.  The format of the IMP - Going - Down message
  63. is as follows:
  64.  
  65. bits 1 - 4  -  all zero
  66.  
  67. bits 5 - 8  -  0010
  68.  
  69. bits 9 - 16 -  all zero
  70.  
  71. bits 17 - 32 -  coded as follows:
  72.  
  73.  
  74.           All bits zero - going down in 30 seconds
  75.  
  76.  
  77.  
  78.           Bits 17, 18 = 01 - scheduled hardware PM
  79.  
  80.           Bits 17, 18 = 10 - scheduled software reload
  81.  
  82.           Bits 17, 18 = 11 - emergency reload on restart
  83.  
  84.  
  85.  
  86.           Bits 19 - 22 - how soon the IMP is going down,
  87.                          in 5 minute units.
  88.  
  89.  
  90.  
  91.           Bits 23 - 32 - how long the IMP will be down, in
  92.                          5 minute units.
  93.  
  94.  
  95.  
  96.  
  97.  
  98.     [ This RFC was put into machine readable form for entry ]
  99.     [ into the online RFC archives by BBN Corp. under the   ]
  100.     [ direction of Alex McKenzie.                      1/97 ]
  101.  
  102.  
  103.  
  104.  
  105.  
  106.  
  107.  
  108.  
  109.  
  110.  