  1.        
  2.                   GAS-OIL SEPARATOR FLASH CALCULATIONS
  3.  
  4.          The following is a set of input data as you will see it
  5.     when you load program COPES.EXE.  The numbers are input as 
  6.     they are shown.  These numbers will give you a set of output as 
  7.     shown in the included program called RESULTS.  The input 
  8.     data is loaded interactively as shown by each question.          
  9.     After all of the input data is loaded, the program runs and the 
  10.     output is written to the disk.
  11.  
  12. INPUT MOLE FRACTION CARBON DIOXIDE:
  13. .0015
  14. INPUT MOLE FRACTION HYDROGEN SULFIDE:
  15. .0000
  16. INPUT MOLE FRACTION NITROGEN:
  17. .01060
  18. INPUT MOLE FRACTION METHANE:
  19. .53220
  20. INPUT MOLE FRACTION ETHANE:
  21. .11730
  22. INPUT MOLE FRACTION PROPANE:
  23. .07000
  24. INPUT MOLE FRACTION ISOBUTANE:
  25. .01830  
  26. INPUT MOLE FRACTION N-BUTANE:
  27. .02500
  28. INPUT MOLE FRACTION ISOPENTANE:
  29. .01150
  30. INPUT MOLE FRACTION N-PENTANE:
  31. .01330
  32. INPUT MOLE FRACTION HEXANES:
  33. .01360
  34. INPUT MOLE FRACTION HEPTANES PLUS:
  35. .18670
  36. INPUT SPECIFIC GRAVITY HEPTANES PLUS:
  37. .8168
  38. INPUT MOLECULAR WEIGHT HEPTANES PLUS (LBS  /(LB*MOLE)):
  39. 185.0
  40. INPUT NUMBER OF SEPARATORS (LIMIT 10):
  41. 3
  42. INPUT STAGE       1 SEPARATOR PRESSURE     (PSIA): 
  43. 800
  44. INPUT STAGE       1 SEPARATOR TEMPERATURE  (DEG.F):
  45. 100
  46. INPUT STAGE       2 SEPARATOR PRESSURE     (PSIA):
  47. 61 
  48. INPUT STAGE       2 SEPARATOR TEMPERATURE  (DEG.F):
  49. 100
  50. INPUT STAGE       3 SEPARATOR PRESSURE     (PSIA):
  51. 11
  52. INPUT STAGE       3 SEPARATOR TEMPERATURE  (DEG.F):
  53. 60
  54. INPUT RESERVOIR PRESSURE (PSIA)
  55. 4130.00
  56. INPUT RESERVOIR TEMPERATURE (DEG.F):
  57. 174.00
  58. INPUT STANDARD PRESSURE:  (PSIA)
  59. 14.73
  60. INPUT STANDARD TEMPERATURE  (DEG.F)
  61. 60.00
  62. STOP - PROGRAM TERMINATED. 
  63.  
  64.          After the last data is entered (temperature), the program
  65.      automatically runs and puts the output in a file called RESULTS.
  66.      If you want a hard copy it will be necessary to run a screen 
  67.      print from the disk file (type RESULTS).
  68.  
  69.          The fortran code is included in the event you wish to
  70.      recompile the program.
  71.  
  72.  
  73.  disk file (type RESULTS).
  74.  
  75.          The fortran code is included in the event you wish to
  76.      recompile the program.
  77.  
  78.