  1.  
  2.  GASWELL ORIFICE METER/PROVER/CHOKE CALCULATION PROGRAM DESCRIPTION
  3.  ------------------------------------------------------------------
  4.  
  5.  
  6.  PURPOSE: TO CALCULATE GAS FLOW RATES FROM ALL POSSIBLE SOURCES OF
  7.           GAS MEASUREMENT DATA.
  8.  
  9.  OPTIONS: (1) RATES FROM ORIFICE METER DATA INCLUDING BOTH PIPE
  10.               TAPS AND FLANGE TAPS
  11.           (2) RATES FROM L-10 SQUARE ROOT CHARTS
  12.           (3) RATES FROM CRITICAL FLOW PROVER DATA
  13.           (4) RATES FROM POSITIVE CHOKES
  14.  
  15.  INPUT:   GAS GRAVITY
  16.           DIAMETER OF FLOW STRING (INCHES)
  17.           ORIFICE DATA (PRESSURE, DIFFERENTIAL, TEMP, COEFFICIENT)
  18.           PROVER  DATA (PRESSURE, TEMPERATURE, COEFFICIENT)
  19.           CHOKE   DATA (PRESSURE, TEMPERATURE, COEFFICIENT)
  20.  
  21.  OUTPUT:  FLOW RATE IN MCFD
  22.  
  23.  USES:    (1) TO CALCULATE GAS RATES FROM METER CHARTS
  24.           (2) TO CALCULATE GAS RATES FROM FIELD COLLECTED DATA
  25.           (3) TO CALCULATE GAS RATES FROM DAILY GAUGE REPORTS
  26.           (4) TO AUDIT RATES FROM PIPELINE PURCHASER STATEMENTS
  27.  
  28.  TABLES OF COEFFICIENTS FOR ALL OPTIONS ARE PROVIDED WITH THE
  29.  SOFTWARE.  THIS INCLUDES:
  30.  
  31.           (1) BASIC ORIFICE FACTORS FOR FLANGE TAPS (ADAPTED FROM
  32.               AMERICAN GAS ASSOCIATION GAS MEASUREMENT COMMITTEE
  33.               REPORT NO. 3
  34.  
  35.           (2) BASIC ORIFICE FACTORS FOR PIPE TAPS (ADAPTED FROM
  36.               AMERICAN GAS ASSOCIATION GAS MEASUREMENT COMMITTEE
  37.               REPORT NO. 3
  38.  
  39.           (3) BASIC CRITICAL FLOW PROVER FACTORS FOR BOTH TWO-INCH
  40.               PROVERS AND FOUR-INCH PROVERS
  41.  
  42.           (4) BASIC POSITIVE CHOKE FACTORS FOR BOTH SIX-INCH CHOKE
  43.               NIPPLE AND THORNHILL-CRAVER POSITIVE CHOKE
  44.  
  45.           (5) A TABLE IS ALSO PROVIDED TO ESTIMATE NON-CRITICAL FLOW
  46.               RATES FROM CHOKES AND PROVERS
  47.  
  48.  ADDITIONAL DOCUMENTATION IS INCLUDED WITHIN THE PROGRAM AS ONE OF
  49.  THE MAIN MENU OPTIONS.